video corpo

Fiche technique Aunilec conditionneurs EN
8Pages

{{requestButtons}}

Catalog excerpts

Fiche technique Aunilec conditionneurs EN - 1

Onduleurs • Redresseurs • Batteries Onduleurs • Redresseurs • Batteries Line conditioners Line conditioners REG Series Line conditioners Line conditioners have been designed to provide the highest level of protection to electrical appliances connected to distribution lines disturbed by sudden voltage variations, HF noises and spikes. Statistically, these phenomena represent more than 95% of electric anomalies that could be the cause of breakdowns and poor operation of any kind of appliance connected to distribution lines. The range is made up of models with powers that vary from 0.5 to 950 kVA and use two different voltage regulation technologies: a.static switching technology for loads with single-phase absorption (up to 4 kVA) and three phase (up to 24 kVA) b.electrodynamic regulation technology via series transformer and variable autotransformer for loads with three-phase absorption (up to 950 kVA). The two regulation technologies and the wide range allow the most suitable regulation system to be supplied to meet the specific needs of the various kinds of appliances. The standard models embody four different devices each one devoted to the compensation or attenuation of a specific electrical fault: • a suppressor of voltage spikes • a line filter • a high attenuation isolating transformer • a voltage regulator

Open the catalog to page 1
Fiche technique Aunilec conditionneurs EN - 2

Line conditioners REG Series Line conditioners proposal REG-TS AND REG-TST ELECTRONIC LINE CONDITIONERS They have specific performances to power electronic appliances with medium to low powers that require a particularly high stabilisation speed such as: process and numerical controls, robotics, medical equipment, telecommunications and computers. The range is made up of standard models with powers ranging from 0.5 to 24 kVA. Furthermore, because the manufacturing criteria make these conditioners highly versatile, on request, versions can be designed with customised specifications for the...

Open the catalog to page 2
Fiche technique Aunilec conditionneurs EN - 3

Line conditioners REG Series REG-TS - Electronic line conditioners The range is made up of single-phase models with powers ranging from 500 VA to 4 kVA. The noiseless operation, the compact size and fitness for use make them ideal for installation in offices and laboratories as well as in professional applications like automotive, chemical, food and telecommunications industry. It is a range that progressively extends following requests of customers with particular needs regarding voltage, dimensions, protection degree, engineering and specific needs including, for example, the need to: •...

Open the catalog to page 3
Fiche technique Aunilec conditionneurs EN - 4

Electronic line conditioners REG-TS, REG-TST Power Number Input voltage (KVA) of phases V . ^ Rated current Standards Weight Dimensions mm r. voltage . , . . Figure Fittings I = Main breaker IM = Thermal magnetic circuit breaker CF = Frequency selector 50/60 Hz L = "mains on" pilot lamps CT = Voltage selector F = Input fuse M = Terminal board connection FF = Ultra rapid output fuse BT = Electronic voltage relay (on request) PT = Thermal protection O = OVD protection OTHER FEATURES Impedance: 0.3 to 11 Ohm depending on models No-load current: 40 to 700mA depending on...

Open the catalog to page 4
Fiche technique Aunilec conditionneurs EN - 5

Line conditioners REG-TS, REG-TST Series General features TRANSIENT VOLTAGE SUPPRESSOR This device is intended to limit transverse and common mode spikes exceeding the input voltage peak value. Transient voltage protection can also be effective on spikes of atmospheric origin over 6kV. RFI FILTERS They attenuate high frequency transverse and common mode interferences over 300 kHz. ISOLATION TRANSFORMER It is featured by low output impedance, insensitivity to load power factor, high attenuation and functional and dielectric isolation. The F thermal class transformer has a recessed concentric...

Open the catalog to page 5
Fiche technique Aunilec conditionneurs EN - 6

Onduleurs • Redresseurs • Bdtteries Onduleurs • Redresseurs • Bdtteries Electrodynamic line conditioners They provide a maximum level of protection to high power appliances, with high electromagnetic susceptibility, connected to distribution lines disturbed by sudden voltage variations, high frequency interferences and voltage spikes. The regulation system is made up exclusively of magnetic components capable of supporting loads with high inrush currents. The use of electronic components is limited to the control of the mains and of magnetic components stabilising the voltage. Thanks to...

Open the catalog to page 6
Fiche technique Aunilec conditionneurs EN - 7

Electrodynamic line conditioners REG-YAC Series Electrodynamic line conditioners REG-YAC 3PH+N 230/400V 50/60Hz Independent regulation of each phases Power Rat6d, VOltt9e R“p0nSe Accuracy Standards De?re*of current variation time fittings Protfpction Wei9htkg axbxh Figure Aunilec LCs are designed to deliver the declared power permanently (24/7) under the worst operating conditions, i.e. at full load, at minimum input voltage and max input current and at the declared ambient temperature. Standard fittings: V = Voltmeter L = pilot lamps HF = High frequency filter PS = Spike protection IT =...

Open the catalog to page 7
Fiche technique Aunilec conditionneurs EN - 8

Electrodynamic line conditioners TVP TRANSIENT VOLTAGE SUPPRESSORS The protection against transient overvoltages generated by atmospheric discharges or by switching process is carried out by type 2 (cat. C) surge arresters complying with EN 61643-11/VDE 0675, part 6-11 characterised by a nominal discharge current (8/20) In of 40 (or 60) kA, by a discharge current with Imax impulse of 50 (or 110) kA, a Up protection level not greater than 1300 V and a response time tA shorter than 25 ns. ISOLATION TRANSFORMER This component, thanks to the electrostatic shield inserted between primary and...

Open the catalog to page 8

All AUNILEC catalogs and technical brochures

  1. Aunilec ARES

    2 Pages

  2. Aunilec VEGA

    6 Pages

  3. NET600 600VA

    2 Pages

Archived catalogs

  1. HELIOS MPW

    7 Pages

  2. Charger CRFD

    2 Pages