Group: Azbil
Catalog excerpts
Compact Die-Cast Limit Switches with Positive Opening Mechanism ® @ C € © EN-compliant switches, meeting global standards. Switches certified to meet EN, UL and CSA standards ■ With UL/CSA/CE marking ■ Cabling both lengthwise and crosswise from the switch is possible, allowing reduced stress on the cable. forced open
Open the catalog to page 1SPECIFICATIONS Standards Product related: IEC 60947-5-1 , EN 60947-5-1 , Machine related: IEC 60204-1, EN 60204-1 Compliance Certification Ingress protection Electrical shock protection Pollution degree Internal switch Electrical rating Insulation resistance Electrical performance Mechanical performance Rated thermal current (Ith) Short-circuit protection Rated insulation voltage (Ui) Conditional rated short-circuit current Rated impulse withstand voltage (Uimp) Impact resistance IP66, IP67 (IEC 60529, JIS C 0920) class I (IEC 61140) 3 Slow action: 1N.C.+1N.O.(BBM) AC-15; B300 (Ue=240V,...
Open the catalog to page 2OPERATING CHARACTERISTICS AND EXTERNAL DIMENSIONS Metal roller plunger: LJM-D2502L 11.6 dia. x 3.5 width, Sintered stainless steel (SUS303) Vertical operating characteristics BK/WH-BK BU-BN Contacts open Contacts closed (P) = min. travel to positive opening position 7.5 O.F. (max. operating force needed for N.C. operation) (N max.) P.T. (pretravel) (mm) N.C.:(1.8), N.O.:(2.6) (5) T.T. (total travel) (mm) P.O. (min. travel to positive opening position) (mm min.) 3.1 P.O.F. (min. force for positive opening) (N min) 42.5 Note 1. Housing is made of zinc alloy painted blue. Note 2. Cable is...
Open the catalog to page 3■ Always tighten each part of the safety switch to the tightening torque recommended in the product specifications. Tightening any part excessively, might damage the threads and/or other parts ■ Mount the dog so that no force is directly applied to the actuator in the free state ■ Do not use silicone adhesive or silicone grease. Doing so might result in faulty electrical contact ■ Do not do wiring work with the power ON. Doing so might cause an electrical shock or cause the device to operate unexpectedly ■ Do not apply excessive force (5 times larger than the O.F.) to the actuator when it...
Open the catalog to page 4All Azbil North America catalogs and technical brochures
-
NX-D25
2 Pages
-
NX-CB2
1 Pages
-
NX-CL1/CL2/TL1/TR1
1 Pages
-
RN748A
1 Pages
-
HM
1 Pages
-
ECM3000 Control Motor
8 Pages
-
Multi-Loop Controller SDC46A
2 Pages
-
Single Loop Controller SDC25
2 Pages
-
Single Loop Controller SDC15
2 Pages
-
YYU4 Simple Thermocouple
1 Pages
-
Fiber Units HPF Series
26 Pages
-
FL2 Series
6 Pages
-
BZ Series Basic Switch
9 Pages
-
CMG Series Gas Flow Monitor
4 Pages
-
MCF Series Air Flow Meter
2 Pages
-
MAGNEW Series
3 Pages
-
HP100
10 Pages
-
HPX
10 Pages
-
HPX-AG
20 Pages
-
APT
2 Pages
-
APM
6 Pages
-
FL7M
10 Pages
-
ATT70
8 Pages
-
WaterMAG
8 Pages
Archived catalogs
-
MagneW 3000 Plus CA2-MGG-01
4 Pages
-
MagneW 3000 PLUS HENRI
2 Pages
-
MagneW Two-Wire Plus
20 Pages