HVA120 datasheet

HVA120 datasheet

HVA120 datasheet

Product catalog summary
Overview: The HVA120 VLF High Voltage Test Set is designed for testing medium voltage cables up to 69 kV, with capabilities extending to 85 kVrms and 120 kVpeak. It is compact, portable, and offers a high power-to-weight ratio, making it ideal for field use.
Key Features:
  • Pure sinusoidal output voltage, independent of load.
  • Sheath fault pinpointing capability (requires additional locator).
  • Exchangeable HV test lead and real-time oscilloscope display.
  • Programmable test sequences and USB report downloads.
Performance and Safety:
  • Continuous duty cycle with no thermal limitations.
  • Dual discharge devices for safety and integrated transient protection.
  • Robust HV connectors for various test lead lengths.
Technical Specifications:
  • Output voltage: VLF sine wave up to 85 kVrms / 120 kVpeak, DC up to ±100 kV.
  • Output load: 0.5 μF at 0.1 Hz at 85 kVrms.
  • Output current: AC max 56 mArms, DC max 80 mA.
  • Sheath test voltage: 0 to 10 kV (negative polarity).
  • Operating temperature: -5 to +45 °C, storage temperature: -25 to +70 °C.
Compliance and Standards:
  • VLF withstand testing compliant with IEEE 400.2 and DIN VDE standards.
  • AC and sheath testing compliant with IEC standards.
Additional Features:
  • Data transfer via USB and RS232, with built-in memory for up to 50 reports.
  • PC software included for report management and control.
Included Accessories:
  • HV test lead, earth lead, power cord, manuals, data storage device, and more.
Optional Accessories:
  • Discharge stick, transport case, and diagnostic systems for Tan Delta and Partial Discharge.
See more

Catalog excerpts

HVA120 datasheet-1

HVA120 VLF high voltage test set Datasheet The HVA120 is a perfectly suitable test set to determine the condition of medium voltage cables with a voltage rating up to 69 kV (acc. to IEEE 400.2-2013). Its compact design and unmatchable high voltage output power to weight ratio is second to none on the market and makes it an excellent option for cable testing up to 85 kVrms and 120 kVpeak (sine wave operation). Beside the VLF and DC testing, the HVA120 performs also sheath testing with sheath fault location mode (here, however, additional fault probe is needed). Performance: Outstanding features considering size and weight vs. output load. Duty cycle: No thermal limitation! You can use the test set continuously. Safety first: Two independent discharge devices (electronic and mechanical discharging) and an integrated 12 kV transient protection system (at 50/60 Hz). Connectivity: On-site, no external PC is needed. All results can be later downoaded via USB for further l investigation and easy reporting via the b2 ControlCenter. Solid HV connectors: Robust HV connectors allow the use of various HV test lead lengths, quick exchange of a replacement cable, or a simpler upgrade path for connection of diagnostics systems. Output voltage Output load DHV1447 Rev00 – © b2 electronics GmbH – Subject to change without notice. YOUR BENEFITS TD AND PD DAGNOSTICS HVA120 can be extended to a complete cable diagnostic system at any time. DRY SYSTEM HVA test sets are constructed with nonarcing contacts and no need to change oil. This eliminates routine servicing and makes the test sets almost maintenance-free. UNLIMITED OPERATING TIME HVA generators are designed for continuous operation without any thermal limitations. COMPACT AND PORTABLE Our HVA series have been designed for maximum portability and on-site use. It makes them widely applicable for in-field use. • Pure sinusoidal output voltage (load-independent) • Sheath fault pinpointing in combination with sheath fault locator (not included) • Easily exchangeable HV test lead • Breakdown voltage and load detection • Real time oscilloscope of the output voltage on the HVA display • Programmable test sequences with a tailor-made software tool • Report downloads from the device via USB flash drive

 Open the catalog to page 1
HVA120 datasheet-2

HVA120 VLF high voltage test set Datasheet TECHNICAL DATA Output characteristics Output voltage Output current VLF sine wave DC VLF square wave Sheath test Voltage setting resolution AC frequency range Frequency setting resolution AC DC Sheath test trip current Sheath fault location Duty cycle 0 ... 85 kVrms / 0 ... 120 kVpeak -100 kV ... 100 kV 0 ... 100 kV 0 ... 10 kV (negative polarity) 0.1 kV 0.01 Hz ... 0.1 Hz 0.01 Hz 56 mArms max. 80 mA max. 0.1 ... 5 mA 40 mA max. Continuous, no thermal limitation of operating time DHV1447 Rev00 – © b2 electronics GmbH – Subject to change without notice....

 Open the catalog to page 2
HVA120 datasheet-3

HVA120 VLF high voltage test set Datasheet High voltage tests (continued) Manual mode Automatic test sequences (user definable) Burn on arc Trip out on arc VLF withstand testing according to IEEE 400.2 and the test standards DIN VDE 0276-620 (CENELEC HD 620 S2), DIN VDE 0276-621 (CENELEC HD 621 S1) AC and sheath testing according to IEC 60502-2 / IEC 60229 Test modes Arc management modes DHV1447 Rev00 – © b2 electronics GmbH – Subject to change without notice. AC TrueRMS Maximum display value Resolution Accuracy Output voltage measurement range DC Maximum display value Resolution Accuracy AC...

 Open the catalog to page 3
HVA120 datasheet-4

HVA120 VLF high voltage test set Datasheet Further characteristics USB type A RS232 Built-in memory: up to 50 reports, 40 test sequences USB flash drive: dependent on storage capacity b2 ControlCenter (included) HVA ControlCenter (included) 790 x 445 x 740 mm 31.1 x 17.51 x 29.1 in 198 kg / 436.5 lbs Data transfer Report management PC software Dimensions L x W x H Weight SCOPE OF SUPPLY Art. No. HVA120 VLF High Voltage Test Set Included accessories HVA120 HV test lead 160 kV PD 10 m MC14 Earth lead 5 m 16 mm2 transparent M6/clamp Power chord country specific - Unit side C19 HVA language specific...

 Open the catalog to page 4

All B2 electronics GmbH catalogs and technical brochures

  1. PDTD68

    3  Pages

  2. HVA68TD EN

    4  Pages

  3. PD30-E

    4  Pages

  4. PDTD60-2

    4  Pages

  5. PDTD90-2

    4  Pages

  6. PDTD120-2

    4  Pages

  7. BA100

    2  Pages

  8. TD90-MC

    2  Pages

  9. TD60-MC

    2  Pages

  10. TD120-MC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.