1. Catalogs
  2. b2 electronics GmbH
  3. HVA45 & HVA45TD datasheet

HVA45 & HVA45TD datasheet

HVA45 & HVA45TD datasheet

HVA45 & HVA45TD datasheet

Product catalog summary
Overview: The HVA45 and HVA45TD are compact and portable Very Low Frequency (VLF) high voltage test sets designed for assessing the condition of medium voltage cables. They offer VLF and DC testing, as well as sheath testing with fault location capabilities. The HVA45TD model includes an integrated Tan Delta diagnostics unit, enhancing its diagnostic capabilities.
Key Features:
  • Pure sinusoidal output voltage that is load-independent.
  • Bluetooth communication for safe data transfer.
  • Large 4.3-inch color display for easy operation.
  • Programmable test sequences with a dedicated software tool.
  • Data download via USB flash drive.
  • Optional +4 kV extension for increased output voltage.
Performance and Safety:
  • Continuous duty cycle with no thermal limitations.
  • Two independent discharge devices and a 12 kV transient protection system ensure safety.
  • IP67-rated watertight and rugged case for durability.
Technical Specifications:
  • Maximum output voltage: 45 kVpeak, 32.3 kVrms (49 kVpeak, 34.6 kVrms with +4 kV option).
  • Output load: 0.9 μF at 0.1 Hz at 32 kVrms (0.8 µF at 0.1 Hz at 34 kVrms with +4 kV option).
  • Weight: 39 kg (86 lbs).
  • AC frequency range: 0.01 Hz to 0.1 Hz.
  • Output current: AC 30 mArms max, DC 45 mA max.
Testing Capabilities:
  • VLF withstand test, VLF Tan Delta test (HVA45TD only), Monitored Withstand Test (HVA45TD only), DC test, Sheath test, and Sheath fault location.
  • Compliance with IEEE 400.2 and other international standards.
Metering and Accuracy:
  • Output voltage measurement with high accuracy and resolution.
  • Tan Delta measurement range and accuracy for HVA45TD.
  • Resistance and capacitance measurement capabilities.
Additional Features:
  • Manual and automatic test modes with user-definable sequences.
  • Arc management modes including burn on arc and trip out on arc.
  • Built-in memory for up to 50 reports and test sequences, with additional storage via USB.
Environmental and Operational Conditions:
  • Operating temperature range: -20 to +55 °C.
  • Storage temperature range: -25 to +70 °C.
  • Humidity: 5 to 85%, non-condensing.
Included Accessories: The datasheet lists various accessories included with the HVA45 and HVA45TD models, such as test leads, earth leads, power cords, manuals, Bluetooth USB adapter, and more.
See more

Catalog excerpts

HVA45 & HVA45TD datasheet-1

HVA45 & HVA45TD VLF high voltage test set Datasheet The HVA45 and HVA45TD are truly compact and portable VLF test sets that determine the condition of medium voltage cables. Both test sets perform VLF and DC testing, as well as sheath testing with sheath fault location possibilities. In order to meet international test guides (e.g. IEEE 400.2-2013) the HVA45TD combines the small and lightweight VLF test set with an integrated Tan Delta diagnostics unit. With the available +4 kV option you can extend the possible output voltage of this test set even further. Performance: Outstanding features considering size and weight vs. output load. Duty cycle: No thermal limitation! You can use the test set continuously. Safety first: Two independent discharge devices (electronic and mechanical discharging) and an integrated 12 kV transient protection system (at 50/60 Hz). Connectivity: On-site, no external PC is needed. All results can be later downoaded via USB or Bluetooth for l further investigation and easy reporting via the b2 ControlCenter. MWT: In addition, HVA45TD offers a Monitored Withstand Test, a combination of withstand testing and Tan Delta diagnostics in compliance with the guide IEEE 400.2-2013. with +4 kV option Output voltage Output load DHV1453 Rev00 – © b2 electronics GmbH – Subject to change without notice. YOUR BENEFITS SMALL AND LIGHTWEIGHT The HVA series offers the smallest and lightest VLF hipot test sets available. This makes them widely applicable for in-field use. DRY SYSTEM HVA test sets are constructed with nonarcing contacts and no need to change oil. This eliminates routine servicing and makes the test sets almost maintenance-free. UNLIMITED OPERATING TIME HVA generators are designed for continuous operation without any thermal limitations. IP67 A watertight and very rugged case with a protection class of IP67 makes additional transport boxes obsolete. • Pure sinusoidal output voltage (load-independent) • Sheath fault pinpointing in combination with sheath fault locator (not included) • Easily exchangeable HV test lead • Safe communication over Bluetooth • Large color display (4.3") • Programmable test sequences with a tailor-made software tool • Download reports from the device via USB flash d

 Open the catalog to page 1
HVA45 & HVA45TD datasheet-2

HVA45 & HVA45TD VLF high voltage test set Datasheet TECHNICAL DATA Output characteristics VLF sine wave DC VLF square wave Sheath test Voltage setting resolution AC frequency range Frequency setting resolution AC DC Sheath test trip current Sheath fault location Output voltage Output current Duty cycle 0 ... 32.3 kVrms / 0 ... 45 kVpeak 0 ... 34.6 kVrms / 0 ... 49 kVpeak -45 kV ... 45 kV 0 ... 45 kV 0 ... 15 kV (negative polarity) 0.1 kV 0.01 Hz ... 0.1 Hz 0.01 Hz 30 mArms max. 45 mA max. 0.1 ... 10 mA 25 mA max. Continuous, no thermal limitation of operating time Load diagram for sine wave 10.0...

 Open the catalog to page 2
HVA45 & HVA45TD datasheet-3

HVA45 & HVA45TD VLF high voltage test set Datasheet High voltage tests (continued) Manual mode Automatic test sequences (user definable) Burn on arc Trip out on arc VLF withstand testing according to IEEE 400.2 and the test standards DIN VDE 0276-620 (CENELEC HD 620 S2), DIN VDE 0276-621 (CENELEC HD 621 S1) AC and sheath testing according to IEC 60502-2 / IEC 60229 Test modes Arc management modes DHV1453 Rev00 – © b2 electronics GmbH – Subject to change without notice. Metering AC TrueRMS Maximum display value Resolution Accuracy Output voltage measurement range DC Maximum display value Resolution...

 Open the catalog to page 3
HVA45 & HVA45TD datasheet-4

HVA45 & HVA45TD VLF high voltage test set Datasheet Further characteristics AC supply 100 ... 240 V, 50/60 Hz, 1.200 VA Backfeed protection: 12 kV at 50/60 Hz DDD Dual Discharge Device (integrated electronic and mechanical discharge device) Product safety Environmental conditions Data transfer Report management PC software Dimensions L x W x H Weight Operating -20 ... +55 °C temperature range Storage -25 ... +70 °C temperature range Humidity 5 ... 85%, non condensing USB type A Bluetooth Built-in memory: up to 50 reports, 50 test sequences USB flash drive: dependent on storage capacity b2 ControlCenter...

 Open the catalog to page 4

All B2 electronics GmbH catalogs and technical brochures

  1. PDTD68

    3  Pages

  2. HVA68TD EN

    4  Pages

  3. PD30-E

    4  Pages

  4. PDTD60-2

    4  Pages

  5. PDTD90-2

    4  Pages

  6. PDTD120-2

    4  Pages

  7. BA100

    2  Pages

  8. TD90-MC

    2  Pages

  9. TD60-MC

    2  Pages

  10. TD120-MC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.