Onduleurs • Redresseurs • Batteries Applications | Industry | Healthcare | Datacenter Active Power Filter Power Factor Correction The Aunilec APF not only compensate harmonic current but also the reactive power. It is able to correct for either a leading or lagging power factor. Modular design, easy to extend Up to 12 harmonic orders selective individually Close/open Loop control Improves lagging and leading power factor at input loads Unbalanced loads compensation Reduces apparent power consumption at the supply and saves costs Resolves nuisance tripping of MCCBs Programmable power factor correction Full-time DSP control system Easy selection and maintenance Shunt connection Flexible upgrading and redundancy Parallel operation with different capacity User friendly LCD control panel Rack/wall installation THD= 0.1% THD= 0.1% THD= 0.1% THD= 2.4% THD= 2.4% THD= 2-4% The user friendly LCD display offers access to all parameters, waveforms, harmonic spectrum system power quality, settings, status and alarms, Close/Open Loop Control The CT is allowed to install at source or load side for measure the harmonic current from the load. When CT is installed at source side, the close loop control method is used for best accuracy of harmonic current compensation. (When CT is installed at the load side, the open loop control will be used). Harmonic Current Generator The Aunilec APF behaves like a harmonics current generator. It will measure the harmonic generated from the non-linear loads and cancel these harmonics with a newly generated, opposite phase shifted harmonics current of the same amplitude.
Open the catalog to page 1Applications | Industry | Healthcare | Datacenter Onduleurs • Redresseurs • Batteries Input voltage Compensated harmonic orders Power Factor correction Response time Controllable power module Number of power module Dimensions (WxDxH) Input voltage De-rating compensation current/phase Max. compensation current for neutral Inrush current Current limitation Dimensions (WxDxH) Storage temperature Operating temperature Relative humidity Harmonic and design standards Software (optional) Control panel Compensate both lagging and leading reactive power (programmable) Can be set, primary current:...
Open the catalog to page 2All AUNILEC catalogs and technical brochures
-
Datasheet MULTI PLUS
5 Pages
-
Datasheet IRIS+
2 Pages
-
Datasheet IRIS-RT 6-10
2 Pages
-
Datasheet IRIS-LFP 1-3
2 Pages
-
Datasheet IRIS-LFP 6-10
4 Pages
-
Datasheet IRIS+L
2 Pages
-
Datasheet HELIOS TH
4 Pages
-
Datasheet AUPUS HE 5U
5 Pages
-
DAtasheet AUPUS HE Cabinet
6 Pages
-
Datasheet AUPUS-OC0864
5 Pages
-
Datasheet AUPUS WRS
4 Pages
-
Datasheet VEGA HE
4 Pages
-
Datasheet Multi Plus News
10 Pages
-
Datasheet HELIOS MPW
8 Pages
-
Datasheet MHE AUPUS C
4 Pages
-
Datasheet AESB-R
2 Pages
-
Aunilec Datasheet AESB EN
2 Pages
-
ARES RT 1000-3000VA
2 Pages
-
ARES 1000-3000VA
2 Pages
-
EPC D 600/800VA
2 Pages
-
Aunilec ARES
2 Pages
-
Power solutions catalogue
48 Pages
-
after-sales service
6 Pages
-
Aunilec MLTDSP datasheet EN
2 Pages
-
After-sales service Aunilec
6 Pages
-
Inverters AUPUS EIM
3 Pages
-
Controllers VIDI AUPUS C
4 Pages
-
AESATM/TT 10-80kVA
3 Pages
-
CRFw 12Vcc, 24Vcc and 48Vcc
2 Pages
-
INV 48V/300VA
1 Pages
-
Aunilec Battery analyzer
1 Pages
-
Aunilec Batteries
1 Pages
-
Aunilec DSP Power Solutions
4 Pages
-
Aunilec VEGA
6 Pages
-
Aunilec ARFDin
2 Pages
-
Power factor correction B50
4 Pages
-
Power factor correction B35
4 Pages
-
Power factor correction B25
4 Pages
-
Série EOS|D 650-2200VA
2 Pages
-
Série EOS 650-2200VA
2 Pages
-
NET600 600VA
2 Pages
-
Datasheet INV
3 Pages
-
Datasheet DSP
4 Pages
-
Datasheet MultiPlus
4 Pages
-
Datasheet OP 5_10kVA
2 Pages
-
Datasheet OP 1_3kVA
2 Pages
-
Datasheet CRFw
2 Pages
-
Datasheet ARFDin
2 Pages
-
Datasheet helios modular
4 Pages
-
Datasheet Helios 20S
2 Pages
-
Datasheet Helios STR
2 Pages
-
Datasheet MPTR
2 Pages
-
Datasheet RDC
4 Pages
Archived catalogs
-
Datasheet Aunisol 1-20
2 Pages
-
Datasheet Aunisol 3-5-10
4 Pages
-
Datasheet charger AUPUS WRS
4 Pages
-
Datasheet AESA
2 Pages
-
HELIOS MPW
7 Pages
-
AUPUS HE Cabinet
6 Pages
-
Power solutions
48 Pages
-
Protection and energy saving
61 Pages
-
UPS catalogue 2019-2020
60 Pages
-
Gel batteries
2 Pages
-
Carbon battery
3 Pages
-
Charger CRFD
2 Pages
-
Datasheet ARES Rack
2 Pages
-
Aunilec MLTDSP Brochure EN
4 Pages
-
Live&smart MLTDSP EN
2 Pages
-
Live&smart AUNISOL EN
2 Pages
-
Lead Carbon battery
2 Pages
-
Aunilec battery 12 years EN
2 Pages
-
Datasheet RCRFn
2 Pages
-
Catalogue Power solutions
48 Pages