1. Catalogs
  2. b+b Automations- und Steuerungstechnik GmbH
  3. KNX Modbus Gateway (DIN rail housing)
video corpo

KNX Modbus Gateway (DIN rail housing)
1 /1Page

KNX Modbus Gateway (DIN rail housing)

KNX Modbus Gateway (DIN rail housing)
1 /1Page

Catalog excerpts

KNX Modbus Gateway (DIN rail housing)-1

compatible devices Highlights • Direct link to EIB/KNX (two-wire) • Link to Modbus RTU (RS-485 or RS-232) • Read & write values from electric meters, electricity supply systems, etc. • Support for all major Modbus Function codes: Read Coils, Read Discrete Inputs, Read Holding Registers, Read Input Registers, Write Single Coil Write Singl Register, Write Multiple Coils, Write Multiple Registers • Cyclic polling of the slaves • Each KNX Modbus Gateway can transfer up to 300 measured values • Up to 30 Modbus devices (at RS-485) can be connected to each KNX Modbus Gateway • KNX status message in case of a Modbus Slave failure • Simple parametrization via USB and b+b Terminal software • DIN rail housing (6TE = 105mm) with integrated 100V - 240V wide range power supply Description The KNX Modbus Gateway is used for communication between the EIB/KNX bus and Modbus compatible meters, power analyzers, etc. The gateway assumes the role of the Modbus Master, i.e. it controls communication. The gateway provides a bidirectional connection. Data from the Slaves can be read either in cycles at certain intervals or on request by the EIB/KNX bus system. The most important function codes for read and write access are supported. For example, consumption values can be used as an integer or transferred as a floating point value to the EIB/KNX bus. Different data formats can be set for each measured value. Furthermore, it is possible to scale the process values (multiplication/division). Parametrization and diagnosis is performed through the integrated USB interfaces in connection with our b+b Terminal software. The gateway hardware consists of a 6TE (=105 mm) wide rail mounting housing with integrated 100V - 240V power supply and connections for Modbus & EIB/KNX. The device is maintenance-free without fan or any other wear parts. Fields of application • Integration of Modbus slaves for the professional performance-, power- and energy-analysis • Easy integration of Modbus RTU slave in EIB/KNX -systems • Read current process values of Modbus slaves • Visualization of energy consumption in the EIB/KNX installation Interfaces present • EIB/KNX 2-wire connection through standard EIB/KNX bus terminal • USB connection through Mini USB socket • Modbus connection through screw terminals (RS-485) and Sub-D (RS-232) • Modbus data rate of 1,2kBit/s to 38,4kBit/s Contents of delivery • KNX Modbus Gateway • USB cable for parametrization/diagnosis • b+b Terminal Software • Documentation errors and omissions excepted b+b Automations- und Steuerungstechnik GmbH Beerfelden Site I ■ DieselstraBe 18 ■ Airlenbach Site II ■ EichenstraBe 38a ■ 64760 Oberzent (Germany) phone: +49 (0) 6068 9310-0 ■ fax: +49 (0) 6068 9310-99 [email protected] ■ www.bb-automation.com

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.