video corpo cad

LE7M-2
12Pages

{{requestButtons}}

Catalog excerpts

LE7M-2 - 1

0 Features • Easy to check and change the program setting • Customizable weekly or yearly unit time setting and control by user • Includes daylight saving time function • Built-in 2 independent control output (relay) • Flush and surface mounting are in one unit • Enable to mount on DIN rail with base plate A Please read “Caution for your safety” in operation manual before using. ^Environment resistance is rated at no freezing or condensation.

Open the catalog to page 1
LE7M-2 - 2

Weekly/Yearly Timer RESISTIVE LOAD 0 Load Connection You must connect a surge absorber to the both ends of the load to prevent from damage or malfunction of this unit when controlling non-resistive load (ex: magnetic switch, etc). • In case of controlling the load directly Power circuit for load operation Magnetic Switch -o-

Open the catalog to page 2
LE7M-2 - 3

1) Front panel mounting ● Panel hole cut-out Base plate How To Switch From The Flush Mounting To Surface Mounting Type Remove terminals from the body after unscrewing terminal screws, and then assemble terminals to the body after rotating terminals as shown below. ① Unscrew 4 bolts from terminal block. (Front panel mounting) (Surface mounting) ② Detach terminal block from case and then rotate it 180 degree. ③ Assemble terminal block to case by using the

Open the catalog to page 3
LE7M-2 - 4

Weekly/Yearly Timer 1. Day indicator 2. Day display • Light: Day is selected. • Light-out: Day is not selected. 3. Current time setting mode indicator 4. DST display (Daylight saving time) 5. AM/PM display 6. Season display 7. Program display 8. Display ON time/day, OFF time/day, ON time width, OFF time width 9. AM/PM display 10. YEAR display : It turns ON when set, check, modify, delete yearly program, set yearly holidays and operate yearly program. 11. Yearly START/STOP day display 12. Main display 13. Remaining step display 14. Operation mode display 15. Power restore input display 16....

Open the catalog to page 4
LE7M-2 - 5

• Set range for ON/OFF time width : 1min. to 12 hour 59min. • One record in 3 steps (ON day/ON time, OFF day/OFF time, ON time width/OFF time width) OFF width <0 Display and change of next mode • The day of next mode in Program 1 or Program 2 is displayed on the day indicator, and the time of next mode is displayed on the lower row of screen. Press |SET| + CHECK in RUN mode it is changed from program 1 to program 2 or from program 2 to program 1. • In ON/OFF operation mode, set ON time and OFF time to next mode. In Pulse operation mode, set Pulse ON time to next mode. © Power restore mode...

Open the catalog to page 5
LE7M-2 - 6

Weekly/Yearly Timer Weekly/Yearly Timer © Daylight saving time To utilize daylight during the summer season, daylight saving time is adjusted forward one hour from standard time. In setting group 2-LEVEL 2 (d5t turns ON, At or nor flashes.), select Auto [At ] or Normal [nor] by ® or [▼] key and press |SET| key to set. • Auto[At ] Daylight Saving Time mode Current time will be faster as an hour when it is started and slower as an hour when it is finished. • Automatic Daylight Saving Time period setting © Automatic Daylight Saving Time period setting LEVEL 1 of setting group 2. (d5t flashes...

Open the catalog to page 6
LE7M-2 - 7

LE7M-2 Program Setting Setting group 1 Setting group 2 RUN mode RUN mode Press MODE key for 3sec. Program 1 weekly programsetting mode (PROG P1 flashes) MODE Program 2 weekly programsetting mode (PROG P2 flashes) MODE Program 1 weekly program delete mode (PROG P1, CLR flash) MODE Program 1 weekly program delete mode (PROG P2, CLR flash) MODE Program 2 yearly program delete mode (PROG P2, YEAR, CLR flash) MODE Program 1 weekly program setting Program 2 weekly program setting Program 1 yearly program setting Program 2 yearly program setting LEVEL2 Power failure return selection mode (RET...

Open the catalog to page 7
LE7M-2 - 8

Weekly/Yearly Timer ⑦ OFF time setting (AM, PM) Weekly program setting ● eekly ON/OFF mode W (E.g.) Output 1 (OUT1) is ON from Monday to Friday at 8:00 AM and OFF at 6:10 PM. SUN ① Advance to program 1 (P1) weekly program setting mode Select PM by or key and move the flashing to hour position by key. (B) Fiber Optic Sensors (C) Door/Area Sensors ⑧ OFF time setting (Hour, Min.) Move the flashing to minute position after set 6:00 by or key and set the minute as 10 and press SET key. key is pressed over 3sec. in RUN mode, PROG P1 flashes and press SET key. MODE (E) Pressure Sensors (F) Rotary...

Open the catalog to page 8
LE7M-2 - 9

Press key to move the indicator to Monday, it will be lighted when or key is pressed and move it to Tuesday by key. Press SET key after light Tuesday, Wednesday, Thursday and Friday. Press key, move the flashing to hour position and select PM by or ● Weekly cycle mode (E.g.) utput 1 (OUT1) is ON for 10min and OFF for 5min O from monday 6:00AM to saturday 5:30PM. SAT SUN 6:00 AM Start Cycle mode ① Advance to program 1 (P1) weekly program setting mode SUN MON TUE WED THU FRI SAT In RUN mode, press MODE key for 3 sec. and PROG P1 flashes. Press SET key. ⑥ ON time setting (Hour, Min.) SUN MON...

Open the catalog to page 9
LE7M-2 - 10

Weekly/Yearly Timer Weekly/Yearly Timer © Weekly day change It operates when the specified day mode is required to install in other day from the set day and it returns to previous program setting automatically when it is finished. It is applied to program 1 (P1) and program 2 (P2). • Weekly day change cancellation © Change current year, month, date in current time setting mode © Change standard day © Delete all program in program 1 (P1) and program 2 (P2) © Season switching • Setting example Output 1 (OUT1) is ON in Saturday at 9:00AM and OFF at 12:00PM and it is ON 8:30AM and OFF at 6:00PM...

Open the catalog to page 10
LE7M-2 - 11

© Yearly program setting • Yearly ON/OFF mode (E.g.) Output 1 (OUT1) is ON from every 5, Apr to 7, Apr at 9:00AM and OFF 5:10PM. © Advance to program 1 (P1) yearly program setting mode SUN MON TUE WED THU FRI SAT Press ImodeI key for 3sec. in RUN mode, PROG P1 is flashed and press ImodeI key 3 times more until PROG P2 YEAR flashes and press I set I key. © Mode type setting SUN MON TUE WED THU FRI SAT Press I set I key when ON/ OFF flashes. © OFF time setting (Hour, Minute) © Complete to set SUN MON TUE WED THU FRI SAT Press I set I key to set additional program. • Yearly pulse mode...

Open the catalog to page 11

All Autonics catalogs and technical brochures

  1. BS5 series

    4 Pages

  2. BH series

    7 Pages

  3. MST series

    2 Pages

  4. BTS series

    7 Pages

  5. BC Series

    7 Pages

  6. PR series

    10 Pages

  7. SP Series

    4 Pages

  8. PT series

    4 Pages

  9. PRA Series

    4 Pages

  10. AS series

    2 Pages

  11. PR series

    6 Pages