E-Series 5/8 through 1 inch Standard
4Pages

{{requestButtons}}

Catalog excerpts

E-Series 5/8 through 1 inch Standard - 1

E-Series® Meter Cold Water Stainless Steel Ultrasonic Meter Model E-25, E-35 and E-55 - NSF/ANSI Standard 61 Certified, Annex G The electronic Badger Meter E-Series® meter utilizes ultrasonic and solid-state technology in a compact, totally encapsulated, weatherproof, and UV-resistant housing for residential and commercial applications. Electronic metering provides information and data not typically available through traditional, mechanical meters and registers, such as rate of flow and reverse flow indication, and eliminates measurement errors due to sand, suspended particles and pressure fluctuations. Offered in four sizes and lay lengths, the E-Series meter features: • Minimum extended low-flow rate lower than typical positive displacement meters. • Simplified one-piece electronic meter and register that are integral to the meter body and virtually maintenance free. • Sealed, non-removable, tamper-protected meter and register. • Easy-to-read 9-digit LCD display – presents consumption, rate of flow, reverse-flow indication, and alarms. • Digital or industry standard encoder protocol. The E-Series Meter is available with a wired lead, 308 in-line connector or fully prewired to ORION® and GALAXY® AMR/AMI endpoints. It is also offered with the Itron® in-line connector, in-line connector with pit endpoint, or prewired to an Itron remote endpoint. Applications Use the E-Series meter for measuring potable cold water in residential, commercial and industrial services. The meter is also ideal for non-potable, reclaimed irrigation water applications or less than optimum water conditions where small particles exist. The E-Series meter complies with applicable portions of ANSI/ AWWA Standard C700 and NSF/ANSI Standard 61, Annex G. There is currently no AWWA standard that specifically addresses ultrasonic meters for residential applications. Operation & Performance As water flows into the measuring tube, ultrasonic signals are sent consecutively in forward and reverse directions of flow. Velocity is then determined by measuring the time difference between the measurement in the forward and reverse directions. Total volume is calculated from the measured flow velocity using water temperature and pipe diameter. The LCD display shows total volume and alarm conditions and can toggle to display rate of flow. ESM-T-01-EN (2-12) In the normal temperature range, the E-Series “new meter” consumption measurement is accurate to: • ±1.5% over the normal flow range • ±3.0% from the extended low flow range to the minimum flow value Construction E-Series meters feature a stainless steel, lead-free meter housing, an engineered plastic and stainless steel metering insert, a metercontrol circuit board with associated wiring, LCD, and battery. Wetted elements are limited to the pressure vessel, plastic/ stainless steel metering insert and the transducers. The electronic components are housed and fully potted within a molded, engineered plastic enclosure, which is permanently attached to the meter housing. The transducers extend through the stainless steel housing and are sealed by O-rings. The metering insert holds the stainless steel ultrasonic reflectors in the center of the flow area, enabling turbulence-free water flow through the tube and around the ultrasonic signal reflectors. The metering insert’s patented design virtually eliminates chemical buildup on the reflectors, ensuring long-term metering accuracy. Meter Installation The meter is completely submersible and can be installed using horizontal or vertical piping, with flow in the up direction. The meter will not measure flow when an “empty pipe” condition is experienced. An empty pipe is defined as a condition when the flow sensors are not fully submerged. Technical Brief

Open the catalog to page 1
E-Series 5/8 through 1 inch Standard - 2

Specifications E-Series Meter Model E-25 Model E-25 Model E-35 Model E-55 Size 5/8" (DN 15 mm) 5/8" x 3/4" (DN 15 mm) 3/4" (DN 20 mm) 1" (DN 25 mm) Operating Range 0.1 GPM - 25 GPM 0.1 GPM - 25 GPM 0.1 GPM - 32 GPM 0.4 GPM - 55 GPM Extended Low-Flow Rate 0.05 GPM 0.05 GPM 0.05 GPM 0.25 GPM Maximum Continuous Operation 25 GPM 25 GPM 32 GPM 55 GPM Pressure Loss 4.3 PSI at 15 GPM 3 PSI at 15 GPM 1.8 PSI at 15 GPM 1.8 PSI at 25 GPM Reverse Flow - Maximum Rate 4.0 GPM 4.0 GPM 4.0 GPM 9.0 GPM Operating Performance In the normal temperature range, new meter consumption measurement is accurate to:...

Open the catalog to page 2
E-Series 5/8 through 1 inch Standard - 3

Physical Dimensions E-Series Meter Model E-25 Model E-25 Model E-35 Model E-55 Size Designation X Lay Length 5/8" x 7-1/2" 5/8” x 3/4” x 7-1/2” 3/4" x 7-1/2" or 3/4" x 9" 1" x 10-3/4" Weight (without AMR) 2.2 lbs. 2.1 lbs 3/4 " x 7-1/2 ": 2.1 lbs 3/4" x 9": 2.4 lbs. 3.1 lbs. Length (A) 7.5" 7.5” 7.5” or 8.98” 10.745" Height (B ) 2.404" 2.404” 2.404” 2.529" Height (C) 3.014" 3.014” 3.094” 3.359" Width (D) 3.898" 3.898” 3.898” 3.898” Bore Size 5/8" 3/4" 3/4" 1" Coupling Nut & Spud Thread 3/4" x 14 NPSM 1" x 11-1/2 NPSM 1" x 11-1/2 NPSM 1-1/4" x 11-1/2 NPSM Tailpiece Pipe Thread (NPT) 1/2"...

Open the catalog to page 3
E-Series 5/8 through 1 inch Standard - 4

E-Series, GALAXY and ORION are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective owners. © 2012 Badger Meter, Inc. All rights reserved. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. Badger Meter | P.O. Box 245036, Milwaukee, Wisconsin 53224-9536 800-876-3837 | infocentral@badgermeter.com | www.badgermeter.com 4 | Technical Brief

Open the catalog to page 4

All Badger Meter catalogs and technical brochures

  1. RVL Series

    8 Pages

  2. Model CB-30

    2 Pages

  3. 4000 series

    2 Pages

  4. RTR

    2 Pages

  5. ADE®

    2 Pages

  6. HR-E® LCD

    2 Pages

  7. HR-E

    2 Pages

  8. 735 series

    2 Pages

  9. M5000

    44 Pages

  10. M4000

    36 Pages

  11. M3000

    40 Pages

  12. M2000

    60 Pages