Catalog excerpts
Recordall® Cold Water Bronze Disc Meter Size 5/8, 5/8 x 3/4" (DN 15mm) Model LP NSF/ANSI Standard 61 Certified, Annex G DESCRIPTION Badger Meter offers the Recordall Disc meter in a bronze lead-free alloy. The Lead-Free Alloy (Trade Designation: MLP-LL) meter has been certified to comply with NSF/ANSI Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Lead-Free Alloy meter, i.e., disc, chamber, housing, seals, etc. comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. OPERATING PERFORMANCE: The Badger Meter Recordall Disc meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated by AWWA Standard C700. CONSTRUCTION: Badger Meter Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber, and permanently sealed register. The water meter is available in a Bronze Lead-Free Alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and liner/strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like-sized meters also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. MAGNETIC DRIVE: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight-reading odometer-type totalization display, 360° test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self-lubricating engineered polymer gears to minimize friction and provides long life. Permanently sealed; dirt, moisture, tampering and lens fogging problems are eliminated. Multi-position register simplifies meter installation and reading. Automatic meter reading systems are available for all Recordall Disc meters. All reading options are removable from the meter without disrupting water service. TAMPER-PROOF FEATURES: Customer removal of the register to obtain free water can be prevented when the optional tamper detection seal wire screw or TORX® tamper resistant seal screw is added to the meter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Meter Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. As an alternative to repair by the utility, Badger Meter offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. RD-T-MLP-AWWA (11-11) Model LP SPECIFICATIONS Typical Operating 1/2 - 20 GPM (.057 to 4.5 m3/hr) (100% ± 1.5%) Low Flow 1/4 GPM (.028 m3/hr) (Min. 95%) Maximum 10 GPM (2.3 m3/hr) Continuous Operation Pressure Loss 5/8": 2 PSI at 10 GPM (.14 bar at .2.3 m3/hr) at Maximum 5/8"x3/4":1.5 PSI at 10 GPM (.10 bar at 2.3 m3/hr) Continuous Operation Maximum Operating 80°F (26°C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement Register Type Straight reading, permanently sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Register Capacity 10,000,000 Gallons, 1,000,000 Cubic Feet, 100,000 m3. 6 odometer wheels. Meter Connections Available in bronze and Engineered Polymer to fit 5/8" or 3/4" (DN 15mm) spud thread bore diameter sizes. See table below. METER SPUD AND CONNECTION SIZES Size Designation x "L" Laying Length "B" Bore Dia. Coupling Nut and Spud Thread Tailpiece Pipe Thread (NPT) 5/8" x 5/8" x 3/4" x 7-1/2" 5/8" 3/4" (5/8") 1/2" 7-1/2" 5/8", 3/4" 1" (3/4") 3/4" MATERIALS Meter Housing Bronze Lead-Free Alloy Housing Bottom Plates Bronze Lead-Free Alloy, Cast Iron, Engineered Polymer Measuring Chamber Engineered Polymer Disc Engineered Polymer Trim Stainless Steel, Bronze Liner/Strainer Polymer Engineered Disc Spindle Engineered Polymer Magnet Ceramic Magnet Spindle Engineered Polymer Register Lid and Shroud Engineered Polymer, Bronze Technical Brief
Open the catalog to page 1PRESSURE LOSS CHARTS Rate of Flow, in Gallons per Minute 3/4" 5/8" A B B C APPROX. METER METER LAYING HEIGHT HEIGHT CENTERLINE SHIPPING SIZE MODEL LENGTH REG./RTR® ADE® BASE WIDTH WEIGHT 5/8" , 5/8" X 3/4" LP 71/2" 3.70"/4.12" 4.62" 1.26" 3.75" 3 lbs. (15mm) (190mm) ACCURACY CHART Rate of Flow, in Gallons per Minute Register with with Register BronzeLid Bronze Lid and Shroud and Shroud Register with Register with Plastic Lid Plastic Lid and Shroud and Shroud 9 0 Model 9 1 LP Recordall ® 8 2 8 ® 3 4 Gallons 0 .9 ® .2 GALLON CU. FT. CU. METER LP 10 1 .1 0 .1 Model LP ® Recordall .8 .2 Badger...
Open the catalog to page 2All Badger Meter catalogs and technical brochures
-
HR-E® LCD Encoder
2 Pages
-
Recordall® Disc Meters
8 Pages
-
RVL Series
8 Pages
-
VN2000 Flow Meters
8 Pages
-
Field Flow Calibrator
4 Pages
-
Body Leakage Tester
2 Pages
-
Measurable Results
12 Pages
-
Blancett Overview
8 Pages
-
Oil and Gas Market
8 Pages
-
Automotive Products
12 Pages
-
Model CB-30
2 Pages
-
4000 series
2 Pages
-
Test and Measurement
20 Pages
-
Cox Exact Dual Rotor
8 Pages
-
RTR
2 Pages
-
ADE®
2 Pages
-
HR-E® LCD
2 Pages
-
HR-E
2 Pages
-
SRI990 Analog Positioner
2 Pages
-
735 series
2 Pages
-
GALAXY® Water Products
2 Pages
-
Model M2000 Detector
2 Pages
-
Model M2000 Amplifier
2 Pages
-
Oval Gear Meter
1 Pages
-
M5000
44 Pages
-
M4000
36 Pages
-
M3000
40 Pages
-
M2000
60 Pages