PDTD90-2

PDTD90-2

PDTD90-2

Product catalog summary
Overview
The PDTD90-2 system by b2 electronic GmbH is designed for diagnosing medium voltage cables, rotating machinery, and transformers using Partial Discharge (PD) and Tan Delta (TD) diagnostics. It is compact, portable, and integrates both PD and TD measurement capabilities.

Partial Discharge Diagnostics (PD)
PD diagnostics help in early detection of vulnerabilities in medium and high voltage cables by precisely locating PD faults, often caused by mechanical damage or faulty installation. The system offers features like PD mapping, phase-resolved PD display, and high noise suppression.

Tan Delta Diagnostics (TD)
TD diagnostics assess the overall dielectric condition of cables, particularly useful for detecting water tree damage in XLPE/PE/XLPE cables, which cannot be identified by PD measurement alone.

Features
  • Simultaneous PD and TD measurement
  • b2 Suite® software for diagnostics and data management
  • Manual and automatic diagnostic modes
  • High accuracy and extensive reporting capabilities
  • Compliance with IEC 60270 and IEEE400.2-2013 standards

Technical Specifications
  • Input supply voltage: 110/240 VAC, 50/60 Hz
  • Operating voltage: sinusoidal 64 kV rms, 90 kV peak
  • Frequency: 0.01-0.1 Hz
  • PD localization accuracy: 1%
  • PD resolution: 0.1 pC, 0.1 m
  • Tan Delta measurement accuracy: ± 1 x 10-4

Software and Accessories
The b2 Suite® software facilitates guided diagnostics, data analysis, and reporting. The system includes essential accessories like HV cables and transport boxes, but requires a separate VLF generator.

Conclusion
The PDTD90-2 system provides a comprehensive solution for PD and TD diagnostics, offering high precision and ease of use for field applications.
See more

Catalog excerpts

PDTD90-2-1

PARTIAL DISCHARGE AND TAN DELTA DIAGNOSTICS SYSTEM simultaneous measurement of PD and TD Software incl. Database The b2 electronic GmbH PDTD90-2 Partial Discharge (PD) and Tan Delta (TD) diagnotics system for diagnosis of medium voltage cables, rotating machinery and transformers. PARTIAL DISCHARGE DIAGNOSTICS (PD) The Partial Discharge diagnostics on medium and high voltage cable offers the possibility of early detection of vulnerabilities through a precise localization of PD faults in cables and their connections (joints and terminations), often caused by mechanical damage or a faulty installation process. TAN DELTA DIAGNOSTICS (TD) The Tan Delta diagnostics (TD) allows a statement about the overall dielectric condition of cables. A deterioration or damage by so-called water trees in XLPE/PE/XLPE cables can be easily detected. Water Trees cannot be identified or measured with a sole partial discharge measurement. Compact, light and portable devices Simultaneous Partial Discharge and Tan Delta measurement b2 Suite® - comprehensive diagnostic software and database Display of cable route on OpenStreetMap® Very simple and clear measurement process Manual and automatic diagnostic mode Exact PD localization (PD mapping) Phase-resolved PD display (PD Pattern) PD Magnitude PD inception and extinction voltage PD rate High noise suppression by filtering Very high accuracy for Tan Delta measurement Extensive reporting Test setup according to IEC 60270 and calibration Monitored Withstand Test (MWT) according IEEE400.2-2013 PD and TD measurement unit in one device PD and TD me

 Open the catalog to page 1
PDTD90-2-2

PDTD90-2 PARTIAL DISCHARGE & TAN DELTA DIAGNOSTICS SYSTEM PDTD90-2 DIAGNOSTICS WITH VLF The diagnostic system PDTD90-2 (in combination with a VLF generator1) enables comprehensive diagnosis with sinusoidal output voltage with constant frequency, which is a prerequisite for the comparison of PD and TD measurement results of cables with different lengths. Load-dependent and therefore constantly changing measurement frequencies offer no basis for this. The sine wave output voltage is the only described VLF voltage form in IEEE400.2-2013 for partial discharge and tan delta measurements and provides...

 Open the catalog to page 2
PDTD90-2-3

FEATURES • Automatic or manual modes for testing and PD diagnostics • Precise location of PD events on cable insulation, terminations and joints • Presentation of PD events over total cable length • Phase-resolved presentation (pattern) of PD • PD inceptions- and extinction voltage • Guided Diagnostics Process - leads the operator through diagnostics step by step • Automatic & manual gain and trigger setting • Sets or recommends measuring parameters • Recommended by Standards (CENELEC &IEEE), with guidance for interpretation in literature • Analog and digital frequency filters • Direct Mapping...

 Open the catalog to page 3
PDTD90-2-4

www.b2hv.com I [email protected] PARTIAL DISCHARGE DIAGNOSTICS SYSTEM (PD) 1 Calibration Certificate for variable frequencies optional, 2b2 Suite V2 optional, 3 Please note: A VLF (0.1 high voltage generator (required) is not included in the scope of delivery.

 Open the catalog to page 4

All B2 electronics GmbH catalogs and technical brochures

  1. PDTD68

    3  Pages

  2. HVA68TD EN

    4  Pages

  3. PD30-E

    4  Pages

  4. PDTD60-2

    4  Pages

  5. PDTD120-2

    4  Pages

  6. BA100

    2  Pages

  7. TD90-MC

    2  Pages

  8. TD60-MC

    2  Pages

  9. TD120-MC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.