cad

THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION
21Pages

{{requestButtons}}

Catalog excerpts

THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 1

Human Machine Interfaces THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION

Open the catalog to page 1
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 2

Human Machine Interfaces | 3 SMARTLIGHT TOWER LIGHT AND SMARTLIGHT INDICATOR Multi-pupose SmartLight tower light and SmartLight indicator Solutions at the cell level SmartLight tower light for cell level information Pick-to-light indication Point-of-use indication Reduce complexity IO-Link distributed modular I/O Signalling and display devices SmartLight tower light with IO-Link products SmartLight indicator with IO-Link products IO-Link Masters EtherNet/IP, DeviceNet Profinet, Profibus CC-Link, CC-Link ie field EtherCAT, USB Interface 22 IO-LINK MASTERS 28 Accessories – Mounting systems 30...

Open the catalog to page 2
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 3

Human Machine Interfaces | 5 All the information you need at a glance MULTI-PURPOSE SMARTLIGHT TOWER LIGHT AND SMARTLIGHT INDICATOR SmartLight is the first programmable LED tower light. With a rich color spectrum, adjustable light intensity and the ability to program individual configurable segments, the Balluff SmartLight can display various machine or process status information instantaneously. The mode of operation can be switched based on programmed conditions so that a single SmartLight can be used as a multi-function tower light.

Open the catalog to page 3
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 4

Human Machine Interfaces | 7 Solutions at the cell level Process monitoring and machine status at the cell level is an integral part of manufacturing operations. Instantaneous visual feedback enables plants to operate efficiently. SmartLight adds tremendous value to the plant floor as it combines multiple modes of operations and functions in a single programmable tower light. With the SmartLight tower light and SmartLight indicator there are unlimited possibilities! 1 Light and sound indicators nn Programmable intensity and customizable bright colors nn Audible 95db sound modules 2...

Open the catalog to page 4
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 5

Human Machine Interfaces | 9 Flexible, scalable, intelligent tower light for cell level information The SmartLight tower light offers four programmable modes of functionality: segment or stack light, level indication, run light, and flexible mode. Additionally, a SmartLight tower light with a buzzer option is available for audible feedback. STACK LIGHT MODE LEVEL MODE FLEXIBLE MODE SmartLight’s segment or stack light mode is feature-rich compared to a standard stack light. The number of segments and color for each segment can be programmed and changed on demand. Individual segments can be...

Open the catalog to page 5
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 6

10 | Human Machine Interfaces Interfaces Human Machine Interfaces | 11 Flexible, scalable, intelligent pick-to-light indication At the heart of most lean initiatives is the desire for more flexibility with increased productivity. Traditional pick-to-light systems can provide that productivity but fall short on flexibility … until now. The SmartLight indicator with integrated photo electric sensors is the most innovative pick-to-light product available. All the functions from the indicator only unit are available in this unit. Integrated into flow-racks and supermarkets on the manufacturing...

Open the catalog to page 6
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 7

Human Machine Interfaces | 13 Three segments Flexible, scalable, intelligent point-of-use indication The SmartLight indicator line consists of only two parts: an indicator only version and indicator with an integrated photoelectric sensor for Pick-to-Light applications. Both share the same powerful LED indication functions and an IO-Link interface with Balluff’s innovative expansion mode. This expansion mode allows two indicators to be connected to one IO-Link port. The LED indication functions are divided into six unique segments. Each segment can be individually controlled or utilize a...

Open the catalog to page 7
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 8

Human Machine Interfaces | 15 Reduce complexity, reduce risk Generic stack light Reduce complexity Doing more with less is the foundation of our SmartLight product line. With one part number and one standard M12 cable you can fulfill nearly every task in your plant for cell level and point-of-use indication. Reduce complexity One part number ONE PART NUMBER The SmartLight tower light product line is comprised of only six part numbers—three sizes, with or without an audio alarm. That’s it. No need to build your own stack light anymore. One part does it all and much more. No need to terminate...

Open the catalog to page 8
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 9

Human Machine Interfaces | 17 IO-LINK MASTERS nn 4-port and 8-port versions nn Parameter server functionality nn Industrial IoT ready IO-Link distributed modular I/O IO-Link is a fieldbus and manufacturer independent communications standard defined by the international communications standard IEC 61131-9. IO-Link enables seamless integration of a variety of actuators while maintaining scalability for future adaptability in the controls architecture. IO-Link is universal and adaptable to any major industrial network protocol, such as Ethernet/IP, Profinet, EtherCAT, CC-Link IE Field,...

Open the catalog to page 9
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 10

Human Machine Interfaces | 19 SMARTLIGHT TOWER LIGHT WITH IO-LINK WITH SOUND MODULE (BUZZER) WITHOUT SOUND MODULE Number of default segments max. Color spectrum per segment Red, green, yellow, blue, white, orange, user defined Red, green, yellow, blue, white, orange, user defined Red, green, yellow, blue, white, orange, user defined Stack, run, level, flex Stack, run, level, flex Supply voltage Connection: IO-Link IP30 (with buzzer), IP65 (without buzzer) IP30 (with buzzer), IP65 (without buzzer) IP30 (with buzzer), IP65 (without buzzer) Operating/storage temperature 60 × 60 × 330.5 (with...

Open the catalog to page 10
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 11

20 | Human Machine Interfaces Human Machine Interfaces | 21 SMARTLIGHT INDICATOR WITH IO-LINK Color spectrum per segment Red, green, yellow, blue, white Red, green, yellow, blue, white Supply voltage Function indicator IO-Link Green LED or segment 1 (fail safe) Green LED or segment 1 (fail safe) Connection: IO-Link Operating/storage temperature Base housing material Lens material Sensor type Sensor range Cycle time 8.4 ms with IO-Link 1.1 Master 8.4 ms with IO-Link 1.1 Master IO-Link process data length

Open the catalog to page 11
THE FUTURE OF TOWER LIGHTS AND PROCESS VISUALIZATION - 12

Human Machine Interfaces | 23 IO-LINK MASTERS Balluff offers IO-Link master blocks for all major networks and fieldbus protocols. With built-in expandability, IO-Link blocks can significantly increase the I/O count served by a single network node. Each IO-Link port is configurable to be used as either IO-Link or as input or output providing flexibility for scalable and modular controls architecture.

Open the catalog to page 12

All Balluff GmbH catalogs and technical brochures

Archived catalogs

  1. BES00PY

    2 Pages

  2. BES008L

    2 Pages

  3. BES02NC

    2 Pages

  4. BES01ZN

    2 Pages

  5. BES0028

    2 Pages

  6. BES05F9

    2 Pages

  7. BES054Z

    2 Pages

  8. BES0086

    2 Pages

  9. BES0042

    2 Pages

  10. BES013N

    2 Pages

  11. BES00H4

    2 Pages

  12. BES003P

    2 Pages

  13. BES00HC

    2 Pages

  14. BES00CK

    2 Pages

  15. BES01ZW

    2 Pages

  16. BES00EF

    2 Pages

  17. BES00HF

    2 Pages

  18. BES00P7

    2 Pages

  19. BES0068

    2 Pages

  20. BES060T

    2 Pages