Group: azbil
Catalog excerpts
AX Series Vortex Meters The readings you need, right where you need them.
Open the catalog to page 1Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in a single meter: a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer. Within this single instrument, you can measure the mass flow rates of gasses, liquids, and steam with far more accuracy than with external measurement techniques which may not adequately compensate for dynamic process conditions. With the flexibility to install in almost any location—including hot tapping—you can get precise measurements from nearly...
Open the catalog to page 2The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity. As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all welded sensor design to create a strong unit and minimize potential leakage. The AX Series can be configured to measure anything from simple...
Open the catalog to page 3Repeatability Mass Flow Rate Volumetric Flow Rate Temperature Pressure Density ±0.2% of rate ±0.1% of rate ±0.2°F (±0.1°C) ±0.05% of full scale ±0.1% of reading Pressure Transducer Ratings ±0.2% of rate ± negligible ±0.9°F (±0.5°C) ±0.1% of full scale ±0.1% of reading Mass Flow Rate Volumetric Flow Rate Temperature Pressure Density Adjustable from 1 to 100 seconds. Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel. Consult factory for other materials or construction. Not recommended for multi-phase fluids. Process and Ambient Temperature Process Standard...
Open the catalog to page 4Wafer Install Flange Install AX 2200 Flange Installation AX 2200 Wafer InstallationWeight Flow Meter Nominal Size
Open the catalog to page 5Dimensional Outline - AX 2300 Compression Installation Approximate Weight* AX 2300 Compression Installation CL/Compact Length A Compression Fitting AX 2322 Compression Installation CL/Compact Length A
Open the catalog to page 6Packing Gland - Permanent Retractor AX 2300 Packing Gland Installation Approximate Weight* Removable Retractor Permanent Retractor 'Add 11 lb (5 kg) for remote electronics. AX 2300 shown with optional permanent retractor
Open the catalog to page 7Power Requirements DCL Option: 12-36 VDC loop powered (single output) DCH Option: 12-36 VDC, 300 mA mx (multiple outputs) AC Option: 85-240 VAC, 50.60Hz, 2 Watts (multiple outputs) Display Alphanumeric 2 line x 16 character LCD digital display Six pushbuttons can be operated with magnetic wand without removal of enclosure covers Display can be mounted in 90° intervals for better viewing Output Signals Analog: 4-20 mA Alarm: Solid state relay, 40 VDC Totalizer Pulse: 50 millisecond pulse, 40 VDC Volumetric or Loop Powered Mass: One analog, one totalizer pulse, HART Multivariable option: Up...
Open the catalog to page 8Parent Mode Code In-Line Multivariable Mass Vortex Flow Meter AX2200 Volumetric Flow Meter for Liquid, Gas and Steam AX2211 Velocity and Temperature Sensors AX2222 Velocity, Temperature and Pressure Sensors AX2233 Velocity, Temperature and External Pressure Input AX2244 Energy Output Options AX2255 Energy Options with Pressure Sensor_ Feature 2: Flow Body Line Size 015 1/2-inch Nominal Bore (15mm) Feature C S H 3: Meter Body Material Carbon Steel Stainless Steel Hastelloy 4: Process Connection ANSI 150# Flange ANSI 300# Flange ANSI 600# Flange DIN PN 16 Flange DIN PN 40 Flange DIN PN 64...
Open the catalog to page 10Feature 5: Input Power 1 12-36 VDC, 25mA, 1W max, required on loop powered meters, Output Code "A" only 2 12-36 VDC, 300mA, 9W max. - use with Output Codes "B", "C", "D" and "E" 3 100-240 VAC, 50/60Hz line power, 5W max. - use with Output Codes "B", "C", "D" and "E" Feature 6: Output Options A Loop powered option - one analog output (4-20mA), one alarm, one pulse, HART (Input Power Option Code "1" only) B One analog output (4-20mA), one alarm, one pulse, HART Comm. (Input Power Option Code "2" or "3" only) C One analog output (4-20mA), one alarm, one pulse, MODBUS Comm....
Open the catalog to page 11All Azbil Europe NV catalogs and technical brochures
-
V8C/V8S
4 Pages
-
F4Q
6 Pages
-
F7M
4 Pages
-
Air purge control
2 Pages
-
Liquid temperature control
2 Pages
-
Wafer detection sensor
2 Pages
-
Wafer alignment sensor
2 Pages
-
Liquid level sensors
2 Pages
-
Liquid leakage sensors
2 Pages
-
Paperless Recorder ARF
7 Pages
-
Fiber Unit Selection Guide HPF
26 Pages
-
Gas Mass Flowmeter CMS
4 Pages
-
Air Flow Meter MCF
8 Pages
-
WET process sensors
16 Pages
-
AT9000
2 Pages
-
Digital Mass Flow Controller
6 Pages
-
High-Accuracy Position Sensors
16 Pages
-
HP series
16 Pages
-
Capacitance Diaphragm Gauge
4 Pages
-
Meets Global Standards
12 Pages
-
GasCVD
2 Pages
-
MagneW 3000 PLUS+
2 Pages
-
MagneW NeoPLUS
2 Pages
-
Single Loop Controller SDC15
2 Pages
-
Azbil Group introduction
8 Pages