Recordall Turbo Series Meters 1-1/2" through 12
12Pages

{{requestButtons}}

Catalog excerpts

Recordall Turbo Series Meters 1-1/2" through 12 - 1

Recordall® Turbo Series Meters Models 160 (1-1/2"), 200 (2"), 450 (3"), 1000 (4"), 2000 (6"), 3500 (8"), 5500 (10"), & 6200 (12"); NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Recordall Turbo Series meters meet or exceed the most recent revision of AWWA Standard C701 Class II Standards and are available in a lead-free bronze alloy for sizes 1-1/2" through 10" and cast iron for 12" meters. Turbo Series meters comply with the lead-free provisions of the Safe Drinking Water Act. Sizes 1-1/2" through 10" meters are also certified to NSF/ANSI Standards 61 and 372 (Trade Designation: Turbo Series LL-NS) and carry the NSF-61 mark on the housing. All components of the lead-free alloy meter (housing, measuring element, seals and so on) comprise the certified system. Models 160 through 6200 are designed for 1-1/2" through 12" applications. These meters feature: • Direct coupled turbine based on an exclusive “floating rotor” design that reduces bearing friction—and associated wear and tear. Low pressure loss for improved system efficiency. Exceptional registration accuracy across low flow rate, normal operating flow rate and maximum continuous operation flow. Permanently sealed, tamper-resistant register or encoder. Integral strainer option for sizes 1-1/2" through 4" help protect your system from damaging debris and related downtime. Meters and encoders are compatible with Badger Meter AMR/AMI meter reading systems and other approved reading technologies. Applications: Recordall Turbo Series meters are designed for cold water, commercial and industrial applications where flows are consistent medium to high flows. Applications include hotels, apartment buildings, irrigations centers and manufacturing and processing plants. Turbo Series meters help reduce day-today maintenance costs while delivering accurate and efficient performance. Operation & Performance: Direct magnetic drive is achieved when the magnet carrier is driven by a gear train coupled to the rotor. The gear train consists of two sets of gears connected by a vertical transmission shaft. One gear set is at the magnet carrier, the other is a worm gear set at the rotor shaft. When water flows into the Turbo Series meter measuring element, it contacts the multi-vaned rotor. The resulting rotor rotation is then transmitted by magnetic coupling to a sealed register or encoder. The direct magnetic drive is built to provides a reliable meter-to-registration coupling. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX® tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. Construction: The Recordall Turbo Series meter is constructed in compliance with ANSI and AWWA C701 standards. It consists of the following basic components: meter housing, interchangeable, unitized measuring element and permanently sealed direct reading registers or encoders. The measuring element consists of the transmission coupling, rotor, inlet and outlet straightening vanes with nose cones, and calibration ring assembly. The unique inlet and outlet straightening vanes minimize swirl from piping arrangements upstream as well as downstream. A strainer is recommended to help ensure optimal flow conditioning and protection for the measuring element. An integral strainer is available as an option for 1-1/2" through 4" meter sizes. The stainless steel strainer is built into the inlet end and includes a removable cover plate to permit easy access for routine cleaning. External strainers are available in sizes 2" through 12". To simplify maintenance, the registers or encoders and measuring elements can be removed without removing the meter housing. Interchangeability of certain parts between meters also minimizes spare parts inventory investment. Meter Installation: The meter is designed for installations where flow is in one direction only. Companion flanges for installation of meters on various pipe types and sizes are available in cast iron or NL bronze as an option. See the Recordall Turbo Series Meters User Manual for specific instructions. Product Data Sheet

Open the catalog to page 1
Recordall Turbo Series Meters 1-1/2" through 12 - 2

Recordall® Turbo Series Meters SPECIFICATIONS Turbo Series Model Meter Flanges AWWA 125 Pound Class Round AWWA 125 lb class Typical 4…200 gpm 4…310 gpm 5…550 gpm 10…1250 gpm 20…2500 gpm 30…4500 gpm 50…7000 gpm 90…8800 gpm Operating Range (0.9…45.4 m3/h) (0.9…70.4 m3/h) (1.1…124.9 m3/h) (2.3…284 m3/hr) (4.5…568 m3/h) (6.8…1022 m3/h) (11.4…1590 m3/h) (20.5…1998 m3/h) (100% ± 1.5%) Typical Low Flow 2.5 gpm (0.6 m3/h) 2.5 gpm (0.6 m3/h) 4 gpm (0.9 m3/h) 6 gpm (1.4 m3/h) 12 gpm (2.7 m3/h) 20 gpm (4.5 m3/h) 30 gpm (6.8 m3/h) 65 gpm (95% min.) (14.8 m3/h) Max. Continuous 160 gpm 200 gpm 450 gpm...

Open the catalog to page 2
Recordall Turbo Series Meters 1-1/2" through 12 - 3

Product Data Sheet REGISTERS / ENCODERS Standard—Sweep-Hand Registration The standard register is a straight-reading, permanently sealed magnetic drive register. Dirt, moisture, tampering and lens fogging problems are eliminated. The register has a six-odometer wheel totalization display, 360° test circle with center sweep hand, and flow finder to detect leaks. Register gearing is made of self-lubricating engineered polymer, which minimizes friction and provides long life. The multi-position register simplifies meter installation and reading. The high-flow register capacity for the 1-1/2",...

Open the catalog to page 3
Recordall Turbo Series Meters 1-1/2" through 12 - 4

Recordall® Turbo Series Meters PHYSICAL DIMENSIONS OF METERS WITHOUT STRAINER NPT Test Port & Test Plug (1-1/2 . . . 8”) Figure 1: Sample Illustration from 8" Model 3500 Turbo Series Model Meter Flanges Meter & Pipe Size Shipping Weight NPT Test Port & Test Plug (optional)

Open the catalog to page 4

All Badger Meter catalogs and technical brochures

  1. RVL Series

    8 Pages

  2. Model CB-30

    2 Pages

  3. 4000 series

    2 Pages

  4. RTR

    2 Pages

  5. ADE®

    2 Pages

  6. HR-E® LCD

    2 Pages

  7. HR-E

    2 Pages

  8. 735 series

    2 Pages

  9. M5000

    44 Pages

  10. M4000

    36 Pages

  11. M3000

    40 Pages

  12. M2000

    60 Pages