The ZHM series positive displacement flow meters are designed for measuring multi-viscosity fluids. Made from stainless steel and tungsten carbide, they are suitable for abrasive and high-pressure fluids. The meter measures liquid volume as each gear tooth passes the sensor, ensuring no fluid slippage even at low flow rates, thanks to precise manufacturing tolerances.
| Model | GPM Range | Impulses/Gallon | Pressure Rating (PSI) | Weight (lb) |
|---|---|---|---|---|
| ZHM-01 | 0.001 - 0.25 | 155,000 | 9,000 | 3 |
| ZHM-01/1 | 0.003 - 0.5 | 100,300 | 9,000 | 3 |
| ZHM-02/1 | 0.01 - 0.5 | 31,000 | 9,000 | 5 |
| ZHM-02 | 0.02 - 2.0 | 15,900 | 9,000 | 5 |
| ZHM-03 | 0.1 - 7 | 6,600 | 9,000 | 6 |
| ZHM-04 | 0.1 - 20 | 1,800 | 8,000 | 20 |
| ZHM-05 | 1.0 - 40 | 500 | 6,000 | 50 |
| ZHM-06/1KL | 1.0 - 66 | 400 | 6,000 | 70 |
| ZHM-06KL | 5 -132 | 200 | 6,000 | 70 |
| ZHM-07KL | 13 -265 | 90 | 6,000 | 114 |
Rev. 05/12 ZHM Series Positive Displacement Flow Meter Technical Specifications: · Flow ranges 0.001 to 265 GPM · Accuracy ± 0.5% of reading · Pressure rating up to 9000 PSI · Great for multi-viscosity fluids · 303 SS or 316Ti bodies · Long operating life What is a ZHM Meter? The ZHM series positive displacement flow meters are ideally suited for multi-viscosity fluid measurement. Manufactured of stainless steel and tungsten carbide, the ZHM meter can be used with abrasive fluids as well as those fluids under high pressure. The ZHM measures a small volume of liquid as each gear tooth passes the sensor. The uncompromised manufacturing tolerances prevents slippage of fluid even at the lowest flow while the robust design ensures a long operating life. 8809 Industrial Drive, Franksville, WI 53126 Phone: (262) 884-9800 Fax: (262) 884-9810 Email: [email protected] www.awflowmeters.com
Open the catalog to page 1Rev. 05/12 ZHM Series Positive Displacement Flow Meter Meter Technical Data Materials of Construction: Body: Stainless Steel Gear: Stainless Steel O-Ring: PTFE standard / FKM optional Bearings: Tungsten Carbide Accuracy: ± 0.5% of actual reading Repeatability: ± 0.1% Temperature: max 180° C / 350° F Filtration: Not Provided - See recommendation Impulses / Impulses Gallon / CC Pressure Weight Rating ( (lb) PSI A in B in C Adaptor Pb Filtration (Micron) 41.00 2.90 1.61 M12 x 1.5 1/4” NPT 120 9,000 3 100,300 26.50 2.99 1.61 M12 x 1.5 1/4” NPT 120 9,000 3 0.01 - 0.5 31,000 8.80 3.33 2.00 M12 x 1.5...
Open the catalog to page 22 Pages
37 Pages