PRODUCT LEAFLET MODULOBLOC TRANSFORMERS Network Modulobloc Transformer (3200 V - 5500 V - 6600 V from 1 to 160 kVA)
Open the catalog to page 1PRODUCTS PRESENTATION SINGLE-PHASE SETS FOR SINGLE-PHASE NETWORKS A concentric two-pole cable or two single-pole cables SINGLE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS A three-pole cable or three single-pole cables THREE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS A three-pole cable or three single-pole cables
Open the catalog to page 2NETWORK TRANSFORMERS Modulobloc Type 1 to 160 kVA With independent connection interface
Open the catalog to page 3ALL THE ADVANTAGES OF EPOXY RESIN For sets, transformers and connection interfaces : single-phase from 1 kVA to 50 kVA or three-phase from 5 kVA to 160 kVA The use of epoxy resin guarantees that the transformers have the following characteristics : Corrosion resistant, remain unaltered over time. Watertight and immersible. Insulated. Can be buried into purposedely-deisgned pits. MODULOBLOC MAIN CHARACTERISTICS Watertight and immersible sets Conform to NFC 52 410 standards and CEI 76 Dielectric : Dry, epoxy, up to 6 kVA Oil from 8 to 160 kVA Primary insulation voltage : 7.2 kV Secondary...
Open the catalog to page 4DOUBLE « AUTO » PROTECTED TRANSFORMERS : Protection devices directly incorporated in the transformer guarantee : MV protection with easily-accessible HRC fuses Thermal protection using a thermal probe on a 1.5 meter long cable Optional : Low voltage protection using thermal-magnetic circuit breaker or fuses installed in a separate cabinet allowing protection against short circuiting with the possibility of several feeders. Starting from 8 kVA this protection can be integrated directly on the transformer. Stick fuse on the Three-phase TED-E 5 kVA Two-pole circuit breaker in a low Voltage...
Open the catalog to page 5MODULO BI RANGE Electrical modular equipment comprising the single-phase 3200 V network The range of MODULOBLOC products consists of TEE or TED-E transformers, IDR connection interfaces and annex equipment. IDR BI junction Two way junction allowing existing networks to conform to safety regulations and recommended NFC 17 200 standards. MODULO BI system with TEE 5 kVA single-phase transformer and IDR BI connection interface Three way junction bow allowing a two-phase concentric or twisted single-phase cable connection 6 to 25 mm² in cross section. All above sets have a checking compartment...
Open the catalog to page 6SINGLE PHASE TEE TRANSFORMER (1 to 8 kVA) SINGLE PHASE TEE TRANSFORMER FOR A SINGLE PHASE NETWORK MV cords L = 1.5 ml with plug / IDR The transformer is immersible IP68 modulobloc, in epoxy resin, dry type with the following characteristics : Coupling Primary voltage Secondary no load voltage Insulation voltage Power rating Power output rating* Thermal probe cable HO 7 RNF 2 x 1.5 mm² The transformer also comprises : Medium voltage input by two 1.5 meter-long flexible TEE 5kVA 3200 V / 230 V cables equipped with a single pole plug made in the factory, connectable to the IDR BI terminal....
Open the catalog to page 7SINGLE PHASE TED-E TRANSFORMER from 8 to 50 kVA SINGLE PHASE TRANSFORMER TED-E FOR A SINGLE PHASE NETWORK MV cords L = 1.5 ml with plug / IDR preapared 1 x 6 mm² + shield The transformer is immersible, in epoxy resin, oil type with the following characteristics : Coupling Primary voltage Secondary no load voltage Insulation voltage Power rating Power output rating* LV cable L = 1.5 ml HO 7 RNF 2 x 10mm² 10 kVA HO 7 RNF 2 x 25mm² 16 kVA HO 7 RNF 2 x 35mm² 25 kVA HO 7 RNF 2 x 50 mm² 32 kVA HO 7 RNF 2 x 95mm² 50 kVA Earth terminal M 10 x 20 The transformer also comprises : TED-E 16 kVA 3200 V...
Open the catalog to page 8CONNECTION INTERFACE IDR BI INTERFACE IDR BI : Epoxy resin monobloc terminal, pluggable, waterproof, single pole, lockable, to be fixed on the pit’s walls, with following characteristics: Insulation voltage: 7.2 kV Crossing current in operation 3200 V single phase: 100 A This terminal consists of eight, single pole plug-in inputs allowing equally the functions of the input line, output or deviation line, deviation towards TEE or TED-E transformers, absence of voltage test (VAT) as well as earthing and short circuiting. On request : : this VAT cabinet can be equipped with a devices used only...
Open the catalog to page 9ANNEX EQUIPEMENTS SPECIFIC MAINTENANCE TOOLS: The operation key CMB for a two- pole plug allow extraction of male plugs and placing of earthing plate, with the help of a safety manipulating rod. Operation key CMB The earthing and short circuiting plate PMCB, manipulated with a safety rod, must be used only after extraction of the male two pole plug. Earthing and short circuiting plate PMCB EQUIPMENT TO INSULATE THE UNPLUGGABLE BBM male two pole plug can be used to insulate any one of the four IDR inputs. BBF female two pole plug can be used to insulate two single pole plugs, thus leaving an...
Open the catalog to page 10MAINTENANCE ACCESSORIES Maintenance operations for all MODULOBLOC systems must conform to NF C 17-200 standards using the following accessories. Maintenance procedure is fully described in AUGIER’S brochure «Maintenance of Modulobloc 5500 V networks». The electric voltage detector with sound signal is delivered in a special protection box supplied with extensions and batteries. The safety manipulating rod is used for all operations and is telescopic. The earthing clamp is attached to one part to the earthing strap, and another to the nearby earth circuit. The 1.5 metre-long earthing strap...
Open the catalog to page 11MODULOBLOC TRI RANGE Electrical modular equipment comprising the 5500 V three-phase networks The range of MODULOBLOC products consist of TEE ou TED-E transformers, IDR tri connection interfaces and annex equipment. EXAMPLES : Three-way three-phase deviation MODULO tri system with 5 kVA single phase transformer. Two -way three -phase junction allowing existing networks to conform to safety regulations. Three -way derivation with two 5 kVA transformers. All above sets have a checking compartment for absence of voltage test (VAT) and carrying out earthing and short circuiting for safety...
Open the catalog to page 12SINGLE-PHASE TEE TRANSFORMER (1 to 6 kVA) SINGLE - PHASE TRANSFORMER TEE FOR A THREE -PHASE NETWORK MV cords L = 1.5 ml with plug / IDR prepared 1x 6 mm² + shield The transformer is immersible epoxy resin monobloc, dry type with the following characteristics: Coupling : Single phase Primary voltage : 5500 V Secondary no load voltage : 237 V Insulation voltage : 7.2 kV Power rating : 1, 2, 3, 4, 5, 6 kVA Power output rating* : 1.6; 2.4; 3.2; 4; 4.8 kVA Earth terminal M 10 x 20 MV fuse terminal H Thermal probe cable HO 7 RNF 2 x 1.5 mm² L = 1.5 ml l L This transformer also comprises: Medium...
Open the catalog to page 13All Augier catalogs and technical brochures
-
TED TRANSFORMER
28 Pages
-
TER TRANSFORMER
24 Pages
-
DIAM 4100
8 Pages
-
Switch Over
8 Pages
-
Marklight work area marking
8 Pages
-
Marklight
8 Pages
-
CDE 12/13 cells
8 Pages
-
Sub-stations
24 Pages
-
DIAM 3100
8 Pages
-
DIAM 4000
4 Pages
-
MHV dimmer
4 Pages
-
TSE transformer
4 Pages
-
COMPACTO
12 Pages
-
OPTIMOFLUX
8 Pages
-
COMPACTO TT IP68
8 Pages
-
Dry transformer
8 Pages
-
Power transformer
4 Pages
-
Augier-Box
4 Pages