HVA90 datasheet

HVA90 datasheet

HVA90 datasheet

Product catalog summary
Overview: The HVA90 VLF High Voltage Test Set is designed for testing medium voltage cables up to 69 kV, offering a compact design with a high power-to-weight ratio. It supports VLF, DC, and sheath testing, with additional capabilities for sheath fault location.
Key Features:
  • Pure sinusoidal output voltage, independent of load.
  • Real-time oscilloscope display of output voltage.
  • Programmable test sequences with software tool.
  • USB report downloads for easy data management.
  • Continuous operation without thermal limitations.
Performance and Safety:
  • Two independent discharge devices for safety.
  • Integrated 12 kV transient protection system.
  • Robust HV connectors for flexible test lead usage.
Technical Specifications:
  • Output voltage: Max 90 kVpeak, 64 kVrms.
  • Output load: 1.0 μF at 0.1 Hz at 64 kVrms.
  • Weight: 127 kg (280 lbs).
  • AC frequency range: 0.01 Hz to 0.1 Hz.
  • Operating temperature: -10 to +50 °C.
Testing Capabilities:
  • VLF withstand test, DC test, sheath test, and sheath fault location.
  • Manual and automatic test modes with user-definable sequences.
  • Compliance with IEEE 400.2 and IEC standards.
Data Management:
  • USB and RS232 data transfer options.
  • Built-in memory for up to 50 reports and 40 test sequences.
  • PC software included for enhanced control and reporting.
Included Accessories:
  • HV test lead, earth lead, power cord, manuals, and data storage device.
Optional Accessories:
  • Discharge stick, transport case, and diagnostic systems for Tan Delta and Partial Discharge.
See more

Catalog excerpts

HVA90 datasheet-1

HVA90 VLF high voltage test set Datasheet The HVA90 is a perfectly suitable test set to determine the condition of medium voltage cables with a voltage rating up to 69 kV (acc. to IEEE 400.2-2013). Its compact design and unmatchable high voltage output power to weight ratio is second to none on the market and makes it an excellent option for cable testing up to 64 kVrms and 90 kVpeak (sine wave operation). Beside the VLF and DC testing, the HVA90 performs also sheath testing with sheath fault location mode (here, however, additional fault probe is needed). Performance: Outstanding features considering size and weight vs. output load. Duty cycle: No thermal limitation! You can use the test set continuously. Safety first: Two independent discharge devices (electronic and mechanical discharging) and an integrated 12 kV transient protection system (at 50/60 Hz). Connectivity: On-site, no external PC is needed. All results can be later downoaded via USB for further l investigation and easy reporting via the b2 ControlCenter. Solid HV connectors: Robust HV connectors allow the use of various HV test lead lengths, quick exchange of a replacement cable, or a simpler upgrade path for connection of diagnostics systems. Output voltage Output load DHV1445 Rev00 – © b2 electronics GmbH – Subject to change without notice. YOUR BENEFITS TD AND PD DAGNOSTICS HVA90 can be extended to a complete cable diagnostic system at any time. DRY SYSTEM HVA test sets are constructed with nonarcing contacts and no need to change oil. This eliminates routine servicing and makes the test sets almost maintenance-free. UNLIMITED OPERATING TIME HVA generators are designed for continuous operation without any thermal limitations. COMPACT AND PORTABLE Our HVA series have been designed for maximum portability and on-site use. It makes them widely applicable for in-field use. • Pure sinusoidal output voltage (load-independent) • Sheath fault pinpointing in combination with sheath fault locator (not included) • Easily exchangeable HV test lead • Breakdown voltage and load detection • Real time oscilloscope of the output voltage on the HVA display • Programmable test sequences with a tailor-made software tool • Report downloads from the device via USB flash drive

 Open the catalog to page 1
HVA90 datasheet-2

HVA90 VLF high voltage test set Datasheet TECHNICAL DATA Output characteristics VLF sine wave DC VLF square wave Sheath test Voltage setting resolution AC frequency range Frequency setting resolution AC DC Sheath test trip current Sheath fault location Output voltage Output current Duty cycle 0 ... 64 kVrms / 0 ... 90 kVpeak -90 kV ... 90 kV 0 ... 90 kV 0 ... 10 kV (negative polarity) 0.1 kV 0.01 Hz ... 0.1 Hz 0.01 Hz 41 mArms max. 57 mA max. 0.1 ... 5 mA 40 mA max. Continuous, no thermal limitation of operating time Load diagram for sine wave DHV1445 Rev00 – © b2 electronics GmbH – Subject to...

 Open the catalog to page 2
HVA90 datasheet-3

HVA90 VLF high voltage test set Datasheet High voltage tests (continued) Manual mode Automatic test sequences (user definable) Burn on arc Trip out on arc VLF withstand testing according to IEEE 400.2 and the test standards DIN VDE 0276-620 (CENELEC HD 620 S2), DIN VDE 0276-621 (CENELEC HD 621 S1) AC and sheath testing according to IEC 60502-2 / IEC 60229 Test modes Arc management modes DHV1445 Rev00 – © b2 electronics GmbH – Subject to change without notice. AC TrueRMS Maximum display value Resolution Accuracy Output voltage measurement range DC Maximum display value Resolution Accuracy AC TrueRMS...

 Open the catalog to page 3
HVA90 datasheet-4

HVA90 VLF high voltage test set Datasheet Further characteristics Data transfer Report management PC software Dimensions L x W x H Weight USB type A RS232 Built-in memory: up to 50 reports, 40 test sequences USB flash drive: dependent on storage capacity b2 ControlCenter (included) HVA ControlCenter (included) 545 x 445 x 610 mm 21.45 x 17.51 x 24 in 127 kg / 280 lbs SCOPE OF SUPPLY Art. No. HVA90 VLF High Voltage Test Set Included accessories HVA94 HV test lead 100 kV PD 7 m MC14 Earth lead 4 m 6 mm2 transparent M6/clamp Power chord country specific - Unit side C19 HVA language specific manual...

 Open the catalog to page 4

All B2 electronics GmbH catalogs and technical brochures

  1. PDTD68

    3  Pages

  2. HVA68TD EN

    4  Pages

  3. PD30-E

    4  Pages

  4. PDTD60-2

    4  Pages

  5. PDTD90-2

    4  Pages

  6. PDTD120-2

    4  Pages

  7. BA100

    2  Pages

  8. TD90-MC

    2  Pages

  9. TD60-MC

    2  Pages

  10. TD120-MC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.