Catalog excerpts
BL673 PORTABLE BLACKBODY CALIBRATION SOURCE SPECIFICATION The BL673 is a portable blackbody calibration source utilizing a digital indicating temperature from -20℃ to 125℃ . A precision platinum RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability. The BL673 is as easy to use as “point and shoot.” Simply set the desired blackbody temperature from the convenient front panel control buttons, wait a few minutes for equilibrium, and point the gun at the target. The radiated energy from the blackbody is measured by your IR thermometer. Simply compare its readings to the display on the blackbody and record the difference. Ideal for most of IR Guns! Subzero -20℃ to +125℃ 65 mm aperture diameter end closed tube Emissivity is better than 0.995 Fast Heat Up & Cool Down Times 0.15℃ high temperature stability Light weight yet rugged design for portability Nitrogen purge connection available External reference sensor input Infrared temperature sensors Infrared thermal imaging systems Spectrographic analyzers Spectral radiometers Heat flux meter Balun Technology Co., Ltd Add: 1322, F/3, Bldg 1, 33 Zique Rd, Haidian, Beijing100095, China Temperature range Aperture diameter Heated emitter shape Emissivity Display resolution Control stability (10min) Temperature uniformity Display accuracy Warm up time (ambient temperature < 25℃ ) Control method Temperature sensor Tube depth Power supply Interface Calibration band Dimension Net weight -20℃ to 125℃ 65 mm End closed tube > 0.995 0.01℃ (<100℃ );0.1℃ (>100℃ ) 0.1℃ 0.15℃ 0.5℃ 20 minutes from ambient to 125℃ ; 30 minutes from ambient to -20℃ Digital PID controller with readout Precision Platinum RTD 110mm from entrance to target 220VAC, 350VA (110VAC is option) RS485 8um-14um spectral band 300mm(H)x 200mm(W)x 280mm(D) Approx. 8.3 kg BL673 Portable blackbody calibration source Power cord (need to confirm the plug type in advance) User manual Accredited calibration certificate (P/N: 9000-673) Customize range -23℃ to 155℃ , (P/N: BL673-X) ORDERING MODEL NUMBER ■ ■ IEC/TS 62492-1-2008:Industrial process control devices -Radiation thermometers. Part 1: Technical data for radiation thermometers ASTM E2847-2013: Standard practice for calibration and accuracy verification of wideband infrared thermometers ASTM E1256-2011a: Standard Test Methods for radiation thermometers (Single waveband type) OIML D24 (1996): Total radiation pyrometers JJG 856-2015: Verification regulation of ra
Open the catalog to page 1All Balun Technology Co. catalogs and technical brochures
-
BL765 Humidity Generator
1 Pages