Group: azbil
Catalog excerpts
• A circle "o" denotes arailability. G' * Accessories (sold separately) Model No. • A circle "O" denotes arai lability. azbil Multi Loop Controller with Multi-Input Computation Function SDC45V/46V CE marking compliant ( EN61326 ^ Information about Standards Please read the "Terms and Conditions" from the following URL before ordering or use: http://www.azbil.com/products/bi/order.html V_"_) EMC Directive: Requires that the electromagnetism generated by the device does not interfere with the operation ol communications equipment, and that the device have a certain level ol resistance to electromagnetic Interference. EN 61326 applies EMC requirements to electric devices for measurement, control and testing. Low-Voltage Directive: Requires that devices are safe, that high-level engineering has been applied to ensure safety, and that the design has been made in accordance with the general rules recognized by EU member countries. EN61010-1 defines the safety requirements for electric equipment of measurement, control and test equipment (Part 1: general information). [Notice] Specifications are subject to change without notice. SDC is a registered trademark of Azbil Corporation in Japan. No part of this publication may be reproduced or duplicated Other product names, model numbers and company names may be trademarks of the respective company. without the prior written permission of Azbil Corporation. Azbil Corporation Advanced Automation Company Yamatake Corporation changed its name to Azbil Corporation on April 1,2012. 1-12-2 Kawana, Fujisawa Kanagawa 251-8522 Japan URL: http://www.azbil.com 1st Edition : Issued in Dec. 2007-PP 3rd Edition: Issued in Jun. 2013-AZ CP-PC-1476E (10)
Open the catalog to page 1Examples of what computation functions can do These advanced models offer the ultimate in instrumentation and control. 8 Dual-input computation capability and temperature-pressure correction are built in. Sophisticated control can be created with functions like input signal changeover, output signal changeover, and averaged value control. ■ Signal flow ■ Computation details ■ 21 computation functions Sensor input changeover Control using the average of 2 inputs Dual-input/one-output control Override control Feed-forward control, etc. • Hot start (max. setting: 32000 s) •Cold start • Hot...
Open the catalog to page 2All Azbil Europe NV catalogs and technical brochures
-
V8C/V8S
4 Pages
-
F4Q
6 Pages
-
F7M
4 Pages
-
Air purge control
2 Pages
-
Liquid temperature control
2 Pages
-
Wafer detection sensor
2 Pages
-
Wafer alignment sensor
2 Pages
-
Liquid level sensors
2 Pages
-
Liquid leakage sensors
2 Pages
-
Paperless Recorder ARF
7 Pages
-
Fiber Unit Selection Guide HPF
26 Pages
-
Gas Mass Flowmeter CMS
4 Pages
-
Air Flow Meter MCF
8 Pages
-
WET process sensors
16 Pages
-
AT9000
2 Pages
-
Digital Mass Flow Controller
6 Pages
-
High-Accuracy Position Sensors
16 Pages
-
HP series
16 Pages
-
Capacitance Diaphragm Gauge
4 Pages
-
Meets Global Standards
12 Pages
-
AX Series Vortex Meters
12 Pages
-
GasCVD
2 Pages
-
MagneW 3000 PLUS+
2 Pages
-
MagneW NeoPLUS
2 Pages
-
Single Loop Controller SDC15
2 Pages
-
Azbil Group introduction
8 Pages