Catalog excerpts
Pinch Valves . . . . . . . . . . . . . . . . . . . . .
Open the catalog to page 1Special Purpose Index SOLENOID VALVES SOLENOID VALVES | Special PurposeProportional Proportional | GEM-SOL | Isolated Proportional 2 Way NC GEM-CPR | Isolated Proportional 2 Way NC Technical Data Typical performance graph Media : Water Ap : 0.9 [bar] Temp : 200C Dimensions How to Order PORT Example : GEM-CPR-4011E1-1 Isolated proportional valve, 1/2" BSP, 2W NC, Vacuum, EPDM seals, plastic manual override, with 0-5V control signal. (1) Maximum inlet pressure : 1 bar *Please specify the working pressure range when placing an order SOLENOID VALVES * To order valves manufactured according to...
Open the catalog to page 2Special Purpose Index SOLENOID VALVES | Special Purpose Proportional Proportional | G65 | 2 Way NC G65-PR | Proportional 2 Way NC Dimensions SOLENOID VALVES Technical Data Function Guidelines for selection : 1. The pressure drop (AP) on the valve should be 30-50% or higher, of the total pressure drop in the system. 2. Special consideration should be taken in choosing the right Kv of the valve as this factor determines the flow and pressure drop of the valve. 3. To achieve better regulation performance when working without a control unit, the maximum pressure should be 1.2 times the working...
Open the catalog to page 3Special Purpose Index SOLENOID VALVES SOLENOID VALVES | Special PurposeProportional Proportional | G80 | 2 Way NC G80-PR | Proportional 2 Way NC Dimensions Port thread SOLENOID VALVES Technical Data Guidelines for selection 1. The pressure drop (AP) on the valve should be 30-50% or higher, of the total pressure drop in the system. 2. Special consideration should be taken in choosing the right Kv of the valve as this factor determines the flow and pressure drop of the valve. 3. To achieve better regulation performance when working without a control unit, the maximum pressure should be 1.2...
Open the catalog to page 4Special Purpose Index SOLENOID VALVES SOLENOID VALVES | Special PurposeProportional Proportional | GEM-SOL | Proportional 2 Way NC GEM-PR | Proportional 2 Way NC Dimensions SOLENOID VALVES Brass / Stainless Steel Technical Data Function Guidelines for selection 1. The pressure drop (AP) on the valve should be 30-50% or higher, of the total pressure drop in the system. 2. Special consideration should be taken in choosing the right Kv of the valve as this factor determines the flow and pressure drop of the valve. 3. To achieve better regulation performance when working without a control unit,...
Open the catalog to page 5Special Purpose Index SOLENOID VALVES SOLENOID VALVES | Special PurposeHigh pressure High pressure | GEM-SOL | 1/4" - 1" 2 Way NC, NO GEM-HP | 1/4" - 1" 2 Way NC, NO Dimensions Flow direction Brass | 1/2" Stainless Steel | 1/2" Size SOLENOID VALVES Technical Data Pressure (bar) & Flow table NC * When ordering without coil, please define what current and pressure rating is needed (DC, AC) • Latch valves are available upon request. Pressure (bar) & Flow table NO VOLTAGE POWER CONNECTOR W/out coil 6 12 24 48 flying leads coil Voltage & Power Consumption with 1/2" Hub 5 surge protec- 6 tion...
Open the catalog to page 6Special Purpose Index SOLENOID VALVES | Special Purpose Isolated Isolated | G80 | Chem-Sol 1/8" 2 Way NC, NO G80-CS | Chem-Sol 1/8" 2 Way NC, NO Dimensions NC NO Technical Data Voltage & Power Consumption , * When ordering without coil, please define whatHOW tO Order current and pressure rating is needed (DC, AC) Function • Available options * To order valves manufactured according to your specific requirements, please contact our technical sales department. BACCARA VALVES CATALOG 77 Pneumatics, Automation & Control Solut
Open the catalog to page 7Special Purpose Index SOLENOID VALVES | Special Purpose Isolated Isolated | GEM-SOL | Chem-Sol 1/4" 2 Way NC, NO GEM-C | Chem-Sol 1/4" 2 Way NC, NO Dimensions SOLENOID VALVES Technical Data Coil & power rating (1) Higher input pressure of up to 1atm can be achieved with minimal pressure drop on the valve of 0.3atm * ADC valves are only suitable for use with AC8W or DC10W coils. Voltage & Power Consumption NC & NO valves Example : GEM-C-12012V1-321 GEM-SOL Chem-Sol, PPA, 1/4"BSP, 2W NC, Pressure, FPM (Viton®), plastic manual override, 24V AC 8W 60 Hz with connector. connector with moulded 7...
Open the catalog to page 8Special Purpose Index SOLENOID VALVES | Special Purpose Isolated Isolated | GEM-SOL | Chem-Sol 1/2" 2 Way NC GEM-C | Chem-Sol 1/2" 2 Way NC Dimensions with Manual Override standard : without thread optional : M4x0.7 Deep 10 inserts TYPx2 SOLENOID VALVES Technical Data Pressure (bar) table NC How to Order With Manual Override * When ordering without coil, please define what current and pressure rating is needed (DC, AC) • Supplied with mounting threads on request, please specify. Vacuum (bar) table NC Coil Voltage & Power Consumption AC (W) • Available options • Vacuum • Pressure Example :...
Open the catalog to page 9SOLENOID VALVES Special Purpose Index SOLENOID VALVES | Special Purpose Isolated Isolated | GEM-SOL | Chem-Sol 3/4" 2 Way NC GEM-C | Chem-Sol 3/4" 2 Way NC Dimensions SOLENOID VALVES Technical Data Pressure (bar) table NC , * When ordering without coil, please define what HOW tO Order current and pressure rating is needed (DC, AC) * Coil : Suitable for all available wattage, see How to Order table * Coil : Suitable for all available wattage, see How to Order table Voltage & Power Consumption • Available options Example : GEM-C-5011V-3G1 GEM-SOL Chem-Sol, 3/4'BSP, 2W NC for vacuum, FPM...
Open the catalog to page 10Special Purpose Index SOLENOID VALVES SOLENOID VALVES | Special PurposePinch Valves Pinch Valves | GEM-SOL | 2 Way NC GEM-P | Pinch valve 2 Way NC Dimensions SOLENOID VALVES Technical Data Voltage & Power Consumption • Available options flying leads coil with 1/2" Hub 5 surge protec- 6 tion with LED connector with moulded 7 cable other 9 Example : GEM-P-11-331 GEM-SOL pinch valve for 06x4 silicone tube, 2W NC 24V DC 10W with connector [gem-p- 1 1 - 3 3 1 (1) For specifying Latch type coil, please refer to GEM-A3P valve - How to Order table. GEM - P- 1D * To order valves manufactured...
Open the catalog to page 11All BACCARA AUTOMATION catalogs and technical brochures
-
Instrumentation & Control
12 Pages
-
Process Valves
11 Pages