PTG Series Smart Pressure Transmitters
40Pages

{{requestButtons}}

Catalog excerpts

PTG Series Smart Pressure Transmitters - 1

PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based on Azbil Corporation's proven Smart Transmitter technologies, the model PTG offers improved performance and reliability with size, weight and cost advantages. An optional, built-in digital indicator allows the pressure transmitter to be used in a wide variety of applications. The model PTG can also enable two-way communications between CommPad (Smart Communicator), or HART 375 communicator, and, via DE protocol, a TDCS3000 or 3000X and a database, thus facilitating self-diagnosis, range resetting, and automatic zero adjustment operations. CE mark Model PTG71G screw type Type of protection • Water and dust proof for IEC IP67 • FM Explosionproof • FM Dust-ignition-proof • FM Intrinsically safe • KOSHA Flameproof • NEPSI Flameproof • NEPSI Dust ignition-proof • ATEX Flameproof FEATURES Compact and lightweight • Approx. 0.9 kg (Screw connection type) Broad range setting • Range from -100 kPa to 50 MPa. • Span from 2.0 kPa to 50 MPa. Note) Screw connection type. Covered with five ranges. China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. Remote communication Any range can be set using the Smart communicator or the HART communicator (available separately). This further increases range flexibility and keeps inventory down. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. Built-in digital indicator The built-in digital indicator option effectively checks output on site. Specifications are subject to change without notice.

Open the catalog to page 1
PTG Series Smart Pressure Transmitters - 2

Azbil Corporation External views of the PTG series Model PTG7_G (Screw type) Model PTG7_B (Flush diaphragm type) Model PTG7_T (Remote seal with ferrule clamp type) Model PTG7_S (Ferrule clamp type) Model PTG7_K (Ferrule clamp type with cooling tower) Model PTG7_S (Ferrule cap nut type) Model PTG7_F (Flange type) Model PTG7_K (Ferrule cap nut type with cooling tower) Model PTG7_T (Remote seal with ferrule cap nut type)

Open the catalog to page 2
PTG Series Smart Pressure Transmitters - 3

Azbil Corporation COMMON SPECIFICATIONS Output / Communication Model PTG71 • Analog output (4 to 20mA DC) with SFN communication Explosionproof for Class I, Division 1, Groups A, B, C and D, T4, ambient temperature = 60°C Dust-ignition for Class II and III, Division 1, Groups E, F and G, T6 ambient temperature = 60°C, Type 4X Response speed FM Intrinsically safe approval Intrinsically safe for Class I, II, III, Division1, Group A, B, C, D, E, F, G T4 / Class I, Zone 0, AEx ia IIC T4 Vibration Tolerance • Analog output (4 to 20mA DC) with HART protocol • DE output with CommPad communication...

Open the catalog to page 3
PTG Series Smart Pressure Transmitters - 4

Azbil Corporation Oil and water free finish Oil and water are removed from the wetted parts before shipment. Electrolytic grinding (For ferrule type only) The surface of the wetted parts is smoothed by electrolytic grinding. Passive state finish (For ferrule type only) The surface of the wetted parts is treated with a passive state finish to form a protective film to increase resistance to corrosion. Test report The test report indicates the results of appearance, I/O characteristics, insulation resistance, and breakdown voltage tests. Material certificate The material certificate shows the...

Open the catalog to page 4
PTG Series Smart Pressure Transmitters - 5

Azbil Corporation Working range of negative pressure 1000 Normal operating range (T: - 40 C to -110 C) 100 Figure 3 Minimum working pressure for combination of model PTG__S or model PTG__T or model PTG__B or PTG__F and propylene glycol. Unusable range (T: 150 to 155 C) Unusable range (T: -20 to -10 C) 1000 Normal operating range (T: - 40 C to -110 C) Temperature at wetted parts: T ( C) Figure 2 Minimum working pressure for model PTG__G. Unusable range Normal operating range (T: 110 C to 125 C) (T: - 10 C to -110 C) Temperature at wetted parts: T ( C) Temperature at wetted parts: T ( C)...

Open the catalog to page 5
PTG Series Smart Pressure Transmitters - 6

Azbil Corporation Transmitter handling notes Handling precautions for HARTspecification devices To get the most from the performance this transmitter can offer, please use it properly noting the points mentioned below. Before using it, please read the Instruction Manual. • "If you need to operate with a secondary host (HART communicator, etc.), set the communication interval of the primary host (DCS, device management system) to 8 seconds or more, or suspend communication from the primary host. If the primary host repeats HART communication within 8 seconds, the request from the secondary...

Open the catalog to page 6
PTG Series Smart Pressure Transmitters - 7

Azbil Corporation Index of detailed specifications for process connection types Process connection Process connection style Measurement span Reference page Screw type PTG_G G3/8 external thread G1/2 external thread Rc3/8 internal thread Rc1/2 internal thread 1/2NPT internal thread M20 × 1.5 external 2.0 to 100 kPa {0.021 to 1.019 kgf/cm²} 40 to 400 kPa {0.408 to 4.07 kgf/cm²} 0.2 to 2 MPa {2.04 to 20.3 kgf/cm²} 1 to 10 MPa {10.20 to 101.9 kgf/cm²} Rc1/4 internal thread G1/2 external thread 1/4NPT internal thread M20 × 1.5 external thread 2.0 to 100 kPa {0.021 to 1.019 kgf/cm²} 40 to 400 kPa...

Open the catalog to page 7
PTG Series Smart Pressure Transmitters - 8

Azbil Corporation Screw type Ambient temperature limits Normal operating range Water and dust proof FM Explosion proof FM Intrinsically safe KOSHA Flameproof NEPSI Flameproof (Ex d II CT4, 5) ATEX Flameproof Transportation and storage conditions -30 to 80°C Temperature range of wetted parts Measuring span / Setting range / Max. working pressure Model no. Measuring span Setting Range Fill fluid Process Connection • Silicone oil (for general purpose models) • Fluorine oil (for oxygen and chlorine models) Wetted parts Diaphragm SUS316L Case Aluminum alloy Process connection Zero temperature ±...

Open the catalog to page 8

All Azbil catalogs and technical brochures

  1. GTX00U

    36 Pages

  2. GTX00F

    20 Pages

  3. GTX00A

    12 Pages

  4. GTX00G series

    20 Pages

  5. GTX00D series

    24 Pages