Group: Azbil
Catalog excerpts
Digital Fiber-Optic Sensors C t ®— Easy operation and high performance
Open the catalog to page 1Advanced scanning performance for expanded possibilities •High sensitivity and ultra long distance ©Five selectable sensing modes • High accuracy detection •Countermeasures for short-distance saturation I s™irYiw «wnnHit I •Superior auto-tuning
Open the catalog to page 2Easy-to-use design
Open the catalog to page 3►Superior timer functions The advanced functions of the HPX-AG's combination timer go beyond the standard on-delay/off-delay functions and the newer one-shot timer function. Timer setting time Time chart—LO (light ON) ►Peak/bottom display Since peak and incoming light levels are displayed at the same time, the light axis can be aligned precisely. light axis alignment (Mutual interference prevention function With optical communications, mutual interference between sensors can be prevented. Pack up to 8 units closely together! closely mounted together. light level display modes Selectable...
Open the catalog to page 4Optimum sensors for a variety of applications
Open the catalog to page 5REFERENCE DATE FOR TARGET DETECTION (Be sure to test using an actual target object.) Standard diffuse scan fiber Glass substrate Standard thru scan fiber unit Glass substrate HPF-D002 Sensing mode: HP3 HPF-T003 Sensing mode: HP3 Incoming light level Incoming light level characteristics of glass substrate and wafer 100000 Basic glass Vapor deposition glass Black mask 10000 Edge detection repeatability accuracy 1000 100 0 5 10 15 20 25 30 35 40 45 mm Black mask On remote tuning models, if tuning is repeated before sensing, the repetition accuracy can be further increased. Fiber unit with...
Open the catalog to page 7■ AMPLIFIER SELECTION GUIDE
Open the catalog to page 8* Operating temperature is different depending on the number of gang-mounted sensor units. 1 or 2 units: -20 to +55°C, 3 units: -20 to +50°C, 4 or 5 units: -20 to +45°C, 6 units: -20 to +40°C The HPX-AG06 (2-setting and 2-output model) and HPX-AG07 (zone setting model) do not have Fast or High Speed response time (sensing type) settings. After Semi Fast, the next fastest speed is Semi High Speed (140^s). Forthe response time of the HPX-AG08 (differential setting model), please contactYamatake Corporation.
Open the catalog to page 9C^uHable)th Bend radius Catalog listing Fine diameter Fine diameter Fine diameter Small diameter long scanning distance Elastic small Elastic standard Glass fiber cold resistant from ;Lens incorporated) Parallel beam ;i_ens incorporated) Parallel beam side view Narrow beam Narrow beam side view For the HPX-AG06 (dual output, dual set values) and HPX-AG07 (active zone setting), the FT3 and HS3 sensing modes (for response speed) are not available. The sensing mode faster than SF3 is SH3, with approx. 35% of the sensing distance of nl_3. For the response time of the HPX-AG08 (differential...
Open the catalog to page 11Group Appearance Sensing type Features Cable length (cuttable) Limited reflection Scanning distance (mm) Free cut 2m Bend radius Catalog listing HP3 nL3 HPF-D028T SF3 FT3 Limited reflection HS3 HP3 R15 nL3 HPF-D028F SF3 FT3 HS3 Wet process Group Appearance Sensing type (Built-in lens) Scanning distance (mm) nL3 SF3 5 13.7 FT3 Core: 3 dia. (effective lens dia.)(1) 4.7 dia. 580 HS3 1,030 HP3 14.8 Oil and chemicalproof 5 HS3 HP3 nL3 SF3 16 FT3 6 dia. Core: 1 dia. (2) HS3 PFA tube small diameter Bend radius 300 140 190 130 95 60 25 Pipe-mounted. Light received when liquid present. 3 to 13mm...
Open the catalog to page 15I CHARACTERISTICS DIAGRAMS (typical eiamples
Open the catalog to page 16■ SCANNING DISTANCE WHEN USED WITH ATTACHMENT
Open the catalog to page 17■ HPX-AG REFERENCE MANUAL
Open the catalog to page 20All Azbil North America catalogs and technical brochures
-
NX-D25
2 Pages
-
NX-CB2
1 Pages
-
NX-CL1/CL2/TL1/TR1
1 Pages
-
RN748A
1 Pages
-
HM
1 Pages
-
ECM3000 Control Motor
8 Pages
-
Multi-Loop Controller SDC46A
2 Pages
-
Single Loop Controller SDC25
2 Pages
-
Single Loop Controller SDC15
2 Pages
-
YYU4 Simple Thermocouple
1 Pages
-
Fiber Units HPF Series
26 Pages
-
FL2 Series
6 Pages
-
LJM-D series
4 Pages
-
BZ Series Basic Switch
9 Pages
-
CMG Series Gas Flow Monitor
4 Pages
-
MCF Series Air Flow Meter
2 Pages
-
MAGNEW Series
3 Pages
-
HP100
10 Pages
-
HPX
10 Pages
-
APT
2 Pages
-
APM
6 Pages
-
FL7M
10 Pages
-
ATT70
8 Pages
-
WaterMAG
8 Pages
Archived catalogs
-
MagneW 3000 Plus CA2-MGG-01
4 Pages
-
MagneW 3000 PLUS HENRI
2 Pages
-
MagneW Two-Wire Plus
20 Pages