Battery Charger Mode AC/DC Power Supply Mode CAN bus (SAE J1939) High Efficiency with Axiomatic Electronic Assistant • Charges a 12V or 24V lead-acid battery as well as other battery chemistries • Maximum output power of 350 W (14V / 25A) in Model AX090550 • Maximum output power of 405W (27V / 15A) in Model AX090560 • Power supply mode: 95-260VAC/5-24Vdc, up to 15A • Designed for mounting in a vehicle or in a stationary engine • Managed heat dissipation so no fan cooling is required • Wide ranging operation from 95 to 260 VAC, 45/65 Hz • Highly efficiency design (90%) • Inherent power factor correction • Microprocessor controlled (standard control logic) • Application-specific charging profiles for OEMs available • Battery charging without operator involvement • Configurable for battery optimization • Monitors a remote battery temperature sensor for safe operation and prevention of battery overheating • Transmits charger condition, line connection status, battery voltage, and charge current over CAN bus • Four relays to connect to independent alarms for AC fail, charger fail, low battery volts, and high battery volts or for other uses • Error mode shutdown • Precharge, Bulk Charge, and Constant Voltage charge modes. Equalization is available as needed. • Automatic retain charge in Float mode • Permits load connection to battery (after fully charged) with Float Mode enabled • Software overvoltage protection can be activated to ensure load safety if it cannot tolerate 31Vpeak output • The Axiomatic Electronic Assistant configures the charger to suit the application. • Operational from -40 to 70°C (-40 to 158°F) for input >170VAC • Corrosion resistant packaging, IP67 rated for harsh environments, vibration compliant • Add on module options: CAN to Ethernet Converter; CAN to Modbus RTU Converter; CAN to Bluetooth Converter • Off-highway Vehicles, Lift Equipment, Electric Vehicles, Fleet and Utility Vehicles, Emergency Vehicles • Power Gensets, Oil and Gas Equipment, Electric Utility Substation Switchgear Axiomatic Technologies Corporation 1445 Courtneypark Dr. E. Mississauga, ON Canada L5T 2E3 Tel. 1 905 602 9270 [email protected]
Open the catalog to page 1Battery Charger, 12V, 25A model: AX090550 Battery Charger, 12V/24V, 15A model: AX090560 DC Power Supply, 12V/25A model: AX090550-04 DC Power Supply, 12V/15A model: AX090560-04 DC Power Supply, 24V/15A model: AX090560-05 Contact Axiomatic for other requirements. Axiomatic Electronic Assistant Configuration KIT, P/Ns: AX070502, or AX070506K Mating Plug kits: Mating receptacle assemblies can be ordered from a Molex supplier. COMMUNICATION OPTIONS: Optional CAN/Bluetooth Converter: AX141150 Optional CAN/CAN/Modbus RTU Converter: AX140100 Optional CAN/Ethernet Converter: AX140900 Optional 1 Analog...
Open the catalog to page 2Electrical Connections 1 4-pin Molex 194280006 (Mates with Molex 194180004 Receptacle) When in AC/DC power supply mode, connect as follows. This product supports one battery output. The 2 pins for Batt+ and 2 pins for Batt-are used to share the current through them. For example, a 10A system will work with Pin 1 and Pin 2 connected but it is recommended to connect all 4 pins (Pins 1&4 joined together to Batt+ and Pins 2&5 to Batt-). Mating Connectors: Mounting_ Mating receptacle assemblies can be ordered from a Molex supplier. Use 6 M8 or #4 bolts to mount the device.
Open the catalog to page 4The Battery Charger implements a three-stage charging algorithm, as shown below in Figure 2. The charging process starts from Precharge Stage, then, when the battery voltage reaches a certain point, it switches to the Bulk Charge Stage. Next, the charging process is finalized in the Absorption (Constant Voltage) Stage. The charger can then maintain the battery charge in Float Stage. When the charger is disconnected from the power line, it automatically switches off within one minute by default. This protects the battery from being discharged by the charger electronics. Each stage of the charging...
Open the catalog to page 7Ieq Ipc Icv_stop Ifl_stop Vfl Vpc_start Vfl_start Vcv_start Fig.3. Voltage-Current Charging Profile Constant Voltage Mode In Constant Voltage Mode the output voltage of the charger is limited to Vcv and the output current – to Ibc. Once the battery voltage reaches Vcv, the charger is not able to maintain the Ibc constant charging current, so the current gradually drops to Icv_stop and the battery is considered fully charged. Constant Voltage Mode is usually the last charging mode in the charging process. At the end of this mode the charger switches to either Standby or Equalize Mode. Equalize...
Open the catalog to page 8I | - Charging with Constant Current | | - Charging with Constant Voltage and Li^aited Current
Open the catalog to page 95 Pages