1. Heat requirement calculation Q = Heat quantity in kJ (Kilojoule) C = Specific heat capacity in kJ/kg K At = Temperature rise (target temperature ■ starting temperature) Q = Heat quantity in kJ (Kilojoule) Value table Heat of fusion (Lf) = kJ/kg Iron (pure) Consta ntan Sulphuric acid Carbon dioxide The efficiency must be considered on the basis of radiation and exhaust air temperature. We cannot assume any guarantee for the correctness of the information in the table! You will only achieve optimal results when using Subject to technical changes.

Open the catalog to page 2
Air Heaters & Blowers - 3

Innovative - practice-oriented efficient Service from 800 Watt to 17400 Watt reliable configuration and dimensions; flexible due to graduated heating units; activation by potentiometer, controller or SPS with and without integrated power unit; with power control system via potentiometer, controller or SPS; configuration of the activation can be modified at every service point multifunctional due to modular layout; modern and functional design Efficient Service reliable service within 24 hours; easy replacement of heating units by the user - Compact design - Completely oil-free - High...

Open the catalog to page 3
Air Heaters & Blowers - 4

Technical data Static pressure Weight incl. cable Conformity marking Standard equipment - Variable temperature setting - Variable air-flow setting - Main switch that can be locked separately for - Integrated tool protection Special version - External controller for heat - External controller for air flow - Analysis of motor speed - Integrated thermocouple - Integrated digital controller Connection flange Wide slot nozzle 150x12 mm Wide slot nozzle 85x15 mm Wide slot nozzle 300x4 mm Stainless steel filter Special accessories and external control are available on request! Equipment with...

Open the catalog to page 4
Air Heaters & Blowers - 5

Air heater Type XS20 from 400 Watt to 2000 Watt 160 (217) 289 (346) 40 M 16 SW 17 Ø 20x0,5 8 35 46 Druckluftanschluss Connection compressed air Push-In Push-in Stecknippel 6mm connection 6 mm Compensation line Ausgleichsleitung for thermocouplefür Mantelthermoelement 1500 mm long PVC 4,0mm 1500mm lang SW 27 Technical data Item No. Voltage Power Frequency Max. temperature Max. air pressure Min. air flow Thermocouple Air connection Air outlet Dimensions Weight Protection class I Marking Anschlussleitung Power cord 3x1,5mm² 2 3 x 1,5 mm Ölflex 7mm 1500 mm long 1500mm lang XS20 V W Hz °C Bar...

Open the catalog to page 5
Air Heaters & Blowers - 6

Technical data Different voltages, power and special versions, such as --- external activation via controller or SPS possible. 5107144 Round nozzle 0 5 mm Available on request! 5107145_Round nozzle 0 10 mm_ Special accessories on request! You will only achieve optimal results when using Subject to technical changes.

Open the catalog to page 6
Air Heaters & Blowers - 7

Technical data Different voltages, power and special versions, such as --- external activation via controller or SPS possible. 5105475 Wide slot nozzle 20x2 mm_ Available on request! 5105526 Wide slot nozzle 40x2 mm_ Special accessories on request! E-Mail info@bak-ag.com

Open the catalog to page 7
Air Heaters & Blowers - 8

Different voltages, power and special versions, such as external activation via controller or SPS possible. Special accessories on request! You will only achieve optimal results when using Subject to technical changes.

Open the catalog to page 8
Air Heaters & Blowers - 9

from 2200 Watt to 6100 Watt 5107270 Wide slot nozzle 150x12 mm Different voltages, power and special versions, such as external activation via controller or SPS possible. Special accessories on request! E-Mail info@bak-ag.com

Open the catalog to page 9
Air Heaters & Blowers - 10

from 5800 Watt to 8600 Watt Technical data 5107259 Wide slot nozzle 150x12 mm_ Different voltages, power and special versions, such as external activation via controller or SPS possible. Special accessories on request! You will only achieve optimal results when using Subject to technical changes.

Open the catalog to page 10
Air Heaters & Blowers - 11

from 5900 Watt to 17400 Watt Technical data 5107274 Wide slot nozzle 130x17 mm_ 5107272 Wide slot nozzle 300x12 mm_ 5107267 Wide slot nozzle 500x15 mm_ Different voltages, power and special versions, such as external activation via controller or SPS possible. Special accessories on request! E-Mail info@bak-ag.com

Open the catalog to page 11
Air Heaters & Blowers - 12

from 3300 Watt to 11800 Watt The small dimensions of the gas-tight air heater en- ables space-saving installation. If one or several heat- ers are connected to the compressed air network, you will receive an air flow with high air speed. The tem- perature can be controlled electronically to 100%. The hot air stream is used in drying processes, soldering processes, etc. Due to the robust design, this device is suitable for the most demanding use. Special features - Gas-tight, pressure-resistant - Reliable protection of heating element due to - Optionally integrated thermocouple - External...

Open the catalog to page 12
Air Heaters & Blowers - 13

High-pressure blower Technical data Side channel blower Inlet port Outlet port Dimensions (Ixwxh) Ambient temperature Motor capacitor 230 V with clamp and cable Hose connection adapter 1 x38/2x38 mm Hose connection adapter 1 x38/2x19 mm In the blowers, a stainless steel filter is standard at the intake connection! Special accessories on request! E-Mail info@bak-ag.com

Open the catalog to page 13
Air Heaters & Blowers - 14

High-pressure blower HD240 3,65 m3/min – 27 000 Pa Technical data Volumetric current m3/min 3,65 4,42 5100200 Total pressure difference Pa 27 000 26 000 Voltage Frequency Current consumption Speed Motor power V 3 x 400 3 x 480 Hz 50 60 A 5,2 5,5 rpm 2900 3500 kW 2,20 2,55 ∅ 60 mm (exterior) ∅ 60 mm (exterior) 397 x 327 x 365 –20 °C to +60 °C IP 54 Accessories Item No. 5107278 5107291 5107293 5107288 5107285 5107286 5107287 14 Side channel blower Noise pressure level LpA (db) 68,8 70,8 Weight kg 26,5 26,5 Total pressure increase ∆p1 → Inlet port Outlet port Dimensions (l x w x h) Ambient...

Open the catalog to page 14
Air Heaters & Blowers - 15

Medium-pressure blower Technical data Centrifugal blower Inlet port Outlet port Dimensions (Ixwxh) Ambient temperature 5110887_Motor capacitor 230 V with clamp and cable Hose connection adapter 1 x60/2x60 mm Hose connection adapter 1 x60/1 x38 mm Hose connection adapter 1 x38/2x38 mm In the blowers, a stainless steel filter is standard at the intake connection! Special accessories on request! E-Mail info@bak-ag.com

Open the catalog to page 15

All BAK Technology Ltd. catalogs and technical brochures

  1. LarOn 21

    1 Pages

  2. PROTON

    1 Pages

  3. belton P

    1 Pages

  4. belton T

    1 Pages

  5. Planon

    1 Pages

  6. Planon-Band

    1 Pages

  7. ERON

    1 Pages

  8. Maron

    1 Pages

  9. Rion Digital

    1 Pages

  10. Rion

    1 Pages

  11. Micon

    1 Pages

  12. Proton

    1 Pages

  13. laron

    1 Pages

  14. Laron H

    1 Pages

  15. BAK-MiOn

    1 Pages

  16. BAK Comon

    1 Pages

  17. BAK Weldon S

    1 Pages

  18. BAK Weldon

    1 Pages

  19. BAK Rion

    1 Pages

  20. TarpOn

    1 Pages

  21. SeOn

    1 Pages

  22. Hot Cleaner

    1 Pages

  23. Compact

    1 Pages

  24. MiOn

    1 Pages

  25. ErOn

    1 Pages

  26. RiOn

    1 Pages

Archived catalogs

  1. BAK Maron

    1 Pages