Overview: The AVC-31X series is designed for detecting carbon dioxide (CO2), temperature, and humidity in indoor environments. It is available in wall-mounted and duct-mounted configurations, suitable for intelligent ventilation and environmental monitoring systems in buildings.
Specifications: The series includes two models: AVC-310 (CO2 only) and AVC-311 (CO2, temperature, and humidity). The devices use NDIR infrared waveguide technology for CO2 detection, ensuring high accuracy. They operate within a temperature range of -10 to 50°C and humidity range of 0 to 95% RH. The CO2 detection range is 0 to 9999 ppm.
Installation: Wall-mounted units should be installed 1 to 2 meters above the ground, while duct-mounted units are placed within air ducts. The devices are suitable for areas up to 100m², with specific installation recommendations based on room layout.
Performance: The devices offer a CO2 response time of less than 10 seconds at a 30 cc/min flow rate. Temperature and humidity sensors provide rapid response times and high accuracy. The devices feature automatic baseline correction for CO2, ensuring minimal zero drift over time.
Power and Connectivity: Power options include DC 12-36V and AC 24V. Signal outputs are available in various formats, including 0-20mA, 4-20mA, 0-10V, and RS485/LoRa. The devices consume a maximum of 2.4W.
Certifications and Materials: The devices are CE and FCC certified, with housings made from fireproof ABS. Wall-mounted units have an IP30 protection rating, while duct-mounted units are rated IP65.
Recommendations: For optimal performance, continuous operation for three weeks is recommended to achieve full accuracy. Special applications may require additional calibration or maintenance.
See more

Catalog excerpts

Aecl CO2 Transmitter (CO2 sensor, For High Humidity, Separated)-1

CO2 Transmitter CO2, Temperature & Humidity Transmitter AVC-31X Series AVC-31X series is specially designed to detect carbon dioxide, temperature and humidity in indoor environment. The installation method can be divided into wall-mounted type and duct type. The duct type can be installed in the air duct of the air-conditioning system, and the installation height of the wall-mounted type is recommended to be between 1 and 2 meters above the ground. It can be applied to intelligent ventilation system control and environmental monitoring. It can be used with the ventilation system and air conditioning system of intelligent buildings to perform appropriate ventilation control according to the number of people in the room, control energy consumption and improve indoor air quality. The detection method adopts NDIR's infrared waveguide technology and air sampling sensing components, which improves the accuracy of its measurement. It is mostly used in shopping malls, offices, conference rooms, classrooms, restaurants, railway stations or various public places; other high-concentration models with a detection range of up to 9999ppm can be used in wine cellars, breweries, Chemical gas plants, etc. Side view of duct-mount type

 Open the catalog to page 1
Aecl CO2 Transmitter (CO2 sensor, For High Humidity, Separated)-2

CO2, Temperature & Humidity Transmitter Coverage area Alarm output Relay output N.O,N.C ( 2A / 30V DC ; 0.5A / 125V AC) Pressure dependence Operating conditions Storage temperature Warm-up time ≤ 1 min. (at full specs ≤ 15 minutes) Power supply Sampling interval Power consumption Case material

 Open the catalog to page 2
Aecl CO2 Transmitter (CO2 sensor, For High Humidity, Separated)-3

CO2, Temperature & Humidity Transmitter Gold-plated infrared (NDIR) waveguide technology with Automatic technology with Automatic Baseline Correction (ABC) and passive gas diffusion passive gas diffusion (no moving Sensing element Gold-plated infrared (NDIR) wave-guide Response time Temperature & humidity:CMOS sensor CO2: < 10 sec. @ 30 cc/min. flow rate < 3 min. diffusion time CO2: < 10 sec. @ 30 cc/min. flow rate < 3 min. diffusion time Temperature:min. 3 sec.;max. 30 sec. at τ63% Humidity:< 8 sec. at τ63% <±10ppm/yr. with Automatic Baseline Zero Drift <±10 ppm/yr. with Automatic Baseline Correction...

 Open the catalog to page 3
Aecl CO2 Transmitter (CO2 sensor, For High Humidity, Separated)-4

Note 1:For general indoor air quality monitoring application, the accuracy can be achieved after three-week continuous measurement, because of ABC function. However, in some industrial applications, maintenance or calibration may be required. Note 2:The accuracy is determined under temperature at 25℃ and barometric pressure at 101.3kPa, with comparison to the calibrated gas, of which the uncertainty (±1%) is considered. The AVC-31x series is for general indoor use. For any special application, such as industrial or agriculture, please contact us. (1) The frequency channels will be differed by...

 Open the catalog to page 4

All Autotronic Enterprise Co., Ltd. (Aecl) catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.