Digital Multimeters 5½ & 6½ Digit 5490C Series
10Pages

{{requestButtons}}

Catalog excerpts

Digital Multimeters 5½ & 6½ Digit 5490C Series - 1

Data Sheet Digital Multimeters 5½ & 6½ Digit * GPIB model option The 5490C Series 5½ and 6½-digit bench multimeters are designed for accuracy, repeatability and ease-of-use. A wide measurement range with speeds up to 1000 readings per second, and a basic DCV accuracy up to 35 ppm deliver stable measurement results quickly and accurately. These general purpose meters are well suited for demanding engineering, production and service applications. For remote communication, this series includes standard LAN, USB (USBTMC-compliant) and RS232 interfaces, as well as a GPIB option. A LabVIEWTM driver is provided to simplify system integration and instrument control. The front panel USB host port can be used for transferring screen captures and measurement data, logged with date and time stamp, from the multimeter's internal memory to a computer. The multimeters feature simple and intuitive switching between the 12 measurement functions and display modes for a variety of test setups. Display modes include bar meter, trend chart, and histogram which can be combined with statistics or math functions. The dual measurement feature enables the simultaneous display of 2 measurements, e.g. AC voltage and frequency. Additionally, Limit mode and Probe hold mode allow users to conveniently verify and compare readings. Operating software Features and benefits measurement functions: DCV, ACV, DCI, ACI, 2 and 4-wire resistance, capacitance, frequency, diode, temperature, continuity test, DCV Ratio n 12 n Histogram, bar meter, and trend chart offer a variety of data analysis options n Accurate n Display Min, Max, Peak-Peak, Average, Standard Deviation statistics simultaneously n Null, dB, dBm, %, mx+b, and run/stop math functions n Internal storage buffer holds 10,000 readings The provided operating software supports remote instrument control, live measurement monitoring, and data logging. ppm basic DC voltage accuracy n 2-wire and 4-wire resistance measurements down to 10 Ω n Dual measurement display n Temperature measurement capability using a Pt100 or 5 kΩ thermistor probe Displayed Digits DC Voltage basic accuracy Rear input terminals n Rear input terminals for rack use (6½-digit model only) n Standard USB (USBTMC-compliant), RS232, and LAN interfaces, GPIB option n Real-time clock/calendar to set/read time and date Technical data subject to change © B&K Precision Corp. 2020

Open the catalog to page 1
Digital Multimeters 5½ & 6½ Digit 5490C Series - 2

Digital Multimeters 5490C Series Front panel USB host Save and recall settings, transfer screen captures, export measurement data files 4.3-inch, high contrast, adjustable brightness Function keys Quickly cycle between different measurement modes Input terminals Rear panel Rear input terminals 6½-digit models only External trigger Trigger input to synchronize with other events and instruments Optional GPIB interface Remote interfaces LAN, USB (USBTMC-compliant) and RS232 interfaces standard

Open the catalog to page 2
Digital Multimeters 5½ & 6½ Digit 5490C Series - 3

Digital Multimeters 5490C Series Powerful measurement tools Multiple measurement and display options Versatile math functions Dual measurement display In addition to statistical data and limit test mode, this series is capable of Null, dB, dBm, mX+b, run/stop, and percent calculation functions. Simultaneously display multiple measurements such as frequency and AC voltage. DC voltage ratio measurement Probe hold mode Displays the ratio between two separate DC voltage measurements within ±12 Volts. This function is useful to quickly verify the difference between input and output magnitudes of...

Open the catalog to page 3
Digital Multimeters 5½ & 6½ Digit 5490C Series - 4

Digital Multimeters 5490C Series Specifications - 5492C / 5492CGPIB Specifications are based on the following conditions: - One year calibration cycle - Calibration temperature TCAL = 23 °C - Accuracy specifications: ± (% of reading + % of range), valid for TCAL ±5 ºC - For DC: The technical specifications are valid after a warm-up time of 60 minutes, with the integration time set to 10 or 100 NPLC, and auto zero enabled. - For AC: The technical specifications are valid after a warm-up time of 60 minutes, slow AC filtering enabled, using a sine wave input signal. Full Scale Reading Burden...

Open the catalog to page 4
Digital Multimeters 5½ & 6½ Digit 5490C Series - 5

Digital Multimeters 5490C Series True RMS AC Voltage(1)(2) 100 mV, 1 V, 10 V, 100 V, and 750 V ranges Accuracy (1 Year) Full Scale Reading (1) Valid for sine wave input > 0.3% of range and greater than 1 mVrms. (2) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (3) 20% overrange on all ranges except 750 V range can only test 5% overrange. (4) 750 V range is limited to 8 x 107 Volt-Hz. Burden Voltage Full Scale Reading (5) Three filters are available for low-frequency...

Open the catalog to page 5
Digital Multimeters 5½ & 6½ Digit 5490C Series - 6

Digital Multimeters 5490C Series Specifications - 5493C / 5493CGPIB Specifications are based on the following conditions: - One year calibration cycle - Calibration temperature TCAL = 23 °C - Accuracy specifications: ± (% of reading + % of range), valid for TCAL ±5 ºC - All 24 hours accuracy specifications are typical - Add temperature coefficient for every ºC outside TCAL ±5 ºC - For DC: The technical specifications are valid after a warm-up time of 60 minutes, with the integration time set to 10 or 100 NPLC, and auto zero enabled. - For AC: The technical specifications are valid after a...

Open the catalog to page 6
Digital Multimeters 5½ & 6½ Digit 5490C Series - 7

Digital Multimeters 5490C Series Full Scale Reading True RMS AC Voltage(2)(3) 100 mV, 1 V, 10 V, 100 V, and 750 V ranges Frequency Full Scale Reading (2) Valid for sine wave input > 0.3% of range and greater than 1 mVrms. (3) Three filters are available for low-frequency performance: 3 Hz, 20 Hz, and 200 Hz. No additional errors will occur for frequencies above these filter settings. (4) 20% overrange on all ranges except 750 V range which can only test 5% overrange. (5) 750 V range is limited to 8 x 107 Volt-Hz. Continuity Range Test Current Accuracy 24 Hours TCAL ± 1°C Test Current...

Open the catalog to page 7

All B&K Precision catalogs and technical brochures

  1. DAS220-BAT

    5 Pages

  2. 8500B

    7 Pages

  3. 2680

    6 Pages

  4. 9110 & 9111

    1 Pages

  5. 1651A & 1652

    1 Pages

  6. Model 1692

    1 Pages

  7. XLN series

    5 Pages

  8. 9800 series

    5 Pages

Archived catalogs