BL675D DUAL BLACKBODY CALIBRATION SOURCE
1Pages

{{requestButtons}}

Catalog excerpts

BL675D DUAL BLACKBODY CALIBRATION SOURCE - 1

BL675D DUAL BLACKBODY CALIBRATION SOURCE SPECIFICATION The BL675D Dual Cavity Blackbody Calibration Source is easy to use, and makes calibration of infrared pyrometers with multiple temperature ranges faster than ever before by combining a hot and cold side in one unit. The calibrators are simple to set and control. Merely input the desired Black Body temperature on the convenient front panel control buttons, let the unit reach the set temperature, wait a few moments to ensure stability, aim, and shoot. The radiated energy from the Black Body is measured by operator's IR thermometer. Compare the IR thermometer reading to the display on the controller and record the difference. Ideal for simple 2-point calibrations. Ultra-High uniformity and stability 0.995 emissivity Fast Heat Up & Cool Down Times Built-in temperature correction function Rugged & Lightweight New Feature: Reference sensor input I Infrared temperature sensors Infrared thermal imaging systems Spectrographic analyzers Spectral radiometers Heat flux meter Balun Technology Co., Ltd Add: 1322, F/3, Bldg 1, 33 Zique Rd, Haidian, Beijing100095, China Temperature range Display resolution Aperture size Distance to target Emissivity Stability (10 min) Uniformity Heat cavity shape Cool down time Heat up time Control method Temperature sensor Power supply Interface Dimension Net weight Low Range High Range -15° C ~ 100℃ 50° C ~ 500° C 0.01° C 0.1° C 65mm 50mm 130mm 160mm Better than 0.995 0.1° C or 0.1%rd (whichever is greater) 0.15° C or 0.15%rd (whichever is greater) End closed tube 30 minutes from ambient to -15℃ 60 minutes from ambient to 500℃ Digital PID controller with readout Precision platinum RTD 220VAC, 850WA (110VAC is optional) RS485 435mm(D) x 390mm(W) x 200mm(H) 15 kg approx. IEC/TS 62492-1-2008:Industrial process control devices - Radiation thermometers. Part 1: Technical data for radiation thermometers ASTM E2847-2013: Standard practice for calibration and accuracy verification of wideband infrared thermometers ASTM E1256-2011a: Standard Test Methods for radiation thermometers (Single waveband type) OIML D24 (1996):Total radiation pyrometers JJG 856-2015: Verification regulation of radiation thermometers BL675D Dual blackbody calibration source Power code (need to confirm the plug type in advance) User manual ORDERING MODEL NUMBER ■ ■

Open the catalog to page 1

All Balun Technology Co. catalogs and technical brochures