Catalog excerpts
heavy duty industrial solutions since 1973
Open the catalog to page 1performance • reliability • flexibility Battery charging rectifiers pg. 21 Batteries - Battery monitoring units pg. 35
Open the catalog to page 3Our production AUNILEC’S production is located in Verona Italy; thanks to a modern plant and automated processes we secure high production capabilities. Important investments have been made to meet customers’ most different needs and guarantee prompt delivery performances.
Open the catalog to page 4Customised solutions Thanking to 40 years acquired experience and technical know-how, our partner is offering customised solutions addressed to the industrial market. Customers’ specifications are expertly analysed since the proposal stage. Detailed and explanatory proposals are submitted for customer easy scrutiny. Our partner provides the following proposal estimation services: - Comprehensive technical and commercial offers - Consultancy and design studies - Drawing up of documentation upon request - Expediting and testing during installation - Final testing with customer attendance -...
Open the catalog to page 5We have been supplying energy since 1973 Environmental sustainability is our main aim Our partner was founded in 1973 designing and We invest many resources to try minimize the environmental manufacturing AC/DC power supplies for industrial use. Since the beginning, the Company has been managed and products, transferring this experience to its customers to meet demanding requirements from prime Customers such us, Engineering Companies, both Italians and international. We, always Customer oriented: The capability of listening market requests, the progressive technology innovation, the...
Open the catalog to page 6Sturdiness and performances: Aunilec: when organisationour philosophy becomes efficiency Aunilec products are designed to stand the harshest operating and environmental conditions. We meet the strictest requirements in terms of quality, reliability and efficiency. Any kind of Client customisation request is implemented but to be in respect of International Standards and physical concepts too. Our Power Converters provide exceptional reliability and extraordinarily extended MTBF (Mean Time Between Failure) secured by the adoption of conservative design methods, control Flexibility and...
Open the catalog to page 7Digital static UPS unit 1Ph or 3Ph Main features: Double rectifier 125 Vdc 1250A Double inverter 125 Vdc 100KVA Change over switchboard installed in Hassi R Mell Solar Plant (Algerian desert) High flexibility, allowing our equipment to adapt to all system features The DPS is suitable for a wide range of applications in the most demanding industrial environments. It allows to achieve complex system architectures to ensure maximum power availability with a wide range of accessories and optional. We can supply redundant N+1 or HOT STANDBY configurations. Thanks to the new our DIGITAL...
Open the catalog to page 10Battery management system: maximising life Low consumption levels Thanks to component sizing, the UPS systems can reach high efficiency levels even with low DC bus voltages. The selectable Line Interactive mode may be used in stable environments to achieve very high efficiency levels (~98%) in case of inverter power supply failure, and when synchronised with the mains it can take on the load in less than 1ms. When the system is powered by the mains, the UPS recharges the batteries. In case of mains failure power is supplied to the inverter from the batteries. Efficient battery management,...
Open the catalog to page 11Voltage Battery Output Voltage (Other size on request)
Open the catalog to page 12Input frequency Frequency range Input voltage Input voltage range Input THD INPUT ELECTRIC PARAMETERS 50 / 60 Hz ±10% 400 Vac 3PH ±10% 27% with 6P, 12% with 12P, 6% with 12P + THD filter Temperature compensation, 3 probes Ripple OUTPUT ELECTRIC PARAMETERS Overload 110/125/150% 2h/10'/10” Output sinusoid distortion<2% (VFI-SS-III class in compliance with the IEC/CEI EN 62040 standard) Dynamic stability -8%/+13% restoration to ±1% in 80ms Static switch switching <1ms Remote signalling Remote controls Communication Cooling Operating conditions Noise COMMUNICATIONS Voltage-free...
Open the catalog to page 13Industrial uninterruptible power supply Main features: - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery conservation and life - Pure output sinusoidal wave VFI-SS-III in accordance with the CEI EN 62040 standards - Intelligent Fan Speed controller - charge mode for AGM, flooded batteries, GEL , Ni-Cd and Lithum - settable alarms thresholds - Voltage recharge with temperature compensation for an highest battery life - digital microprocessor controller, for the highest inverter reliability - full opto isolation on...
Open the catalog to page 14Incoming VEGA includes a performing system for to be powered from generating sets. The input is optimized thanks to the softstart and constant monitoring of input factors. Fields of application VEGA is suitable for any kind of application, from computer industry to the most demanding industrial loads. Thanks to the wide range of fittings and options, is possible to achieve most difficult configurations and articulated architectures. Redundant, hot stand-by and parallel configurations are achievable to grant the maximum availability to the power supply. VEGA includes: - VFI double...
Open the catalog to page 15INPUT Rated Voltage Rated Voltage tolerance (%) Rated Frequency (Hz) Soft start Frequency tolerance Standard equipment BATTERIES Type Ripple Temperature compensation Typical charging current 380 - 400 - 415 Vac 3Ph 400 V + 20% /- 25% 45 f 65 Hz 0 f 100% in 30'' ± 2% Back Feed protection; separable bypass line; EPO lead, flooded, VRLA AGM / GEL; NiCd -- Lithium < 1% - 0.5 Vx°C 0.1 x C10 OUTPUT Rated output power (kVA) Active power (kW) Number of phases Rated voltage phase); 3Ph + N 400 Vac 3Ph + N (in single-phase VM versions, the ouput voltage is 230Vac single- Static stability Dynamic...
Open the catalog to page 16INPUT Rated Voltage Rated Voltage tolerance (%) Rated Frequency (Hz) Soft start Frequency tolerance Standard equipment BATTERIES Type Ripple Temperature compensation Typical charging current OUTPUT Rated power (kVA) Active power (kW) Number of phases Rated voltage Static stability Dynamic stability Voltage distortion Crest factor (lpeack/lrms) Frequency stability on battery Frequency Overload 380 - 400 - 415 Vac 3Ph 400 V + 20% /- 25% 45 f 65 Hz 0 f 100% in 30'' ± 2% Back Feed protection; separable bypass line; EPO lead, flooded, VRLA AGM / GEL; NiCd -- Lithium < 1% - 0.5 Vx°C 0.1 x C10 3Ph...
Open the catalog to page 17All AUNILEC catalogs and technical brochures
-
Datasheet MULTI PLUS
5 Pages
-
Datasheet IRIS+
2 Pages
-
Datasheet IRIS-RT 6-10
2 Pages
-
Datasheet IRIS-LFP 1-3
2 Pages
-
Datasheet IRIS-LFP 6-10
4 Pages
-
Datasheet IRIS+L
2 Pages
-
Datasheet HELIOS TH
4 Pages
-
Datasheet AUPUS HE 5U
5 Pages
-
DAtasheet AUPUS HE Cabinet
6 Pages
-
Datasheet AUPUS-OC0864
5 Pages
-
Datasheet AUPUS WRS
4 Pages
-
Datasheet VEGA HE
4 Pages
-
Datasheet Multi Plus News
10 Pages
-
Datasheet HELIOS MPW
8 Pages
-
Datasheet MHE AUPUS C
4 Pages
-
Datasheet AESB-R
2 Pages
-
Aunilec Datasheet AESB EN
2 Pages
-
ARES RT 1000-3000VA
2 Pages
-
ARES 1000-3000VA
2 Pages
-
EPC D 600/800VA
2 Pages
-
Aunilec ARES
2 Pages
-
after-sales service
6 Pages
-
Aunilec MLTDSP datasheet EN
2 Pages
-
After-sales service Aunilec
6 Pages
-
Inverters AUPUS EIM
3 Pages
-
Controllers VIDI AUPUS C
4 Pages
-
AESATM/TT 10-80kVA
3 Pages
-
CRFw 12Vcc, 24Vcc and 48Vcc
2 Pages
-
INV 48V/300VA
1 Pages
-
Active power filter 400V
2 Pages
-
Aunilec Battery analyzer
1 Pages
-
Aunilec Batteries
1 Pages
-
Aunilec DSP Power Solutions
4 Pages
-
Aunilec VEGA
6 Pages
-
Aunilec ARFDin
2 Pages
-
Power factor correction B50
4 Pages
-
Power factor correction B35
4 Pages
-
Power factor correction B25
4 Pages
-
Série EOS|D 650-2200VA
2 Pages
-
Série EOS 650-2200VA
2 Pages
-
NET600 600VA
2 Pages
-
Datasheet INV
3 Pages
-
Datasheet DSP
4 Pages
-
Datasheet MultiPlus
4 Pages
-
Datasheet OP 5_10kVA
2 Pages
-
Datasheet OP 1_3kVA
2 Pages
-
Datasheet CRFw
2 Pages
-
Datasheet ARFDin
2 Pages
-
Datasheet helios modular
4 Pages
-
Datasheet Helios 20S
2 Pages
-
Datasheet Helios STR
2 Pages
-
Datasheet MPTR
2 Pages
-
Datasheet RDC
4 Pages
Archived catalogs
-
Datasheet Aunisol 1-20
2 Pages
-
Datasheet Aunisol 3-5-10
4 Pages
-
Datasheet charger AUPUS WRS
4 Pages
-
Datasheet AESA
2 Pages
-
HELIOS MPW
7 Pages
-
AUPUS HE Cabinet
6 Pages
-
Power solutions
48 Pages
-
Protection and energy saving
61 Pages
-
UPS catalogue 2019-2020
60 Pages
-
Gel batteries
2 Pages
-
Carbon battery
3 Pages
-
Charger CRFD
2 Pages
-
Datasheet ARES Rack
2 Pages
-
Aunilec MLTDSP Brochure EN
4 Pages
-
Live&smart MLTDSP EN
2 Pages
-
Live&smart AUNISOL EN
2 Pages
-
Lead Carbon battery
2 Pages
-
Aunilec battery 12 years EN
2 Pages
-
Datasheet RCRFn
2 Pages
-
Catalogue Power solutions
48 Pages