Indoor Air Quality Transmitter AVC-M Series In most public space or office buildings, the air ventilation and air quality is poor. The AVC-M series can detect several important parameters of indoor air quality and environment, such as CO2, CO, HCHO, O2, NH3, TVOC, PM2.5, PM10, temperature and humidity. Easy installation and the recommended height of installation is 1~2M above the floor level. It uses good quality sensors; such as the NDIR CO2 sensor; electro-chemical sensor for HCHO, CO, O2 and NH3; laser scattering principle sensor for PM2.5 and PM10; CMOS sensor for TVOC, temperature and humidity. AVC-M can be used with a monitoring system, which can activate ventilation system to keep a better indoor air quality or for energy saving. It is perfect for school, library, offices, meeting room, commercial building, shopping center, train/subway station or exhibition hall, etc.

Open the catalog to page 1
Aecl Indoor Air Quality Transmitter (AVC-M, CO2, CO, HCHO, O2, NH3, TVOC, PM2.5, PM10, RH, Temperature) - 2

General technical data Parameters Signal output Temperature, Humidity, CO2, CO, HCHO, TVOC, PM2.5, PM10, O2, NH3 RS485 or RS485 / LoRa (Peer to Peer) switchable, LoRa frequency band: 862 ~ 932 MHz(1) Warm-up time Operating environment Storage temperature Power supply Power consumption IP30 (No protection from liquids) Case material Temperature Measurement Humidity Measurement Sensing element CMOS sensing element CMOS sensing element Measurement range Response time Long-term drift Measurement principle NDIR with automatic calibration CMOS sensing element Measurement range Response time

Open the catalog to page 2
Aecl Indoor Air Quality Transmitter (AVC-M, CO2, CO, HCHO, O2, NH3, TVOC, PM2.5, PM10, RH, Temperature) - 3

HCHO Measurement Measurement principle Measurement range Response time Span: ≦5% reading /year Span: < 20% reading /year Measurement principle Laser distributing Laser distributing Measurement range Response time Maintenance-free for normal indoor Maintenance-free for normal indoor Measurement principle Measurement range Response time Zero:< ±10 ppm /year; Span: < 2% reading /month Note 1: In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation with ABC. However, some industrial applications do require maintenance. Note 2: Accuracy is specified at room...

Open the catalog to page 3
Aecl Indoor Air Quality Transmitter (AVC-M, CO2, CO, HCHO, O2, NH3, TVOC, PM2.5, PM10, RH, Temperature) - 4

AVC-M□□□□□□-M Code 1 Gas type Wall mount Code 5 Signal output 4 **All information is subject to change without prio