  • General Information: The document outlines various mounting positions for actuator controls, applicable to multi-turn and part-turn actuators of all sizes, including SA, SAR, SAEx, SAREx, SQ, SQR, SQEx, SQREx, and actuator controls in all versions (AM, AMEx).
  • Mounting Positions:
    • Position A: Standard position.
    • Position B: Not possible for SA multi-turn actuators with rising valve stems.
    • Position C: Alternative position.
    • Position D: Not possible for SA multi-turn actuators with rising valve stems.
  • Considerations: Space constraints should be considered when selecting mounting positions, which can be changed later if needed.
Mounting Positions for Local Controls
  • Position A-1: Selector switch pointing in actuator direction (standard).
  • Position B-1: Selector switch pointing lateral left.
  • Position C-1: Selector switch opposite the actuator.
  • Position D-1: Selector switch pointing lateral right.
  • Considerations: Space constraints should be considered, and positions can be changed later.
Mounting Positions for Electrical Connection
  • Position A-1: Cable entries in actuator direction (standard).
  • Position B-1: Cable entries located lateral left.
  • Position C-1: Cable entries located opposite the actuator.
  • Position D-1: Cable entries located lateral right.
  • Outdoor Installation: Ensure cable entries are downward or lateral to prevent water ingress.
  • Considerations: Positions can be changed later if needed.
Additional Notes: The document reserves the right to alter data based on improvements, rendering previous documents invalid.
See more

Catalog excerpts

SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1-1

SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1 Mounting positions Actuator controls on SA and SQ actuators 1. Mounting positions Actuator controls on actuator1) Mounting position A Please consider possible space constraints on site when selecting the mounting position. Mounting positions may easily be changed at a later date. 1) Mounting positions apply for the following actuators: Multi-turn actuators in all sizes: SA, SAR, SAEx, SAREx Part-turn actuators in all sizes: SQ, SQR, SQEx, SQREx Actuator controls in all versions: AM, AMEx 2) Attention: For SA multi-turn actuators with rising valve stems, mounting positions B and D are not possible. We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

 Open the catalog to page 1
SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1-2

SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1 Mounting positions Actuator controls on SA and SQ actuators 2. Mounting positions Local controls Mounting position A-1 (standard) Selector switch pointing in actuator direction Selector switch pointing lateral left Selector switch opposite the actuator Selector switch pointing lateral right Please consider possible space constraints on site when selecting the mounting position. Mounting positions may easily be changed at a later date. We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue...

 Open the catalog to page 2
SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1-3

SA 07.2 – SA 16.2/SQ 05.2 – SQ 14.2 AM 01.1 Mounting positions Actuator controls on SA and SQ actuators 3. Mounting positions Electrical connection Mounting position A-1 (standard) Cable entries in actuator direction Cable entries located lateral left Cable entries located opposite the actuator actuator ct ct Cable entries located lateral right Mounting positions may easily be changed at a later date. The mounting positions shown apply for all types of electrical connections. Attention: For outdoor installation, make sure that the cable entries are located in downward or later position to prevent...

 Open the catalog to page 3

All AUMA catalogs and technical brochures

  1. SAEx 07.2

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.