RPM III IEC Integral HP DC Motors
132Pages

{{requestButtons}}

Catalog excerpts

RPM III IEC Integral HP DC Motors - 2

Mission Statement To be the best (as determined by our customers) marketers, designers and manufacturers of industrial electric motors, mechanical power transmission products, drives and generators.

Open the catalog to page 2
RPM III IEC Integral HP DC Motors - 3

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP IEC Variable Speed Industrial DC Motors Table of Contents DC Motors – RPM III General Information Motor Features

Open the catalog to page 3
RPM III IEC Integral HP DC Motors - 4

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Introduction IEC DC Motors GENERAL TECHNICAL DATA Ratings: Armature voltage: Field voltage: Insulation class: Ambient temperature: Degree of Protection, Method of Cooling TYPICAL APPLICATION AREAS Metals Industry Mill drives, slitting line, tube mills, coating lines, press feeder drives Textile Industry Spinning, elongation, impregnation, winding and cutting Forest Products Industry Pulp preparation, super calenders, winders, rewinders, paper cutters Printing Industry Rotogravure, offset and letter printing presses Rubber and Chemical Industry...

Open the catalog to page 4
RPM III IEC Integral HP DC Motors - 5

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP General Features Baldor•Reliance integral HP DC motors are based on more than 90 years of Baldor•Reliance motor technology that includes the Super T and the original RPM motor – the first DC motor specifically designed to operate from solid-state rectified power. Built to take on industry’s toughest jobs, RPM III motors have proven themselves through on-thejob performance. Whatever your DC requirements, Baldor•Reliance DC motors are the best investment for your motor dollars to give you dependable DC motor performance for years to come. UNIQUE...

Open the catalog to page 5
RPM III IEC Integral HP DC Motors - 6

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Standard Motor Features This catalog is designed to help motor users quickly select and specify the proper Baldor•Reliance Industrial Direct-Current Motor. Frame size information on standard motors is given on the Frame Size pages. A complete listing and definition of standard motor features is contained in this section. Application requirements beyond the limits of the basic motor will require a modification adder. Modifications are listed immediately following the Dimension Sheets section. The Dimension Sheet and Performance Data Sections contain...

Open the catalog to page 6
RPM III IEC Integral HP DC Motors - 7

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Standard Motor Features the windings at working temperature. (Note that the variation in speed can be above and below rated speed.) kW per 1000 r/min Base Speed Tolerance Not less than 2.5 but below 10 BEARINGS Standard IEC DC motors utilize ball bearings. These bearings and their internal clearances have been especially selected based on load carrying ability, thermal stresses and speed range consistent with ample bearing life. Roller bearings are used for belted duty on frames UGK180-UGK280 per the Modification section. The “U” prefix indicates...

Open the catalog to page 7
RPM III IEC Integral HP DC Motors - 8

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Standard Motor Features LUBRICATION IEC RPM III DC motors have the Patented PLS/Positive Lubrication System developed and tested by Baldor Electric to provide positive motor bearing protection. Open bearing design allows the lubricant to remove heat from the bearing. Standard grease may be used in ambients down to –25°C. MOUNTING Foot and flange mounting in accordance with IEC standards. Motors will operate successfully mounted on the floor, wall or ceiling and with the shaft at any angle from horizontal to vertical. Hand-hole covers can be...

Open the catalog to page 8
RPM III IEC Integral HP DC Motors - 9

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Standard Motor Features TACHOMETER MOUNTING IEC RPM III frames GK132 through GK250 have as a standard feature a provision for mounting an integral AC or DC tachometer. TEST-STANDARD Each motor is given a routine test to determine that it is free from electrical or mechanical defects and to provide assurance that it meets design specifications. This test consists of: (Test data is not supplied to customer without additional charges.) Neutral check Winding resistance Commutation check High potential test No-load test at base speed and maximum field...

Open the catalog to page 9
RPM III IEC Integral HP DC Motors - 10

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP AXIAL THRUST CAPACITY IN KILOGRAMS BLOWER MOTOR RATING FOR MOTOR MOUNTED BLOWERS CROSS REFERENCE BETWEEN IEC AND NEMA NOMENCLATURE ... 13 FILTER ATTACHMENT FOR MOTOR MOUNTED BLOWER –

Open the catalog to page 10
RPM III IEC Integral HP DC Motors - 11

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Technical Description VALIDITY • High output rating per frame size The technical description applies for Frames sizes IEC GK1104GK2810 of RPM III DC motors. • Compact design by square laminated frame • Suitable for high current increase rates due to fully laminated magnetic circuit • Easy operation on static converter power supply Direct current motors are suitable for all types of drives, with or without speed control. • Good commutation on static converter power supply • Extended operation reliability due to class “H” insulation system • Integral...

Open the catalog to page 11
RPM III IEC Integral HP DC Motors - 12

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Technical Description STANDARD MOTOR FEATURES – SUMMARY Refer to GENERAL INFORMATION – page 2 for complete features. Standard guarantees are made on the basis that the motor will operate at an altitude from sea level to 1000 m per IEC 34-1. Refer to Mod. 101 for motors operating at higher altitudes. All machine components such as frame, end plates, bearing caps, shaft, terminal box, etc., are machined on the latest CNC machine tools. This ensures a uniformly high quality standard with very low production tolerances. The motor feet are integral, which...

Open the catalog to page 12
RPM III IEC Integral HP DC Motors - 13

IEC VARIABLE SPEED DC MOTORS INTEGRAL HP Technical Description MAXIMUM SAFE SPEED DC motors are inherently capable of reaching speeds hazardous to personnel and equipment if improperly connected or misapplied. Operation of a shunt wound or compound wound motor without the shunt field energized at the proper current may cause the motor to reach a dangerous speed. Both the motor instruction manual and the control instruction manual must be followed when the motor is being connected and operated and the work must be performed by qualified personnel. All DC motors of the RPM III series are...

Open the catalog to page 13

All Baldor Electric Company catalogs and technical brochures

  1. D-Flex

    2 Pages

  2. CA501

    28 Pages

  3. Maxum XTR

    100 Pages

  4. Tigear 2 Family

    228 Pages

  5. IEC Motors

    16 Pages

  6. Grip Tight

    8 Pages

  7. To be the Best

    16 Pages

Archived catalogs