video corpo

F7M
4Pages

{{requestButtons}}

Catalog excerpts

F7M - 1

MODEL SELECTION Flow Piping Base model Flow rate range Display path connection Fluid No. function material method type 1 F Optional Optional Optional Signal Connector functions functions functions type type 1 2 3 12 PARTS INCLUDED The following parts are included with the product. Mounting bracket Union nuts Sleeves Measurable flow rate range: 0.1–10 mL/min Measurable flow rate range: 0.3–30 mL/min Measurable flow rate range: 0.5–50 mL/min No display (equipped with an LED status indicator) Fused quartz glass, PFA, PTFE Fitting for fluororesin tubes SUPER-300 Type Pillar fitting P series (made by Nippon Pillar Packing Co., Ltd.) Outer dia. 3 mm, inner dia. 2 mm Fitting for fluororesin tubes SUPER-300 Type Pillar fitting P series (made by Nippon Pillar Packing Co., Ltd.) Outer dia. 1/8 in., inner dia. 0.086 in. Water (H20) Analog output, digital input, digital output Waterproof connector: HR30-6R-6P(71) None None None With inspection certificate With inspection certificate and traceability certificate Product version Model F7M Thermal Micro Flow Rate Liquid Flow Meter, achieving high-functionality measurement and usability ×1 ×2 × 2 (size depends on the model of the main unit) PARTS SOLD SEPARATELY Part Name PVC-insulated cable, 2 m Fluororesin-insulated cable, 2 m Fitting (metric system), 2 pieases Fitting (inch system), 2 pieases Mounting bracket Fluororesin tube assembly (metric system), 2 pieases Fluororesin tube assembly (inch system), 2 pieases Fluororesin tube assembly for metal pipes (female screw adaptor), 2 pieases Fluororesin tube assembly for metal pipes (male screw adaptor), 2 pieases Remarks Waterproof connector made by Hirose Electric Co., Ltd.; HR30-6P-6S(71) With sleeves and union nuts (outer dia.: 3 mm; inner dia.: 2 mm); same as included parts With sleeves and union nuts (outer dia.: 1/8 in.; inner dia.: 0.086 in.); same as included parts Same as included part Tube assembly with sleeve inserted (outer dia.: 3 mm; inner dia.: 2 mm; length: 500 mm) Tube assembly with sleeve inserted (outer dia.: 1/8 in.; inner dia.: 0.086 in.; length: 500 mm) Set including an adaptor for metal pipes and a fluoriresin tube (outer dia.: 1/8 in., tube langth : 200 mm) (adaptor : Rc 1/8 fitting, wetted material SUS316) Set including an adaptor for metal pipes and a fluoriresin tube (outer dia.: 1/8 in., tube langth : 200 mm) (adaptor : R 1/8 fitting, wetted material SUS316) Fluororesin tube assembly (φ4 mm tube) for quick-connect tube fitting, 2 pieases Set consists of a quick-connect tube fitting and a fluororesin tube Quick-connect tube fitting: for a 4 mm dia. tube (wetted material: SUS316), tube: outer dia. 1/8 in., length: 200 mm Adapter for loader communication cable Set including a cable for connecting to power supllier and a cable for flow meter main unit. USB cable for communicating with PC (81441177-00) is not included. SLP-F7M Smart Loader Package for F7M is necessary to download it from the Azbil Corporation's website and install it. https://www.azbil.com/products/factory/factory-product/flowmeter/rate-liquid/f7m/index.html USB cable for usage of Adapter for loader communication cable. Use Rev. 05 or later version of the USB loader cable. F9Y7A1 * USB cable connected with PC is needed to order separately. Please read “Terms and Conditions” from the following URL before ordering and use. https://www.azbil.com/products/factory/order.html Other product names, model numbers and company names may be trademarks of the respective company. [Notice] Specifications are subject to change without notice. No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation. Measures Flexible installation Compact, micro flow rates of and wide range of light-weight, several mL/min fluids and easy to install Yamatake Corporation changed its name to Azbil Corporation on April 1, 2012. 1-12-2 Kawana, Fujisawa Kanagawa 251-8522 Japan URL: https://www.azbil.com 1st Edition : Dec. 2017-SO 4th Edition :

Open the catalog to page 1
F7M - 2

Combining a thermal MEMS sensor with a proven track record in gas flowmeters and a flow path made of highly corrosion-resistant fused quartz glass, this product measures both the instantaneous flow rate and the totalized flow of liquids with micro flow rates of several mL/min, which has been difficult to do with a high degree of reproducibility using traditional measurement methods. Compared with conventional methods, the measurement method used by this new product is less susceptible to changes in the fluid state (e.g., bubbles, pulsations, and fluid temperature) (although it may be necessary to...

Open the catalog to page 2
F7M - 3

MEASUREMENT PRINCIPLE USEFUL FUNCTION Combining a thermal MEMS sensor that is commonly used for gas flow meters and a flow path that is made of highly corrosion-resistant quartz glass, the product uses a method of measuring micro flow rates that is less susceptible to changes in the fluid state and more reliable. Easily adjustable flow rate correction for various liquids Automatic setting of flow rate correction factor (CCF) Fused quartz glass tube Flowmeter zero point and flow rate correction factor are automatically adjusted for the liquid to be measured. Heater sensor Touch the switch Push!...

Open the catalog to page 3
F7M - 4

PRODUCT SPECIFICATIONS Measurable flow rate range (for H2O) MATERIAL OF WETTED PARTS Fluid that does not clog the flow path or damage the glass tube or corrode the wetted part materials. If any fluid adheres to the inner surface of the flow path, a measurement error may occur. In addition, if there are bubbles in the fluid or pulsation, output fluctuations or shifts may occur, depending on the amount. Measurable fluid Electrical connector port Accuracy-guaranteed fluid Measurement accuracy*1 (typical values under standard conditions)*2 ±5 % rdg (at 2 mL/min or more) ±1 % FS (at less than 2...

Open the catalog to page 4