Single Loop Controller Model C1M - 1

Dimensions Input group selectable by model No. (thermocouple, RTD, DC voltage/current). Refer to “Input Types and Ranges” 50, 100, 300, 500 ms (selectable by setting) ±0.2% FS ±1 digit (RTD input, DC voltage/current input) ±0.3% FS ±1 digit (thermocouple input) ON/OFF, time proportional PID, current proportional PID - Relay output: 1c (SPDT) 250 V AC / 30 V DC, 3 A - Voltage pulse output: 19 V DC ±15%, internal resistance 18 Ω, allowable current 24 mA DC max. - Current output: DC 0–20 mA, 4–20 mA (selectable by setting) Allowable load resistance 600 Ω max. Event Output No. of outputs Output type Event Type No. of inputs Functions 2 max. Auto/manual changeover, run/ready changeover, LSP set selection, PID set selection, etc. Compatible current transformers Protocols No. of connectable units Communication speed Connection type Cable length Ambient temperature Supply voltage Power consumption Standards compliance Protective structure Mass 2 inputs max. Separate purchase: CT model QN206A or QN212A CPL, Modbus/RTU compliant 31 units max. 38,400 bps max. USB loader cable (model 81441177-001) 2 m max. −10 to +55 °C (−10 to +45 °C for tight mounting) 100–240 V AC, 50/60 Hz 8 VA max. EN 61010-1, EN 61326-1 IP66 (front panel) 130 g (including mounting bracket) Loader Port General Single Loop Controller Rear (terminal side) Input Types and Ranges Sensor Sensor type Thermocouple K Model Selection Basic Add’l proc PV Specifications model Installation Control input Power Options output 1 2 No. Basic model No. C 1M Screw terminal block T Control output 1 Control output 2 Relay output (C.O. contacts) None R 0 Voltage pulse None V 0 Current Voltage pulse V C Voltage pulse Voltage pulse V V Current None C 0 Current Current C C Thermocouple input T RTD input R DC voltage/current input L AC power supply (100–240 V) A None 0 0 3 event outputs 0 1 3 event outputs, 2 CT inputs, 2 DIs 0 2 3 event outputs, 2 CT inputs, RS-485 comm. 0 3 2 event outputs (independent contacts) 0 4 2 event outputs (independent contacts), 2 CT inputs, 2 DIs 0 5 2 event outputs (independent contacts), 2 CT inputs, RS-485 comm. 0 6 RS-485 comm. 0 9 None 0 With inspection report D With traceability certificate Y 0 None *Available soon A UL compatible model Mounting bracket (included) 3 max. Relay output: 1a (SPST) PV high limit, deviation high limit, loop diagnosis, timer, heater disconnection, etc. Digital Input Control modes Output type (selectable by model No.) Control Output Type Range Sampling cycle Indication accuracy Range -200 to +500 ˚C -200 to +500 ˚C -200 to +200 ˚C -200 to +200 ˚C -100.0 to +300.0 ˚C -100.0 to +300.0 ˚C -50.0 to +200.0 ˚C -50.0 to +200.0 ˚C -50.0 to +100.0 ˚C -50.0 to +100.0 ˚C 0.0 to 200.0 ˚C 0.0 to 200.0 ˚C 0.0 to 500.0 ˚C 0.0 to 500.0 ˚C Scaling from −1999 to +9999 (decimal point position is variable) Note: 1. The accuracy of the B thermocouple and of the PR40-20 thermocouple differ from the “Indication accuracy” stated in the Specifications. 2. One decimal place is displayed for ranges that contain fractional values. Standards for input sensors • Thermocouple K, J, E, T, R, S, B, N: JIS C 1602-2015. PL II: Engelhard Industries documents (ITS90) WRe5-26: ASTM E988-96 (reapproved 2002). DIN U, DIN L: DIN 43710-1985 • Resistance temperature detector Software (Sold Separately) Model No. SLP-C1FJA0 Name & Specification Smart loader package (USB loader cable included) Note: The software can be downloaded for free from our website. https://www.azbil.com/products/factory/factory-product/controller-recorder-communication-gatewa y/controller/index.html Notes on the use of the PID simulator • The PID simulator simulates optimal operation of the control system. • Estimates from the PID simulator may not match actual control results depending on equipment characteristics (such as nonlinearity). • The PID simulator does not support heating/cooling control. * For more information, please contact one of our sales representatives. Name & Specification Terminal cover Soft cover Hard cover Panel mounting bracket for DIN rail Gasket (for model C1M maintenance) Mounting bracket (for model C1M maintenance) Current transformer (800 turns, hole dia. 5.8 mm) Current transformer (800 turns, hole dia. 12 mm) USB loader cable *Available soon *Available soon *Available soon Please read “Terms and Conditions” from the following URL before ordering and use. https://www.azbil.com/products/factory/order.html Ethernet is a trademark of FUJIFILM Business Innovation Corp. MELSEC is a trademark of Mitsubishi Electric Corporation. Modbus is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies. Other product names, model numbers and company names may be trademarks of the respective company. [Notice] Specifications are subject to change without notice. No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation. 1-12-2 Kawana, Fujisawa Kanagawa 251-8522 Japan URL: https://www.azbil.com 1st Edition : Feb. 2022-SO (16)

Open the catalog to page 1
Single Loop Controller Model C1M - 2

User-friendly and easy-to-use controller solves process control problems Large-screen LCD shows control status at a glance. New features have been added to help with PID adjustment and engineering. Improved smart loader package Liquid-crystal display The large 15.4-mm display (about 1.4 times larger than the previous model) shows the process value (PV) in bright white. This improves visibility in the field. A variety of other information can be displayed, allowing you to see the process control status at a glance. Useful in a variety of situations: setup, trial run adjustment, operation...

Open the catalog to page 2

All Azbil Europe NV catalogs and technical brochures

  1. V8C/V8S

    4 Pages

  2. F4Q

    6 Pages

  3. F7M

    4 Pages

  4. AT9000

    2 Pages

  5. HP series

    16 Pages

  6. GasCVD

    2 Pages