1. Catalogs
  2. Axon Cable
  3. Vibraflame®, cables for extreme temperatures

Vibraflame®, cables for extreme temperatures

Vibraflame®, cables for extreme temperatures

Vibraflame®, cables for extreme temperatures

Product catalog summary
Quality Assurance
VIBRAFLAME® cables are subjected to rigorous quality control to comply with stringent international and national standards, including NBN C 30-004, which involves testing at 900°C for 3 hours with mechanical impacts and current leakage limits.
Specifications and Standards
These cables exceed various international standards such as IEC 331 and VDE 0472-814, showcasing superior performance in extreme temperatures and conditions.
Material Composition
The cables are insulated with a unique combination of mica, organic polymers, and fiberglass, providing fire resistance and thermal protection. Nickel-plated copper conductors offer resistance to high-temperature oxidation.
Applications and Benefits
VIBRAFLAME® cables are suitable for demanding environments like steel plants, oil refineries, and military installations. They maintain integrity at temperatures up to 1565°C and resist weather, chemicals, and mechanical impacts, offering cost savings and enhanced safety.
Product Range
The product range includes extension and compensating cables for thermocouples, available in various conductor materials such as Nickel alloy and Copper/Constantan.
Marking and Packaging
Cables are marked with "AXON’ VIBRAFLAME® PATENT" and can be customized. They are delivered on reels or drums with a minimum order of 50 meters.
Special Configurations
Available configurations include coaxials, triaxials, and high voltage cables, with options for armored and shielded versions for enhanced protection.
Technical Data
Specifications for single wires and multicore cables include conductor stranding, resistance, and weight, with operating voltages up to 600 V RMS and test voltages of 2200 V RMS.
Customer Buying Guide Overview
This document provides essential technical information required by the technical department to meet customer requirements. Key parameters include operating temperature, peak temperature, operating voltage, conductor section, and specific usage conditions such as mechanical constraints and atmospheric conditions.
Technical Specifications
  • Operating and peak temperatures are critical for cable selection.
  • Voltage ratings must be considered for safety and performance.
  • Conductor section size is specified in AWG or metric wire gauge.
  • Usage conditions include reeled, static, and environmental factors like heating and flame exposure.
Color Coding and Conductor Information
  • The document includes a color code chart for identifying conductors in multiconductor cables.
  • An example order code is provided for a multiconductor cable with specific insulation, braid, and armor types.
Product Types
  • Equipment Wires
  • Coaxial Cables
  • Flat Cables
  • Composite Cables
  • Harnesses
  • Special Cables
Contact Information
Contact details for AXON' CABLE offices in France, Germany, UK, USA, and Japan are provided for further inquiries and support.
See more

Catalog excerpts

Vibraflame®, cables for extreme temperatures-1

CABLES FOR EXTREME TEMPERATURES >

 Open the catalog to page 1
Vibraflame®, cables for extreme temperatures-4

CONDUCTORINSULATED WIRE CONDUCTORINSULATED WIRE AXONВSTRANDINGAREA LINEIC MAX. OUTERAPPROX.REFERENCE AXONؒSTRANDINGAREA LINEIC MAX .OUTERAPPROX.REFERENCE RESISTANCE ؘWEIGHT RESISTANCE WEIGHT mmmm > 2 آĦ /100mmmg/m mmmm > 2 Ω /100mmmg/m > (*) M : according to MIL specification - N : according to NF specification >

 Open the catalog to page 4
Vibraflame®, cables for extreme temperatures-5

MULTICORESHIELDED SIGNALSIZE CROSSNUMBER OF WIRESCABLES REF.CABLES REF.SECTION/AWGmin.max. BV 2607 V xBV 2607 ST V xAWG 26225BV 2407 V xBV 2407 ST V xAWG 24224 BV 2207 V xBV 2207 ST V xAWG 22221 BV 0.50 V xBV 0.50 ST V x0.50 mm > Type BVΕ Jacket : VIBRAFLAME > 2 212 > BV 2019 V xBV 2019 ST V xAWG 20212 BV 0.75 V xBV 0.75 ST V x0.75 mm > 2 212 BV 1.00 V xBV 1.00 ST V x1.00 mm > 2 212BV 1819 V xBV 1819 ST V xAWG 18212 BV 1619 M V x*BV 1619 M ST V x*AWG 16212 BV 1619 N V x*BV 1619 N ST V x*AWG 16212 BV 1.50 V xBV 1.50 ST V x1.50 mm > 2 212BV 1419 V xBV 1419 ST V xAWG 1429 Shielded signal cables...

 Open the catalog to page 5
Vibraflame®, cables for extreme temperatures-6

MULTICORESHIELDED SIGNALSIZE CROSSNUMBER OF WIRESCABLES REF.CABLES REF.SECTION/AWGmin.max. RV 2607 V xRV 2607 ST V xAWG 26219RV 2407 V xRV 2407 ST V xAWG 24219 RV 2207 V xRV 2207 ST V xAWG 22219 RV 0.50 V xRV 0.50 ST V x0.50 mm > Type RVΕ Jacket : VIBRAFLAME > 2 212 > RV 2019 V xRV 2019 ST V xAWG 20212 RV 0.75 V xRV 0.75 ST V x0.75 mm > 2 212 RV 1.00 V xRV 1.00 ST V x1.00 mm > 2 212RV 1819 V xRV 1819 ST V xAWG 18212 RV 1619 M V x*RV 1619 M ST V x*AWG 16212 RV 1619 N V x*RV 1619 N ST V x*AWG 16212 RV 1.50 V xRV 1.50 ST V x1.50 mm > 2 212RV 1419 V xRV 1419 ST V xAWG 1427 Shielded signal cables...

 Open the catalog to page 6
Vibraflame®, cables for extreme temperatures-8

AXON' KABEL GmbH POSTFACH 1131 D - 71201 LEONBERGHERTICHSTR. 10 D - 71229 LEONBERG TEL. : +49 7152-97992-0 - FAX : +49 7152-97992-7 VIDEOCONF. : +49 7152-97992-6 e-mail : [email protected] > AXON' CABLE Ltd RIDGE WAY - DONIBRISTLE INDUSTRIAL PARKHILLEND - DUNFERMLINE - FIFE KY11 9JN - UKTEL. : +44 1383-821081 - FAX : +44 1383-821080 VIDEOCONF. : +44 1383-820727 e-mail : [email protected] > AXON' CABLE INC. 1601 FEEHANVILLE DRIVE - SUITE 600MOUNT PROSPECT - IL 60056 - USATEL. : +1 847 699-8822 - FAX : +1 847 699-8966 VIDEOCONF. : +1 847 827-5550 e-mail : [email protected] - http://www.axoncable.com...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.