Introduction
The document introduces the Takt Time Controller by Automax, a pioneering actuator controller designed for enhanced automation in production lines. It supports up to 16 units via daisy chain connection and is compatible with the iB-Flow main unit, offering automatic monitoring and correction of cylinder takt time.
Specifications
The controller allows continuous operation of air cylinders at a set takt time, reducing manual adjustments. It features digital settings for needle opening from 0 to 100% and is compatible with various GCD models. The transition from analog to digital settings enhances accuracy.
Procedures
The device monitors cylinder operations, making automatic corrections to maintain takt time using ON/OFF signals from sensor switches. It is set up via a setting device connected to the iB-Flow main unit, allowing precise adjustments and synchronization.
Norms and Recommendations
Optimal performance is achieved using support software compatible with Windows and requiring Microsoft .NET Framework 4. The device includes a safe lock mechanism to prevent needle loosening and operates without continuous power supply.
Applications
The controller is suitable for precision flow adjustment in various applications, including vacuum breaking and ionizer operation. It supports predictive maintenance by monitoring cylinder takt time variations.
Conclusion
The Takt Time Controller enhances production line automation with real-time monitoring, automatic corrections, and improved maintenance capabilities. Its digital settings and compatibility with multiple units improve productivity and reduce maintenance efforts.
Overview
The document details technical specifications, safety precautions, and handling instructions for the iB-Flow main unit and related products, emphasizing adherence to safety standards to prevent injury and equipment damage.
Specifications and Features
  • Automatic takt time adjustment via the setting device's copy function for efficient configuration across machines.
  • Designed for general industrial machinery, not for medical or critical safety applications.
Safety Precautions
  • Compliance with ISO4414 and JIS B 8370 safety standards is mandatory.
  • Avoid use near flammable substances or in explosive environments.
  • Modifications or inappropriate disassembly are prohibited due to risks of injury or fire.
  • Warnings for users with pacemakers due to strong magnetic fields.
Handling and Maintenance
  • Use genuine AUTOMAX parts for maintenance and repairs.
  • Ensure proper mounting and support to prevent accidents.
  • Regular inspections are necessary for system functionality and safety.
Warranty and Disclaimer
  • 180-day warranty from delivery, covering repairs or replacements for malfunctions attributable to AUTOMAX.
  • AUTOMAX is not liable for damages from misuse or non-compliance with specifications.
Handling Instructions
  • Supports nylon and urethane tubing with specific precision and bending radius requirements.
  • Non-genuine tubing may lead to disconnection or air leakage.
Guidelines for Nylon and Urethane Tubes
  • Avoid extremely soft tubing to prevent a drop in pull-out strength.
Tubing Installation Precautions
  • Ensure tubing is cut at a right angle and fully inserted to prevent leakage.
Tubing Removal Precautions
  • Ensure internal pressure is at atmospheric level before removal.
Installation Guidelines
  • Install away from direct impact and vibration, follow specified screw tightening torques.
Air Control Direction
  • Follow diagrams for correct control and free flow direction.
Connector Cover and Mounting Brackets
  • Open connector covers for settings and use index labels for recording information.
Handling Instructions and Precautions
  • Ensure correct connector cover positioning and lead wire insertion.
Mounting and Removing Devices
  • Follow specified torque values for mounting to avoid damage.
Flow Rate Characteristics and Specifications
  • Flow rate characteristics vary based on product and usage conditions.
Setting Device and Battery Unit Specifications
  • Includes power supply, indicators, and applicable sensor switches.
Guidelines for Battery and Sensor Usage
  • Periodically charge the battery unit if unused for long periods.
Specifications and Connections
  • Requires a power supply voltage of 12 to 42 VDC.
Device and Cable Specifications
  • Various models available with different tube diameters and flow rate types.
Warranty and Liability
  • 180-day warranty covering defects in material and workmanship.
See more

Catalog excerpts

Electronic Air Flow Controller GCD-1

GCD Automax presents a new actuator controller ! First in the industry Electronic Flow Controller Constantly monitors and corrects cylinder takt time automatically! Takt Time Controller New release! Air cylinders can operate continuously at set takt time (operation time). Avoid equipment stoppage and eliminate adjustments due to variations in takt time. Monitoring errors helps predictive maintenance and quality stabilization. Takt Time Controller iB-Flow main unit Setting device All products are RoHS compliant

 Open the catalog to page 1
Electronic Air Flow Controller GCD-2

Takt Time Controller Piping and wiring image 1 Piping and wiring image 2 <When using Takt Time Controlled Automatic takt time corrections Operation time observable Safe lock mechanism Takt Time Controller constantly monitors and makes corrections. First step leading to full automation in production lines. Digital setting of cylinder takt time (operation time). Troublesome cylinder operation time adjustment is done automatically. Safety mechanism prevents needle from loosening. Digital needle opening control Numeric setting of needle opening (0 to 100%). Change from analog to digital makes fl...

 Open the catalog to page 2
Electronic Air Flow Controller GCD-3

/\ CAUTION Read the safety precautions on page Q before using IhijBFoduct" Equipment stoppage because of takt time (operation time) variations Time and work required to adjust variations • Manual speed (fi ow rate) adjustment takes time • Loose needle problems due to human and external factors Cause 1 Variations in sliding 1 resistance of equipment Problem solved by using iB-Flow main unit and setting device. iB-Flow main unit Setting device (only used when doing settings) Cause 3 Changes due to aging of the cylinder itself Real effect Takt time varies mprovel productivity! and jpredictivelmaintenancelbvicombininql...

 Open the catalog to page 3
Electronic Air Flow Controller GCD-4

Takt Time Controller is used to control the cylinder takt time (operation time) automatically In the past... Variations in pressure and cylinder s sliding resistance cause fluctuations in cylinder takt time that may stop equipment. Considering variations in cylinder takt time cannot improve the overall takt time of the equipment. Cylinder speed varies so an expensive electric robot had to be used. There was a lot of maintenance work because of the fluctuations in takt time. Using the Takt Time Controller Equipment operates smoothly because takt time is corrected automatically even if takt time...

 Open the catalog to page 4
Electronic Air Flow Controller GCD-5

When using a single unit Double acting cylinder Sensor switch Note Sensor switch Note Note: Use of a 3-lead wire PNP output type solid-state sensor switch is not supported. Also, use a solid state sensor switch with internal drop voltage of iB-Flow no more than 4.5V. main unit Free flow Control flow Free flow Symbol Free flow iB-Flow main unit Control flow Control flow Sensor switch output Supplied air I/O cable GCD-ESUSB cable Takt Time Controller No. Error output Power connector 0V and I/O connector GND are connected internally. Use support software to do settings. Computer is only needed when...

 Open the catalog to page 5
Electronic Air Flow Controller GCD-6

Auto adjustment of double acting cylinder operation time (cycle time) Auto Set Mode The ON/OFF signals of the sensor switches at either stroke end of the cylinder are sent via the iB-Flow main unit to the setting device. The cylinder operation time is measured and the needle opening (throttling ratio) is adjusted accordingly. 1. Use an I/O cable to connect the setting device and iB-Flow main unit. 2. Set the target times for the extended (push) side and the retracted (pull) side. 3. If you perform a number of reciprocal cylinder operation cycles by manually operating the solenoid valve, the cylinder...

 Open the catalog to page 6
Electronic Air Flow Controller GCD-7

Auto adjustment of double acting cylinder operation time To adjust the cylinder speed, each numeric target operation time (takt time) for extending and retracting side is input into the setting device, and the speed is adjusted automatically. Takt time management of a device is simple, which greatly reduces adjustment work. Speed adjustment is performed by measuring actual operation time, so differences between individual cylinders, piping distances, and other issues are not factors. For details, see the application example on page 5 . Target time setting Setting range: 0.05 to 30 seconds Setting...

 Open the catalog to page 7
Electronic Air Flow Controller GCD-8

Always read these precautions carefully before use. Safety Precautions (iB-Flow) Before selecting and using the products, please read all the Safety Precautions carefully to ensure proper product use. The Safety Precautions described below are to help you use the product safely and correctly, and to prevent injury or damage to you, other people, and assets. Always be sure to comply with the following safety regulations: ISO4414 (Pneumatic fluid power - General rules and safety requirements for systems and their components) and JIS B 8370 (General rules relating to systems). The directions are...

 Open the catalog to page 8
Electronic Air Flow Controller GCD-9

residual air will still be in the compressor or storage tank. The actuator may move abruptly if residual air pressure remains inside the piping, causing injury. • Use safety circuits or design a system that prevents damage to machinery and personal injury when the machine is shut down due to an emergency stop or electrical power failure. • Before performing any kind of wiring work, be sure to turn off power. Failure to do so creates the risk of electric shock. • Do not allow lead wires and other cords to become damaged. Allowing a cord to become cut, bent excessively, pulled, rolled up, or squeezed...

 Open the catalog to page 9
Electronic Air Flow Controller GCD-10

• Installation 1. Though there are no restrictions on the installation direction, the unit should be installed where it will not be directly subjected to strong impact and/or vibration. 2. Screw tightening torque when using the iB-Flow main unit mounting holes or a bracket are 0.5 N-m [4.4 in-lbf] for an M3 screw and 1.0 N-m [8.9 in-lbf] for an M4 screw. Exceeding the specified tightening torque may damage the iB-Flow main unit, the bracket, etc. 3. Use in a location or environment like those described below should be avoided because doing so can cause the product to malfunction. If the product...

 Open the catalog to page 10

All AUTOMAX catalogs and technical brochures

  1. Vacuum Filter

    12  Pages

  2. Vacuum Valve

    28  Pages

  3. Flow sensor

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.