1. Catalogs
  2. AXXERON HESCH electronics GmbH
  3. Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems

Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems

Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems
1 / 12 PagesView full catalog

Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems

Product catalog summary
Overview: The document discusses the HE 5750 and HE 5760 cleaning control systems designed for large industrial filter systems, particularly in waste-to-energy plants, cement works, and other industrial applications. These systems ensure compliance with strict emission regulations and optimize energy consumption.
Specifications: The HE 5750 and HE 5760 systems are master-slave configurations that connect valve control units to a main control unit via fieldbus. They are adaptable to various system sizes and can be customized for different numbers of filter chambers and valves. The systems are housed in metal wall-mounted cabinets with protection class IP54 or optionally IP65.
Key Features:
  • Plug-and-Play installation with minimal programming effort.
  • Remote monitoring and data logging capabilities.
  • Dynamic adjustment of cleaning pressure to save energy.
  • Integration of additional functions like flap control.
  • Intelligent redundancy system for maximum availability.
Energy Efficiency and Subsidies: The systems can reduce power consumption by approximately 10%, leading to significant cost savings. In Germany, a 30% subsidy is available for large industrial companies to increase energy efficiency.
Functionality: The systems include features like automatic hose rupture monitoring, dust load control, and valve function monitoring. They use a central dust sensor and volume flow signals to calculate gas velocity and monitor dust levels.
System Components: The document compares the HE 5750 and HE 5760 systems, detailing their valve outputs, control units, and additional features like damper control and dust monitoring.
Case Study: A major project in Dubai utilizes the HE 5750 system for the world's largest waste incineration plant, highlighting its integration capabilities and effectiveness in large-scale operations.
Contact Information: The document provides contact details for AXXERON HESCH electronics GmbH for further inquiries and support.
See more

Catalog excerpts

Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-1

Cleaning control systems for large industrial filter systems ENGINEERING made in Germany

 Open the catalog to page 1
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-2

Large fabric filter systems – The situation in practice Save energy with a subsidy! The use of large fabric filter systems with several hundred cleaning valves and many thousands of filter bags is used to comply with strict emission regulations, e.g. in wasteto-energy plants or cement works. This means that a high level of high functionality and continuous availability of this system must be ensured at all times. If a large filter system is not operated at 100%, there are both legal consequences if emissions are exceeded and massive costs, e.g. due to additional energy consumption. By optimising...

 Open the catalog to page 2
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-3

*Subject to legal changes. We do not guarantee the receipt of the grant. Bring your system up to date with the HE 5750 and reduce your energy consumption in the long term. The support programme of the Federal Office of Economics and Export Control (BAFA) and the German Credit Institute for Reconstruction (KfW) support large industrial companies with 30% subsidy* to increase energy efficiency. P.S. Funding only available in Germany Contact us to learn more. Calculation example: By optimising the controllers, operators of dust extraction systems can reduce the power consumption by approx. 10%,...

 Open the catalog to page 3
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-4

This is how it works! The HE 5750 and HE 5760 are master-slave systems in which the required valve control units are connected to the main control unit (master) via fieldbus according to the system size. This reduces commissioning times and costs considerably. Support is provided through remote diagnosis and maintenance via modem connection (remote access) (HE 5750). Each valve control unit is assigned to a filter chamber locally and technically. This flexible concept can be adapted to almost any desired number of filter chambers and valves. This means that the system can be customised and pre-assembled...

 Open the catalog to page 4
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-5

Process control technology Remote-PC SmartTool Local Control Damper control unit additional I/O Central shut-off valve System pressure Volume flow 4 Central dust sensor Damper controller (Up to 16 flaps, HE 5750) Pressure sensor HE 1149 Dust sensor PFM 13 C Differential pressure Tank pressure Differential pressure transmitter HE 5409 / HE 5411 / HE 5422 MR

 Open the catalog to page 5
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-6

Particularly clever – the detection of hose ruptures For this reason, the HESCH controllers in addition to comprehensive monitoring of the cleaning valve function automatic hose rupture monitoring integrated. This requires an optional central dust sensor, which is mounted to the clean gas duct at the filter outlet and controls the dust load of all chambers. If the volume flow in the filter is not varied, a constant (max.) value can also be used as a parameter. In addition, the distances between the individual filter chambers and the dust sensor must be determined once as constant parameters and...

 Open the catalog to page 6
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-7

The control unit also ensures that the individual monitoring windows do not overlap and modifies the pause between the cleaning cycles accordingly. Valve control Monitoring time window Immediate indication of the qualitative dust content during cleaning in the display If, during the monitoring phase, one of three freely defined limit values for the dust load is exceeded, the control system automatically assigns this event to the respective chamber and triggers the corresponding reaction (e.g. an error message, an alarm or a system switch off). Thus, not only is error-free operation guaranteed...

 Open the catalog to page 7
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-8

Errors and changes excepted. Further products & services can be found online

 Open the catalog to page 8
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-9

• Metal wall-mounted cabinet (IP55) MAIN CONTROL UNIT HE 5750 / HE 5760 • Central system control • Graphic display, illuminated • Ready mounted in the control box (wall mounting) • Operation with switch / indicator lights possible • Preconfigured according to customer specifications • Completely ready for connection in the switch box • Compact housing • Control cabinet installation • Power supply via the master • Valve function monitoring, tank pressure measurement • Completely connected and pre-assembled cable with valve plug available CONFIGURATION SOFTWARE SmartTool ■ Saving a main control...

 Open the catalog to page 9
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-10

Major project in Dubai with the participation of HESCH The world‘s largest waste incineration plant for energy generation will go into operation in Dubai in 2024. For cleaning the fabric filters of the 5 incineration lines, one HE 5750 is used for each line. A main control unit in the electrical cabinet, which communicates via fibre optic technology (FO) with the process control 12 slaves HE 5724, which control 13 valve rows (156 valve rows in total) One damper control for 12 dampers One dust sensor on the clean gas side 13 HE 1149 pressure sensors for recording system and tank pressure The control...

 Open the catalog to page 10
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-11

„We are delighted to participate in this flagship project for environmentally friendly energy generation with our state-of-the-art cleaning control systems

 Open the catalog to page 11
Brochure HE 5750 / HE 5760 Cleaning Control Systems for large industrial filter systems-12

Contact person Heiko Wilkens, Dipl.-Ing. More products and services from AXXERON Hesch electronics can be found on our website. Rolf Bürssner, Dipl.-Ing. (FH) +49 (0) 173 2439 388 [email protected] AXXERON HESCH electronics GmbH Headquarter Boschstraße 8 | 31535 Neustadt [email protected] T +49 (0) 5032 9535-0 Branch Nord Stöckenhoop 6 | 21465 Wentorf T +49 (0) 40 727 57-08 [email protected] ENGINEERING made in Germany

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.