Catalog excerpts
Automatic voltage optimisers EcoREG series Automatic voltage optimisers Automatic voltage stabilisation is a key function that sets EcosREG voltage optimisers apart from simple autotransformers, which also reduce voltage but cannot guarantee certain savings due to the continuous voltage variations of the mains, in order to prevent the delivered voltage from dropping excessively low as a consequence of mains fluctuations, autotransformers can never provide maximum savings. Power supply and professional users A common misconception about VO is that a reduction in voltage will result in an increase in current and therefore power consumed will remain constant. This is true for certain fixed-power loads, however most sites have a diversity of loads that will benefit to a greater or lesser extent with energy savings aggregating across a site as a whole. The benefit to typical equipment at three phase sites is discussed next page.
Open the catalog to page 1Onduleurs • Redresseurs • Batteries Onduleurs • Redresseurs • Batteries Automatic voltage optimisers EcoREG series Voltage optimisers THREE PHASE AC MOTORS: The three phase induction motor is one of the most common types of three phase loads and is used in many items of equipment including refrigeration, pumps, compressors, fans, air conditioning, conveyor drives and lifting systems. Overvoltage results in flux saturation of the iron core, wasting energy through eddy currents. Increased hysteresis losses. The drawing of excessive current results in excess heat output from copper losses. The...
Open the catalog to page 2Automatic voltage optimisers EcoREG series Voltage optimisers proposal Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage "optimisation” devices have a fixed voltage adjustment, others electronically regulate the voltage automatically. Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply. Overvoltage leads to...
Open the catalog to page 3Saving and return on investment There are many factors which contribute to saving energy and reduce the payback period: a.Mains voltage which is not always close to rated value. Voltage is usually higher late at night: 10% higher than the rated value is a common condition. This level is often exceeded when the user is located near an electric substation. Saving increases to approximately 20% when the voltage exceeds 10% of the rated value. b.Type of powered device. Some devices allow higher saving than others and some electric devices do not provide any significant saving at all. Voltage...
Open the catalog to page 4Automatic voltage optimisers EcoREG series HIGHLIGHTS Voltage optimisers The dwindling fossil fuel reserves, the need to reduce carbon dioxide emissions and lower availability of financial resources has spurred energy production from renewable sources and strongly boosted the development of technology for optimising (limiting) electricity consumption. EcoREG automatic voltage optimisers are one of the solutions offered by new technologies to users. These devices comply with the requirements of IEC 60038 for electric equipment operating tolerances and supply an operating voltage which...
Open the catalog to page 5Automatic voltage optimisers EcoREG series Models capable of broader input voltage variations may be built on demand. These may be needed because voltage may sometimes exceed the 10% tolerance specified in the supply contract. Automatic voltage stabilisation is a key function that sets EcoREG voltage optimisers apart from simple autotransformers, which also reduce voltage but cannot guarantee certain savings due to the continuous voltage variations of the mains. In order to prevent the delivered voltage from dropping excessively low as a consequence of mains fluctuations, autotransformers...
Open the catalog to page 6Voltage optimisers Automatic voltage optimisers EcoREG seriesOperating principle An electronic control circuit detects the voltage delivered by the voltage optimiser and compares it to a reference voltage. If the difference between the output voltage and the reference voltage exceeds the preset tolerance limits, an error signal is generated; this signal may be either negative or positive according to whether the output voltage is lower or higher than the preset value. This signal activates the servomotor which moves the mobile contacts (electrographite rollers / brushes) of the variable...
Open the catalog to page 7Onduleurs • Redresseurs • Batteries General features Operating temperature. EcoREG voltage optimisers are designed tor operation at a maximum ambient temperature of 40°C in the most demanding conditions: continuous duty, full load and minimum input voltage. Models suitable for higher temperatures are manufactured on request. Degree of protection. IPOO, IP21, IP54 INDOOR and IP54 OUTDOOR. Cooling system. All IP21 models are designed for natural air convection - FAN-FREE. IP54 models are cooled by fans or by air conditioning depending on the ambient conditions. Reliability. EcoREG voltage...
Open the catalog to page 8EcoREG B - single-phase M and three-phase T/YECOREG M SINGLE-PHASE 230V 50/60HZ VOLTAGE OPTIMISERS - IP21 INDOOR MODELS Model Input voltage Output regulation Response variation range time ECOREG T THREE-PHASE 400V 50/60HZ VOLTAGE OPTIMISERS - IP21 INDOOR MODELS Rated power (KVA) Input voltage variation Output regulation range Response time Dimensions axbxh(mm) Output accuracy Fittings: Alarm indication and dry contacts for connection to an external device for protection against: overload, over/under voltage Potentiometer to adjust the stabilised output voltage Digital network...
Open the catalog to page 9EcoREG S - single-phase M and three-phase T/Y ECOREG M SINGLE-PHASE 230V 50/60HZ VOLTAGE OPTIMISERS - IP21 INDOOR MODELS Model Input voltage variation (±%) Output regulation range (%) Response time (ms/V) Output accuracy Weight (kg) (%) Dimensions axbxh(mm) ECOREG T THREE-PHASE 400V 50/60HZ VOLTAGE OPTIMISERS - IP21 INDOOR MODELS Rated power (KVA) Output accuracy Dimensions axbxh(mm) Input voltage variation (±%) Output regulation Response range time ECOREG Y THREE-PHASE + N 400V 50/60HZ VOLTAGE OPTIMISERS - IP21 INDOOR MODELS ECOREG-Y306AJ-15S Fittings: Alarm indication and dry...
Open the catalog to page 10All AUNILEC catalogs and technical brochures
-
Datasheet MULTI PLUS
5 Pages
-
Datasheet IRIS+
2 Pages
-
Datasheet IRIS-RT 6-10
2 Pages
-
Datasheet IRIS-LFP 1-3
2 Pages
-
Datasheet IRIS-LFP 6-10
4 Pages
-
Datasheet IRIS+L
2 Pages
-
Datasheet HELIOS TH
4 Pages
-
Datasheet AUPUS HE 5U
5 Pages
-
DAtasheet AUPUS HE Cabinet
6 Pages
-
Datasheet AUPUS-OC0864
5 Pages
-
Datasheet AUPUS WRS
4 Pages
-
Datasheet VEGA HE
4 Pages
-
Datasheet Multi Plus News
10 Pages
-
Datasheet HELIOS MPW
8 Pages
-
Datasheet MHE AUPUS C
4 Pages
-
Datasheet AESB-R
2 Pages
-
Aunilec Datasheet AESB EN
2 Pages
-
ARES RT 1000-3000VA
2 Pages
-
ARES 1000-3000VA
2 Pages
-
EPC D 600/800VA
2 Pages
-
Aunilec ARES
2 Pages
-
Power solutions catalogue
48 Pages
-
after-sales service
6 Pages
-
Aunilec MLTDSP datasheet EN
2 Pages
-
After-sales service Aunilec
6 Pages
-
Inverters AUPUS EIM
3 Pages
-
Controllers VIDI AUPUS C
4 Pages
-
AESATM/TT 10-80kVA
3 Pages
-
CRFw 12Vcc, 24Vcc and 48Vcc
2 Pages
-
INV 48V/300VA
1 Pages
-
Active power filter 400V
2 Pages
-
Aunilec Battery analyzer
1 Pages
-
Aunilec Batteries
1 Pages
-
Aunilec DSP Power Solutions
4 Pages
-
Aunilec VEGA
6 Pages
-
Aunilec ARFDin
2 Pages
-
Power factor correction B50
4 Pages
-
Power factor correction B35
4 Pages
-
Power factor correction B25
4 Pages
-
Série EOS|D 650-2200VA
2 Pages
-
Série EOS 650-2200VA
2 Pages
-
NET600 600VA
2 Pages
-
Datasheet INV
3 Pages
-
Datasheet DSP
4 Pages
-
Datasheet MultiPlus
4 Pages
-
Datasheet OP 5_10kVA
2 Pages
-
Datasheet OP 1_3kVA
2 Pages
-
Datasheet CRFw
2 Pages
-
Datasheet ARFDin
2 Pages
-
Datasheet helios modular
4 Pages
-
Datasheet Helios 20S
2 Pages
-
Datasheet Helios STR
2 Pages
-
Datasheet MPTR
2 Pages
-
Datasheet RDC
4 Pages
Archived catalogs
-
Datasheet Aunisol 1-20
2 Pages
-
Datasheet Aunisol 3-5-10
4 Pages
-
Datasheet charger AUPUS WRS
4 Pages
-
Datasheet AESA
2 Pages
-
HELIOS MPW
7 Pages
-
AUPUS HE Cabinet
6 Pages
-
Power solutions
48 Pages
-
Protection and energy saving
61 Pages
-
UPS catalogue 2019-2020
60 Pages
-
Gel batteries
2 Pages
-
Carbon battery
3 Pages
-
Charger CRFD
2 Pages
-
Datasheet ARES Rack
2 Pages
-
Aunilec MLTDSP Brochure EN
4 Pages
-
Live&smart MLTDSP EN
2 Pages
-
Live&smart AUNISOL EN
2 Pages
-
Lead Carbon battery
2 Pages
-
Aunilec battery 12 years EN
2 Pages
-
Datasheet RCRFn
2 Pages
-
Catalogue Power solutions
48 Pages