Description: The PSBL system heating cable consists of two tin-coated stranded copper wires with a cross-section of 1 mm² each, positioned in parallel. An irradiated electrically conducting plastic is extruded over these wires, which adjusts its heating output based on ambient temperature changes. The cable is protected by two insulation jackets, with additional protection from copper braiding and a flame-retardant, UV-resistant plastic jacket.
Features:
  • Self-limiting heating output.
  • Usable in explosive atmospheres without a temperature limiter.
  • Can be cut to any length due to parallel power circuit configuration.
  • External protective sheath resists corrosion and chemical influences.
  • Tin-coated copper braiding provides electrical and mechanical protection.
  • Flexible and easy to install, with on-site cutting and terminating possible even in Ex areas.
Technical Specifications:
  • Dimensions: 10.5 x 6.0 mm
  • Minimum bend radius: 25 mm
  • Permissible ambient temperature: Cut-in +65 °C, Cut-off +85 °C
  • Minimum installation temperature: -55 °C
  • Supply voltage: AC 208 V to 254 V, AC 110 V to 120 V
  • Protective braid resistance: < 18.2 Ω/km
  • Explosion protection: Ex protection type II 2G Ex e II T5, T6; II 2D Ex tD A21 T 95 °C, T 80 °C
  • Certifications: KEMA 08 ATEX 0112, IECEx KEM 09.0085
Areas of Application:
  • PSBL with polyolefin insulation jacket: Suitable for exposure to aqueous, inorganic chemicals and high mechanical requirements.
  • PSBL with fluoropolymer protective jacket: Suitable for high humidity, organic chemicals, and high mechanical requirements.
Performance Data: The document includes detailed tables showing maximum lengths of heating circuits at various temperatures and power settings, as well as heat output on insulated steel pipes at 230 V under nominal conditions.
Selection Chart: Provides order numbers for different types of PSBL cables with either fluoropolymer or polyolefin protective jackets, suitable for various voltage and protection requirements.
See more

Catalog excerpts

246903_1E-1

PSBL System Heating cable PSBL Can be used in explosive athmospheres without temperature limiter power circuit configuration ■ External protective sheath for resistance to corrosion and chemical influences Tin-coated copper braiding for electrical ■ Easy installation due to high level of ■ Easy on-site cutting and terminating, with silicone cold applied technology even 1. Conductors: stranded copper busbars 2. Self-limiting irradiated synthetic polymer heating cable 3. Inner polyolein electrical insulation jacket thermally fused to the heating element (bonded jacket) 4. Outer polyolefin electrical insulation jacket 5. Tinned copper braiding Via two tin-coated stranded copper wires with a cross-section of 1 mm2 each which are positioned In parallel, an irradiated electrically conducting This electrically conducting plastic matrix responds to changes of the ambient temperature with a respective increase or decrease of the heating output. Electrical strength as well as protection against humidity and mechanical stress is ensured by two surrounding insulation jackets, whereas the first jacket is permanently bonded to the heating matrix (bonded jacket). Additional electrical and mechanical protection Is achieved by means of the following copper A flame-retardant, UV-resistive plastic jacket protects the braiding against humidity and offers further protection against major mechanical 6. Protective jacket of fluorpolymer

 Open the catalog to page 1
246903_1E-2

PSBL System Heating cable PSBL PSBL with polyolefin insulation jacket ■ if the heating cable is exposed to aqueous, inorganic chemicals. ■ if high mechanical requirements are set for the cable. PSBL with fluoropolymer protective jacket ■ if the heating cable is exposed to high levels of humidity organic chemicals such as ■ where the cable must meet high mechanical requirements. PSBL characteristics Heat output on insulated steel pipes at 230 V under nominal conditions. Certification System Certification Components protective TFE outer jacket Minimum bend radius Permissible ambient temperature...

 Open the catalog to page 2
246903_1E-3

PSBL System Heating cable PSBL

 Open the catalog to page 3
246903_1E-4

PSBL System Heating cable PSBL Selection chart PSBL

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.