Recordall Turbo Series Meters 6" and 20"
1 / 4Pages

Catalog excerpts

Recordall Turbo Series Meters 6" and 20" - 1

Recordall® Turbo Series Meters Models 6600 (16") & 10000 (20") DESCRIPTION Recordall Turbo Series meters meet or exceed the most recent revision of AWWA Standard C701 Class II Standards and are available in cast iron for the 16" and 20" meters. Turbo Series meters comply with the lead-free provisions of the Safe Drinking Water Act. Designed for commercial and industrial applications, the Recordall Turbo Series meter is the smart choice for larger facilities including hotels, apartment buildings, irrigation centers and manufacturing and processing plants. You can count on the Turbo Series meter to help reduce your day-to-day maintenance costs, while delivering accurate and efficient performance. Models 6600 and 10000 are designed for 16" and 20" applications. These meters feature: • Direct coupled turbine based on an exclusive “floating rotor” design that reduces bearing friction and associated wear and tear. Low pressure loss for improved system efficiency. Exceptional registration accuracy across low flow rate, normal operating flow rate and maximum continuous operation flow. Permanently sealed, tamper-resistant register. Meters and encoders are compatible with Badger Meter AMR/AMI meter reading systems and other approved reading technologies. Applications: Recordall Turbo Series meters are designed for cold water, commercial and industrial applications where flows are consistent medium to high flows. Applications include hotels, apartment buildings, irrigations centers and manufacturing and processing plants. Turbo Series meters help reduce day-today maintenance costs while delivering accurate and efficient performance. Operation & Performance: Direct magnetic drive is achieved when the magnet carrier is driven by a gear train coupled to the rotor. The gear train consists of two sets of gears connected by a vertical transmission shaft. One gear set is at the magnet carrier, the other is a worm gear set at the rotor shaft. When water flows into the Turbo Series meter measuring element, it contacts the multi-vaned rotor. The resulting rotor rotation is then transmitted by magnetic coupling to a sealed register or encoder. The direct magnetic drive is built to provides a reliable meter-to-registration coupling. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX® tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. Construction: The Recordall Turbo Series meter is constructed in compliance with ANSI and AWWA C701 standards. It consists of the following basic components: meter housing, interchangeable, unitized measuring element and permanently sealed direct reading registers or encoders. The measuring element consists of the transmission coupling, rotor, inlet and outlet straightening vanes with nose cones, and calibration ring assembly. The unique inlet and outlet straightening vanes minimize swirl from piping arrangements upstream as well as downstream. A strainer is recommended to help ensure optimal flow conditioning and protection for the measuring element. Badger Meter offers dual flange plate strainers—sizes 16" and 20"—in fabricated steel To simplify maintenance, the registers or encoders and measuring elements can be removed without removing the meter housing. Interchangeability of certain parts between meters also minimizes spare parts inventory investment. Meter Installation: The meter is designed for installations where flow is in one direction only. Companion flanges for installation of meters on various pipe types and sizes are available in cast iron as an option. See the Recordall Turbo Series Meters User Manual for specific instructions. Product Data Sheet

Open the catalog to page 1
Recordall Turbo Series Meters 6" and 20" - 2

Recordall® Turbo Series Meters, Models 6600 (16") & 10000 (20") SPECIFICATIONS Turbo Series Model Raised-Face Round Raised-Face Round Meter Flanges Typical Operating Range (100% ± 1.5%) Typical Low Flow (95% minimum) Maximum Continuous Flow Maximum Intermittent Flow Pressure Loss at Maximum Continuous Flow Maximum Operating Pressure Maximum Operating Temperature MATERIALS Meter Housing Turbo Head Nose Cone & Straightening Vanes Rotor Rotor Radial Bearings Rotor Thruster Bearing Rotor Bearing Pivots Calibration Mechanism Magnet Register Housing & Cover Trim Blue epoxy-coated cast iron Cast...

Open the catalog to page 2
Recordall Turbo Series Meters 6" and 20" - 3

Product Data Sheet PHYSICAL DIMENSIONS Turbo Series Model Meter & Pipe Size Net Weight Shipping Weight Number of Bolts Length (A) Width (B ) Height (C) Bolt Circle Centerline (E) PRESSURE LOSS CHART Rate of flow in gallons per minute (gpm)

Open the catalog to page 3
Recordall Turbo Series Meters 6" and 20" - 4

ACCURACY CHARTS Rate of flow in gallons per minute (gpm) Over Register Under Register Over Register Under Register Recordall is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved. The Americas | Badger Meter | 4545 West Brown Deer Rd | PO...

Open the catalog to page 4

All Badger Meter catalogs and technical brochures

  1. RVL Series

    8 Pages

  2. Model CB-30

    2 Pages

  3. 4000 series

    2 Pages

  4. RTR

    2 Pages

  5. ADE®

    2 Pages

  6. HR-E® LCD

    2 Pages

  7. HR-E

    2 Pages

  8. 735 series

    2 Pages

  9. M5000

    44 Pages

  10. M4000

    36 Pages

  11. M3000

    40 Pages

  12. M2000

    60 Pages