Spectrometers AvaSpec-ULS2048XL-EVO SensLine High UV and NIR Sensitivity Back-thinned CCD Spectrometer AvaSpec-ULS2048XL-EVO Optical Bench Wavelength range Resolution Stray-light Sensitivity UV Quantum efficiency Detector Signal/Noise AD converter Integration time Sample speed with store to RAM Readout Noise Dark Noise Dynamic Range Data transfer speed Power supply Dimensions, weight Combining exceptional quantum efficiency with high-speed is the value proposition of the AvaSpec-ULS2048XL-EVO spectrometer. Unlike many back-thinned CCD spectrometers, which have two dimensional arrays, the ULS2048XL-EVO has large monolithic pixels of 14x500 microns with exceptional efficiency in the UV, from 200-400 nm, and the NIR, from 950-1160 nm. The instrument also has an electronic shutter, which enables integration times as low as 2 microseconds. To further enhance sensitivity, a detector collection lens is available which improves sensitivity up to 60% when combined with larger core fibers. Options include order-sorting filter, to reduce 2nd order effects and purge ports for deep-UV measurements. The AvaSpec-ULS2048XL-EVO comes with a wide range of slit sizes, gratings and may be configured with SMA or FC/PC fiber-optic entrance connectors. The AvaSpec-ULS2048XL-EVO uses the AS7010 electronics board offering USB3 (10 times faster than USB2), Gigabit Ethernet and better signal processing. Connection to your PC is handled via a USB3-connection or Ethernet, delivering a scan every 2 milliseconds. The instrument comes complete with AvaSoft-basic software, USB cable and an extensive manual. Technical Data ULS, Symmetrical Czerny-Turner, 75 mm focal length 200 - 1160 nm 0.09 -20 nm, depending on configuration (see table) Back-thinned CCD image sensor 2048 pixels 525:1 USB 3.0 high-speed, 5 Gbps Gigabit Ethernet 1 Gbps HD-26 connector, 2 Analog in, 2 Analog out, 3 Digital in, 12 Digital out, trigger, synchronization Default USB power, 700 mA. Or external 12VDC, 360 mA 175 x 127 x 44,5 mm (1 channel), 1180 grams aVKntes | [email protected] | www.avantes.com member of the nynomic group
Open the catalog to page 1Grating Selection Table for AvaSpec-ULS2048XL-EVO Use Order code * depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the smaller the range to select. ** please note that not all 2048 pixels will be used for the useable range Resolution Table (FWHM in nm) for AvaSpec-ULS2048XLEVO Slit size (µm) Grating (lines/mm) * depends on the starting wavelength of the grating; the higher the wavelength, the bigger the dispersion and the better the resolution • Ultra-low Stray-light Fiber-optic Spectrometer, 75 mm AvaBench, 2048 large 500 µm pixel back-thinned...
Open the catalog to page 2Options -RS DCL-UV/VIS-200 SLIT-XX SLIT-XX-RS SLIT-XX-RS-FCPC OSF-YYY OSC • Replaceable slit • Quartz Detector Collection Lens (200-1100 nm) • Slit size, please specify XX = 10, 25, 50, 100, 200 or 500 µm • Replaceable slit with SMA connector , specify slit size XX=25, 50, 100, 200 or 500 µm. Only in combination with AvaSpec-ULS2048XL-EVO-RS • as SLIT-XX-RS, but with FC/PC connector • Order-sorting filter for reduction of 2nd order effects, 1 mm thick, please specify YYY= 305, 395, 475, 515, 550 or 600 nm • Order-sorting coating with 600 nm long-pass filter for BB (>350 nm) and VB gratings, recommended...
Open the catalog to page 38 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
53 Pages
2 Pages
8 Pages
2 Pages