MX 9000

MX 9000

MX 9000

Product catalog summary
Overview: The MX 9000 Process Monitor is designed for industrial flow measurement applications requiring a compact and easy-to-use remote flow monitor. It offers various functionalities including rate, total, limit, batch, and ratio monitoring.
Features:
  • Options for rate, total, limit, batch, and ratio monitoring.
  • Single or dual channel capabilities.
  • Two programmable Form C relay outputs (optional).
  • Assignable 4-20 mA output (optional).
  • LCD display with color backlight for warnings or alarms.
  • Batch controller capable of storing up to 20 batch recipes.
Applications: The MX 9000 is versatile, allowing for monitoring of single or dual flows, displaying them separately, as a sum, difference, or ratio. It can also detect bi-directional flow when signals from a single flow meter are available.
Benefits:
  • Monitoring versatility with one or two channels for flow rate and volume.
  • Customizable housing options to meet specific application requirements.
Technical Specifications:
  • Power Requirement: 14 to 16 VAC/250mA, 18-24 VDC/200mA, or 120/240 VAC (optional).
  • Flow Sensor Power Supplies: Two at 15 VDC/up to 50 mA each.
  • Frequency Inputs: 0-4 KHz, with a minimum amplitude of 4 volts.
  • 4-20 mA Analog Output: External-powered loop output into a maximum 500 ohm load impedance.
  • Integrated Linearization: 30-point linearization table for improved accuracy.
Installation and Programming: The MX 9000 offers easy remote programming and quick setup, allowing for operation within minutes.
Contact Information: For more information, contact AW Gear Meters at 800-850-6110 or visit www.awgearmeters.com.
Part Number Guide: The guide provides options for output, communication, main board, and option boards, allowing customization based on specific needs.
See more

Catalog excerpts

MX 9000-1

MX 9000 Process Monitor Ideal for any industrial flow measurement application where a simple, compact & easy-to-use remote flow monitor is required. Features: • Rate, total, limit, batch and ratio options • Single or dual channel • Two programmable Form C relay outputs (optional) • One or two assignable 4-20 mA output (optional) • Easy-to-read LCD display with color backlight that changes color for warning or alarm • Batch controller - stores up to 20 batch recipes Applications: The MX 9000 Process Monitor is a versatile, multi-functional device that helps you track rate, total, limit, ratio, and more. Standard unit is one channel. Optional two channels allow you to monitor dual flows, and display them in a number of ways: separately, as a sum (for example in total material use), as a difference (as in fuel consumption), or as a ratio of product A/product B. Also use the MX 9000 to detect bi-directional flow when A and B channel signals are available from a single flow meter. The MX 9000 has a number of related functions that add to its capabilities. Four model variations (see reverse side) give the MX 9000 the capability of performing limit, warning and alarm duties. Benefits: MONITORING VERSATILITY The MX 9000 is available with one or two channels, to monitor: • Flow rate from one or two meters • Flow volume (sum or difference of two flows) • Ratio (product A/product B) CUSTOMIZABLE HOUSING OPTIONS The MX 9000 is available in custom enclosures to meet your application requirements. Technical Specifications: • Power Requirement: 14 to 16 VAC/250mA, or 18-24 VDC/200mA (customer supplied), or 120/240 VAC (optional). *All units are shipped with 120VAC/1000mA wall transformer. • Flow Sensor Power Supplies: (2) @ 15 VDC / up to 50 mA each • Frequency Inputs: 0-4 KHz, sine, square or saw-tooth; 4 volts minimum amplitude; 3.3 Kohm maximum impedance • 4-20 mA Analog Output: External-powered loop output into a maximum 500 ohm load impedance with 24 VDC supply. 2nd loop output optional. • Integrated Linearization: Maximum 30-point linearization table for improved accuracy over range. EASY REMOTE PROGRAMMING This unit can be easily programmed to display what you need in a variety of engineering units. UP AND RUNNING IN MINUTES Easy plug-in installation. A quick setup procedure allows you to have the flow monitor working with just a few simple programming steps. © 2013 AW-Lake Company All rights reserved.

 Open the catalog to page 1
MX 9000-2

MX 9000 Process Monitor Terminal Assignments: Upper Connector Option Board Dependent Option board Main board Monitor Dimensions: Lower Connector +18-24VDC/16VAC DC COM/16VAC +15VDC Out Sig. 1 In Sig. 1 Common +15VDC Out Sig. 2 In Sig. 2 Common EXT Reset + EXT Reset I + Out 1 I - Out 2 Part Number Guide: MX 9 – – Main Board: S = Single channel flow/total D = Dual channel flow/total R = Ratio monitor B = Batch controller Output: 4 = 4-20mA output X = No output Option board Option board Main board Main board Products may be subject to change without notice Contact factory for the most up-to-date...

 Open the catalog to page 2

All AW-Lake Company catalogs and technical brochures

  1. Printing Ink

    1  Page

  2. OILandGAS

    2  Pages

  3. Proscan

    1  Page

  4. RT 30 EX

    2  Pages

  5. RT-10

    2  Pages

  6. LLC-BA

    2  Pages

  7. JVK

    2  Pages

  8. ZHM

    2  Pages

  9. SRZ hires

    2  Pages

  10. SRZ

    2  Pages

  11. JVM

    2  Pages

  12. LLC BA

    2  Pages

  13. Brochure 2011

    4  Pages

  14. JVHS

    2  Pages

  15. JV-KG

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.