Catalog excerpts
Data Sheet The 9240 Series sets a new standard for general purpose DC power supplies by including many features and capabilities found in high performance instruments as standard. The multi-range operation provides up to 200 W of clean output power in any Volt/Amp combination within the rated voltage and current limits. This series combines an easy-to-use interface with advanced list programming features, battery charge mode, and data logging to serve a wide range of applications including production test, R&D, electronic service, and education. Intuitive list mode programming makes it easy to set up and execute complex test sequences directly from the front panel. Advanced list mode features include the ability to output multiple user-defined list mode programs in sequence and step triggering for synchronizing the power supply's output with external events. The 9240 Series battery charge mode provides configurable fail-safe settings to disable the output when a specified energy, capacity, or time threshold is reached protecting both the power supply and battery. Battery charge data including Wh, Ah, and time can be logged directly to a USB flash drive connected to the front panel USB host port. User-configurable battery charge profiles, instrument settings, and list mode programs can also be saved/recalled from the USB host port. This series offers system integrators with LXI compliant LAN and USB (USBTMC-compliant) interfaces standard for remote control and programming with a GPIB model option. The provided LabVIEW™, IVI-C, and IVI.NET drivers further simplify system development and integration. In addition to OVP, OCP, and OTP protections, these power supplies support remote inhibit and voltage fault features to protect both the power supply and device under test (DUT). Features and benefits ■ Isolated and floating output with front panel remote sense ■ Up to 120 W or 200 W of multi-range power in a compact 2U half-rack form factor ■ Clean output power with less than 1 mVrms of noise ■ Advanced list mode programming with internal storage for 10 list mode programs ■ Battery charge mode with fail-safe conditions ■ Direct data logging to a USB flash drive ■ Thermostatically-controlled fan for quiet operation ■ Adjustable voltage and current slew rate ■ Built -in web server for control of basic power supply settings ■ LED test mode for protecting components from inrush currents ■ Oscilloscope-like display mode to graphically monitor voltage and current readings ■ Digital I/O terminal offers external triggering, voltage fault and remote inhibit capabilities ■ Overvoltage (OVP), overcurrent (OCP), overtemperature (OTP) protection, and key-lock function ■ NISPOM sanitization to securely reset to factory settings ■ USB (USBTMC-compliant and virtual COM) and LXI compliant LAN interfaces standard, GPIB optional ■ LabVIEW™, IVI-C, and IVI.NET drivers provided ■ Remote PC control software available ■ Convenient front-panel user calibration ■ cTUVus certification mark fulfills CSA and UL safety standards Technical data subject to change © B&K Pr
Open the catalog to page 1Multi-Range DC Power Supplies 9240 Series Operation highlights Advanced list mode The 9240 Series list mode programming features are useful for repetitive testing or other applications requiring a specific sequence of voltage and current settings. The illustration below highlights some of the configurable options for setting up a list mode program. 1 To help control inrush current, the voltage slew rate is adjustable from 0.005 V/ms to 3.2 V/ms. The current slew rate is also adjustable from 1 mA/ms to 1000 mA/ms. 2 Dwell (step duration) can be set from 0.1 s to 9999 s. 3 BOST / EOST...
Open the catalog to page 2Multi-Range DC Power Supplies 9240 Series Battery charge mode The dedicated battery charge mode offers many user-configurable charge parameters and fail-safe conditions to simplify battery charging. Charge parameters: • Charge voltage set (V Full) • Charge current limit (I Limit) • Charge termination current (I End) • Charge end delay (End Delay) Battery Charge Mode 13.794V 0.285A0.03 Ah 0.42 Wh Fail safe settings: • Stop time • Stop Ah • Stop Wh V Full 13 800 V I Limit 1 200 A I End 0100 a End Delay 010 s Battery charge configuration menu Battery data logging and charge profiles Log...
Open the catalog to page 3Multi-Range DC Power Supplies 9240 Series The tools you need: on the bench or in the rack Operating software Test system integration • LXI compliant LAN, USBTMC-compliant/USB Virtual COM Port selectable, and GPIB model option • LabVIEWTM, IVI-C, and IVI.NET drivers simplify system development and integration • Digital I/O terminal with remote inhibit and voltage fault protection • Rear panel output terminal with remote sense The provided PC software makes it easy to control and monitor the power supply remotely without the need to write source code. NISPOM sanitization The 9240 Series...
Open the catalog to page 4Multi-Range DC Power Supplies 9240 SeriesFront panel 4.3-inch LCD Clearly displays set and measured voltage, current, and power parameters USB host Save/Recall instrument settings and list mode programs, log data directly to an external flash drive Intuitive control Numeric keypad and rotary knob for precise control 60.000V 0.190A _ 11.75W Vset Bi!lTl!l?ll V Iset 0.500 A OnDelay 0.000 s Vmax 60.600 V Vmin 0.000 V OffDalay 0.000 s Output control Dedicated output on/off button Mechanical power button Gives tactical feel and prevents standby power draw Multi-type output and sense terminals...
Open the catalog to page 5Specifications Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C. Specifications are valid for front panel operation. Regulatory Compliance (1) With remote sense terminal connected. (2) From 10% to 90% or from 90% to 10% of total voltage excursion. (3) Time for output voltage to recover within 0.5% of its rated output for a load change 50-100% of full load. (4) Typical time required for output to begin to change following receipt of command data. (5) Tested and certified by a Nationally...
Open the catalog to page 6All B&K Precision catalogs and technical brochures
-
2023 New Products Catalog
16 Pages
-
394B Process Multimeter
5 Pages
-
Bench LCR Meter Model 891
6 Pages
-
Power Meter 5335C
7 Pages
-
DAS220-BAT
5 Pages
-
DAS30 / DAS50 / DAS60
6 Pages
-
1696B, 1697B & 1698B
3 Pages
-
8500B
7 Pages
-
2680
6 Pages
-
Dual K-type Thermometer
1 Pages
-
9110 & 9111
1 Pages
-
1651A & 1652
1 Pages
-
Models 1685B, 1687B & 1688B
3 Pages
-
Model 1692
1 Pages
-
Models 167x A
1 Pages
-
XLN series
5 Pages
-
9800 series
5 Pages
-
In-Circuit ESR Tester
1 Pages
-
Digital Milli-Ohm Meter
1 Pages
-
Dual Input Thermometer
1 Pages