1. Catalogs
  2. Augier
  3. Long Distance distribution in Medium Voltage HTI (3200 or 5500 V)

Long Distance distribution in Medium Voltage HTI (3200 or 5500 V)

Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V)
1 / 12 PagesView full catalog

Long Distance distribution in Medium Voltage HTI (3200 or 5500 V)

Product catalog summary
Introduction
This document addresses the challenges of low voltage (LV) limitations in lighting projects, particularly for roads, motorways, and large sites. It proposes solutions using medium voltage (MV) technology to overcome these constraints.

Specifications and Solutions
The document outlines the limitations of LV sources, which are often unavailable near lighting courses, and suggests using a single electrical source with energy transport at 3200V or 5500V. This approach is suitable for extra-urban street lighting projects and can be implemented from existing LV or high voltage (HV) sources.

Examples and Case Studies
Several examples illustrate the application of MV technology:
  • Example 1: Road lighting using a 3200V single-phase network over 4500 meters.
  • Example 2: Road lighting with an exchanger using a 3200V network with multiple output feeders.
  • Example 3: Motorway lighting with a 5500V three-phase network over 22,000 meters.
  • Example 4: Great site lighting using a 5500V three-phase network.


Technical Considerations
The document discusses the feasibility of transporting HV along courses, the costs involved, and the management of administrative formalities. It emphasizes the autonomy and cost-effectiveness of MV solutions, which can reduce budgets by 15-30% and allow for future extensions and energy savings.

Equipment and Installation
Augier SA provides design and manufacturing services for step-up and step-down cabinets, transformers, and cables. The MV sources (3200V or 5500V) are transported by adapted cables, and transformers are installed near lighting columns to restore LV voltage.

Energy Saving and Management
The document highlights the potential for energy savings of 30-50% through the use of voltage variation/regulation devices and remote control systems (STEP) for monitoring and managing the MV networks.

Conclusion
Augier SA offers certified solutions for MV networks, providing autonomy, cost savings, and flexibility for lighting projects. The company is ISO 9001 certified and offers additional solutions for 950V networks.
See more

Catalog excerpts

Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -1

Do electrical constraints preventyou to achieve your lightingprojects such as roads,motorways, sites ? Are you stopped by LowVoltage limits ? YOURS CONSTRAINTS : No availability of electrical sources closed to the course to light ; the lowvoltage is quickly limited OUR SOLUTIONS : Only one electrical source and one energy transport in 3200V or 5500V. > 60 11381 - 31/05/07 size="-2">

 Open the catalog to page 1
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -2

FROM LV EXISTING ELECTRICAL SOURCES : Transport the LV to the cabinets Long distance > LV cabinetLV cabinet LV cabinet LV source LV source Crossing ofproperty HV Source > FROM A HV ELECTRICAL SOURCE : creation of a HV and LV network >

 Open the catalog to page 2
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -3

HV source LV source HV source HV/LV transformer > Rest area LV cabinetLV cabinet LV cabinet

 Open the catalog to page 3
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -4

From only one Low Voltage (400 V) or High Voltage (20 KV)electrical source , we advise you to create a MV voltage which allows the energy distribution along the course on average and long distan-ces (from 2 to 20 Km). > We study with you and for you all the design of the step-up or step-down cabinet. We are a manufacturer of this kind of systems MV sourcesӔ: 3200 or 5500 V. This Voltage is transported by adapted cable (6 kV). Transformers burriedclosed to the lighting column restore the LV voltage 230 V or 400 V.We produce those transformers, real step-down mini-station˻.Thosecable and transformers...

 Open the catalog to page 4
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -5

150 lamps of 250 W SHP PTC outdoor3200 VSingle phase LV cable2 X 10 mmTransformers 3200 V / 230 V 3 kVACable 3200 V1 x 16 + 16 mmҲPTM Indooror step-down station400 V Three phase or 20 KV LV Cable2 X 10 mm Transformers3200 V / 230 V3200 V cable1 x 10 +10 mmҲ 25 250 kVA3200 VSingle phase >

 Open the catalog to page 5
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -6

Cable LV 2 x 10 mmTransformers5500 V/ 230 V5 kVACable 5500 V3 x 25 mmҲMain station800 kVA equipped 366 lamps 2 x 250 w 20 kV 5500 VThree phase > 5500 VThree phaseCable 5500 VCable LV Access road 2000 m2 x 10 mm Inner roadSite road 4500 m20 kV Three phaseTransformers andVariator400 kVA >

 Open the catalog to page 6
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -8

Simplified cabinetPTS 32 Modular substation PTMSwitchboard 5500 V Power transformer ModuloblocTEDTEC Compact minisubtation PTC >

 Open the catalog to page 8
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -10

The STEP is a remote control and (or) monitoring system by power carrierline technology on the MV networks. Advantages: No additional cables, the controls are choosen by the owner. Aim : To light on and off each part onrequest. Transformation main station On thenetwork Remote controlMonitoring > E. SourceTransformerMV swithboardControl cabinet MV + power carrierlineEmitter and receiver unit Circuit breaker+ Contactor+ Receiver(R) Transformer (T) +Coupling device (C)TTCCRR size="-1">

 Open the catalog to page 10
Long Distance distribution in Medium Voltage  HTI (3200 or 5500 V) -11

Remote control / si g nallin g of the network : the STEP > The coupling device allows the order or information transmission from the LV toMV network and inversely. The coupling deviceThe emitter unit The indoor coupling device The receiver unit On the network, 2 types of coupling device :-Coupling device installed in the transformer-Coupling device independent of the transformerThe outdoor coupling device TCRR TEDCubicle A / B : - 1 lamp on 2,- 2 indoor, 2 outdoor, - Columns with many lamps ...Lamps size="-1">

 Open the catalog to page 11

All Augier catalogs and technical brochures

  1. TED TRANSFORMER

    28  Pages

  2. TER TRANSFORMER

    24  Pages

  3. DIAM 4100

    8  Pages

  4. Switch Over

    8  Pages

  5. Marklight

    8  Pages

  6. Sub-stations

    24  Pages

  7. DIAM 3100

    8  Pages

  8. DIAM 4000

    4  Pages

  9. MHV dimmer

    4  Pages

  10. COMPACTO

    12  Pages

  11. OPTIMOFLUX

    8  Pages

  12. Modulobloc

    20  Pages

  13. Augier-Box

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.