Data Sheet Vrms ( Cat II ) and 20 Arms direct input ranges The 5335C is a compact, single-phase AC / DC power meter for measuring and analyzing power consumption and power quality parameters quickly and accurately. It supports power measurements up to 600 Vrms and 20 Arms, with a bandwidth up to of 100 kHz. Applications Measure power, electrical energy bought or sold back to the power grid, inverters, harmonics of motors, un-interruptible power supplies, appliances, and consumer electronics. basic accuracy for voltage and current Rich Measurement Functions Measure all AC and DC parameters, including power, current, voltage, power factor, frequency, and phase. Additionally, the meter features a powerful integration function, the ability to perform harmonic measurements to the 50th order and an oscilloscope mode for viewing voltage and current readings in the time domain. 12 real-time parameters can be measured and displayed simultaneously in user customizable views. measurement parameters n Capture inrush current, and voltage surge with the peak function n Harmonic function with automatic range to measure electrical energy which is produced or consumed n Pre-compliance and frequency filter capability for reducing unwanted signal noise n Optional universal breakout box to simplify connection between power meter and DUT Basic voltage and current accuracy Technical data subject to change © B&K Precision Corp. 2021 Measurement range Voltage Input bandwidth Voltage, Current, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, V Max/V Min, A Max/A Min, Crest factor, Integration, Harmonic distortion factor, Total harmonic distortion (THD)
Open the catalog to page 1Flexible operation Integration measurement Harmonic measurement Voltage, current, active power, reactive power and phase values of each harmonic can be measured and displayed as a list or bar chart, enabling the user to quickly visualize and analyze the results. Total harmonic distortion (THD) can be evaluated up to the 50th order with the ability to display individual harmonic components. Current sensor input The integration function is useful for analyzing bought and sold electrical energy of a grid tied power systems. The 5335C meter provides current integral and active power integral...
Open the catalog to page 2Front panel USB host port Power button Main measurement function keys Rotary control knob Navigation keys Menu keys Intuitive user interface The large 4.3 inch color LCD screen enables easy viewing of configuration and measurements. Use the dedicated function keys to select one of the 4 main measurement modes: meter, harmonic, integral or oscilloscope. The results are displayed in numeric and graphical format. Screenshots can be saved directly to a USB flash drive. Rear panel USB LAN interface interface Current input terminals Voltage input terminals External sensor interface Trigger input
Open the catalog to page 3Specifications Specifications are subject to the following conditions Temperature: 23±5° C, humidity: 30 to 75% RH. Warm-up time: 30 minutes Model General Measurement Specifications Voltage, Current Power Basic measurements Peak to peak, Maximum, Minimum, Average_rms, Average_rectified, DC, Crest factor (current), Inrush (current) Real, Apparent, Reactive, DC, Power factor Total power, Total current, Maximum power, Minimum power Current, Voltage, Real power, Apparent power, Reactive power, Power factor, Phase, Percentage of total (Current, Voltage, Power) Harmonic measurements Frequency,...
Open the catalog to page 4Specifications (cont.) Current Measurement Accuracy and Ranges Direct input range Sensor input range Accuracy 2 (line, frequency, & digital filter set to off) 5 µA/ °C (after zero-level compensation, or range change) 500 µA/ °C (after zero-level compensation, or range change) Influence of internal sensor self-heating 2 2 2 + 0.00013 × I % of reading to the AC current accuracies + 0.00013 × I % of reading + 0.004 × I mA (0.5 to 20 A) or 0.00013 × I2 % of reading + 0.00004 × I2 mA (2.5 to 200 mA), add to the DC current accuracy specifications Power Measurement Accuracy Real power accuracy...
Open the catalog to page 5Specifications (cont.) Harmonic Measurement Parameters Measurement method Frequency range PLL frequency source range 10 Hz to 1.2 kHz (typical) Window function Fundamental frequency (Fund. freq.) Upper limit of analysis orders Window width Sample rate Harmonic Measurement Accuracy (when line filter is off) Oscilloscope Function Sample rate Record length Horizontal scale (Accuracy ±4.0%) Vertical scale ranges (Accuracy ±4.0%) Maximum input voltage (DC+AC peak) Maximum input current (DC+AC peak) Electromagnetic compatibility Remote Interfaces Standard Accessories Power Consumption Getting...
Open the catalog to page 6About B&K Precision For more than 70 years, B&K Precision has provided reliable and value-priced test and measurement instruments worldwide. Our headquarters in Yorba Linda, California houses our administrative and executive functions as well as sales and marketing, design, service, and repair. Our European customers are most familiar with B&K through our French subsidiary, Sefram. Engineers in Asia know us through our B+K Precision Taiwan operation. The independent service center in Singapore services customers in Singapore, Malaysia, Vietnam, and Indonesia. B&K Headquarters Yorba Linda,...
Open the catalog to page 7All B&K Precision catalogs and technical brochures
-
2023 New Products Catalog
16 Pages
-
394B Process Multimeter
5 Pages
-
Bench LCR Meter Model 891
6 Pages
-
DAS220-BAT
5 Pages
-
DAS30 / DAS50 / DAS60
6 Pages
-
1696B, 1697B & 1698B
3 Pages
-
8500B
7 Pages
-
2680
6 Pages
-
Dual K-type Thermometer
1 Pages
-
9110 & 9111
1 Pages
-
1651A & 1652
1 Pages
-
Models 1685B, 1687B & 1688B
3 Pages
-
Model 1692
1 Pages
-
Models 167x A
1 Pages
-
XLN series
5 Pages
-
9800 series
5 Pages
-
In-Circuit ESR Tester
1 Pages
-
Digital Milli-Ohm Meter
1 Pages
-
Dual Input Thermometer
1 Pages