321815_1E-1

MSB System Heating cable MSB TPC ■ Can be used in temperature class T4 in Ex area ■ Can be cut to length at random thanks to Its parallel circuit configuration ■ Simple Installation thanks to Its high flexibility and favourable dimensions ■ Corrosion-proof and resistant to chemical attack thanks to Its protective TPC outer jacket Self-limiting parallel heating cable 1. Conductors: stranded copper busbars 2. Self-limiting heating element 3. Electrical insulation jacket: TPC 4. Tinned copper braiding A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating cable. This output regulation Is carried out automatically along the entire length of the heating cable according to the prevailing ambient temperature. As the ambient temperature rises, the heat output of the cable is reduced. This self-limiting property prevents overheating. The heating tape shall not be mounted crossed or overlapped to keep in the temperature class. The heating tape shall not be In operation over the maximum work-piece temperature to ensure the temperature class. A safety temperature limiter Is Thanks to the parallel power supply the heating cable can be cut to any required length. This feature considerably simplifies project planning and In- stallation. The heating cable is cut and terminated In accordance with the local requirements directly on the construction site. In cases where the cable may become damaged, It Is not necessary to replace the whole circuit but only the affected part. BARTEC MSB Is available In different versions and with different power outputs.

 Open the catalog to page 1
321815_1E-2

MSB System Heating cable MSB TPC MSB with thermoplastic elastomere protective jacket ■ fatigue resistance for long life time at low and high temperatures ■ resistance to oil, greases and many chemicals Explosion protection Ex protection type heating tape Verification certification system Priifbescheinigung heating cable Max. resistance of protective braid with protective braid and protective outer Heat output on insulated steel pipes at 230 V under nominal conditions.

 Open the catalog to page 2
321815_1E-3

MSB System Heating cable MSB TPC Permissible ambient temperature Max. permissible heating cable temperature Cut-in heating cable +110 °C Cut-off heating cable +130 °C

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.