Aunilec battery 12 years EN - 1

^ilec> Onduleurs • Redresseurs • Batteries Applications UPS Rectifiers Central sources 12 years Long life batteriesSealed lead acid 5,2Ah to 260AhFeatures and innovations AUNISOLBAT batteries 12ET-L series are used specifically for the inverters, rectifiers battery chargers and central sources of security lighting. The tight construction of the battery allows operation without problems in all positions. Since No specific maintenance and servicing is required with an operation based on the principle of the gas recombination (99%). The latest innovations allow you to use these batteries in both floating or cycling without reducing its service life or ability. In addition the ABS tray provides robustness with resistance to shock, vibration, chemicals and heat. Our batteries are declared not dangerous by the FFA and IATA. • Maintenance free, sealed design without water • Up to 12 years life time at 20 ° C (nominal residual capacity of 80%) • Plates using the entire space in the tray • Electrolyte low impurity levels • Self-discharge very low with less than 3% per month at 20 ° C • Storage capacity of +/- 12 months at 20 ° C • Parallel mount and wide operating temperature range • recyclable product Temperature compensation of load To preserve the long life of our batteries, it is advisable to compensate the charge voltage in floating to room temperature. The focus is to 2.275V / cell and 20 ° C, we recommend - 3 mV / ° C for temperatures above 25 ° C and + 3 mV / ° C for temperatures below 15 ° C. It will be necessary to add the optional temperature probe and to placed it close to the batteries.

Open the catalog to page 1
Aunilec battery 12 years EN - 2

Applications | UPS | Rectifiers | Central sources Load specifications Floating - The optimum float voltage for a battery depends on the temperature; between 15 and 24 0 C, the recommended value is between 2,27 and 2,30V. It is recommended to install the batteries in a room or the temperature is regulated, knowing that the float voltage can be increased or decreased to compensate the temperature variations. The setting is +/- 3 mV per0 C. The most suitable protocol to charge the batteries in order to maximize service life and performance, is a constant voltage charging with initial current...

Open the catalog to page 2

All AUNILEC catalogs and technical brochures

  1. HELIOS MPW

    7 Pages

  2. Charger CRFD

    2 Pages

  3. Aunilec ARES

    2 Pages

  4. Aunilec VEGA

    6 Pages

  5. NET600 600VA

    2 Pages