Group: azbil
Catalog excerpts
Compact Digital Mass Flow Controller Model F4H C€ ® K (fluoro rubber seal model only)
Open the catalog to page 1A More Advanced Standard Model A new high performance standard F4H mass flow controller has now arrived! - 0.3 s high-speed controllability and 1 % SP high accuracy - Wide-range 100:1 control is now available.
Open the catalog to page 2DETAILS FOLLOW, ^ase of use ll Compact Design Saves Space Compact but equipped with the essential functions. These products help to save space. Kseof use 2 Effectively Utilize Degital Communications All models have communications functions for loT compatibility. RS-485(CPL)/ Modbus™ RTU Ease of use With isolation of the power supply from the signal circuit, power supply noise can’t affect analog signals. Additionally, highly noise-resistant 4 to 20 mA signals can be used. ^!seof use ■P Reduction in Overall Cost Overall cost is lower for reasons such as: communication functions eliminate the...
Open the catalog to page 3Compact Design Saves Space I The new products are 50 % smaller than our With a width of 28 mm, the product’s slim design conventional models. allows closer spacing of pipes, saving more space. Effectively Utilize Degital Communications RS-485 (CPL)/ Modbus™ RTU Analog mass flow controllers With model F4H's communication functions, much information can communicate only flow rate useful for fault diagnosis can be uploaded. Also, with a smart device to programmable logic controllers. gateway (model NX-SVG), the F4H can communicate with major programmable logic controllers without the need for...
Open the catalog to page 4High Noise Tolerance ® Isolation of the power supply from the signal circuit By isolating the valve drive circuit from other circuits, power supply circuit and analog circuit isolation (patent No. 5132617) is achieved, even with a small-capacity isolated power supply. Thanks to this feature, noise from power wiring has no effect on signals. © Highly noise-tolerant 4-20 mA signals can be used. Choose analog I/O signals from 0 to 5 Vdc, 1 to 5 Vdc, 4 to 20 mA. (D All models have digital communication capability Using to digital communication eliminates the effect of noise on analog signals....
Open the catalog to page 5Note: Set a flow rate within the control ranges shown above. *1 It's values when Display resolution(C-41) is high resolution.
Open the catalog to page 61.00 to 50.00 mL/min 2.0 to 200.0 mL/min 5.0 to 500.0 mL/min 0.020 to 2.000 L/min 0.050 to 5.000 L/min 0.20 to 20.00 L/min SUS316 (degreased for gas-contacting parts) UNF_ Refitting Swagelok fitting or equivalent VCR fitting or equivalent Air /Nitrogen Oxygen RS-485 CPL model RS-485 Modbus™ model_ O-ring material: fluororubber Factory setting: air/nitrogen Factory setting: oxygen None None None With an inspection report With traceability certificate Product version *1. Flow rate setting range for air, nitrogen, argon, and oxygen. For other gases, see the control flow rate range by gas type...
Open the catalog to page 7*9. During EMC testing, the reading may fluctuate by the equivalent of ±5 % FS, or the output value may fluctuate. *10. For F4H0020, C-36 (operating differential pressure) is set to “0: Low differential pressure.” *11. Use within a power supply voltage range between 23.5 and 25.2 V. *12. The maximum operating differential pressure varies according to the power supply voltage. See the following graph. The operating differential pressure range for argon is from 250 to 300 kPa. *1. mL/min and L/min are volumetric flow rate per minute (L/min) converted to conditions of 0 °C and 101.325 kPa (1...
Open the catalog to page 8‘Common to CPL and Modbus™ RTU * SG is connected to A.GND and G.GND on the connector for external connection. External Wiring Connector FLOW RATE INPUT FLOW RATE OUTPUT
Open the catalog to page 9> External Dimensions Unit: mm Mass Flow Controller on no 76 #4-40(2)-UNC Flow arrow (<- Flow direction) 1/4" Swagelok or Equivalent Fitting Type Bf ft
Open the catalog to page 10> Cautions for Flow Controllers (For installation and use of this device, refer to the warnings and cautions in the user’s manual.) - Never allow gases that are within explosive limits to pass through this device. Doing so might result in an explosion. - Never use a flow controller for oxygen gas if it is not a special oil-free oxygen gas model. Doing so could cause the gas to ignite. - Prevent foreign matter from entering the device. Rust, water droplets, oil mist, or dust from the pipes can cause measurement error, control error, or damage to the device. If there is a possibility of...
Open the catalog to page 11Smart Device Gateway Model NX-SVG Feature 1 Dramatically speeds up development with programless communication Feature2 Connect multivendor devices on the network Ethernet 1 (100 devices max.), various manufacturers' protocols Ethernet 2 (100 devices max.), various manufacturers' protocols Various Multi-loop Controller maufacuturers with Multifunction displays Display Hybrid Recorder Paperless Recorder Digital Indicating Programmable Inverter Various Controllers Controller wattmeter manufacturers' Azbil products with RS-485 communication Other company products with Modbus™ RTU ■> Mitsubishi...
Open the catalog to page 12All Azbil Europe NV catalogs and technical brochures
-
V8C/V8S
4 Pages
-
F4Q
6 Pages
-
F7M
4 Pages
-
Air purge control
2 Pages
-
Liquid temperature control
2 Pages
-
Wafer detection sensor
2 Pages
-
Wafer alignment sensor
2 Pages
-
Liquid level sensors
2 Pages
-
Liquid leakage sensors
2 Pages
-
Paperless Recorder ARF
7 Pages
-
Fiber Unit Selection Guide HPF
26 Pages
-
Gas Mass Flowmeter CMS
4 Pages
-
Air Flow Meter MCF
8 Pages
-
WET process sensors
16 Pages
-
AT9000
2 Pages
-
Digital Mass Flow Controller
6 Pages
-
High-Accuracy Position Sensors
16 Pages
-
HP series
16 Pages
-
Capacitance Diaphragm Gauge
4 Pages
-
Meets Global Standards
12 Pages
-
AX Series Vortex Meters
12 Pages
-
GasCVD
2 Pages
-
MagneW 3000 PLUS+
2 Pages
-
MagneW NeoPLUS
2 Pages
-
Single Loop Controller SDC15
2 Pages
-
Azbil Group introduction
8 Pages