PRODUCT LEAFLET DRY TYPE TRANSFORMER Single-phase, three-single, three-two and three-phase transformers 1.1 kV to 7.2 kV classes
Open the catalog to page 1Dry Type Transformers Transformers meant to be installed in a dry and air conditioned room or in a PTI AUGIER type substation. ELECTRICAL CHARACTERISTICS : Power rating and type : Single-phase : TMAI : 5 - 7.5 - 10 - 16 - 25 - 32 - 50 kVA Three-single : TTMAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-two : TTBAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-phase : TTAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages...
Open the catalog to page 2CONSTRUCTION : Magnetical circuits with crystal made sheet metal, oriented, with low losses. Copper or aluminium windings, impregnated vacuum with a fungicide varnish, class H impregnation. Metallic flanges. Ironed chassis with rollers. Wooden terminals plate bakelised. Cooling Use Color : in natural air : NA. : use in dry, air conditioned rooms, at a room temperature of -15 °C ; + 40°C. : RAL 7035 gray. STANDARDS AND TESTS : Conforms to NFC 17200 - NFC 52100 - CEI 76 standards. Other specifications on request. Routine tests U.T.E made on each transformer, specific tests on request.. Dry...
Open the catalog to page 3Three-phase dry Type Transformers TTAI ELECTRICAL CHARACTERISTICS : Power rating: 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 - 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Step-down Dyn11 - Step-up YNd1, other couplings on request. CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the...
Open the catalog to page 4TTAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME - STEP DOWN TRANSFORMER Power rating (kVA) SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE - STEP DOWN TRANSFORMER Power rating (kVA)
Open the catalog to page 5Single-phase Dry Type Transformers TMAI ELECTRICAL CHARACTERISTICS : Power rating: 5 - 7,5 - 10 - 16 - 25 - 32 - 50 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V. Secondary load voltage : 230 V - 950 V - 3200 V. Couplings : Standard : single-phase transformer : Ii0 CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % ou +- 5%...
Open the catalog to page 6TMAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME Power rating (kVA) SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE Power rating(kVA)
Open the catalog to page 7A WORLD OF ENERGY UNDER CONTROL UN MONDE D'ENERGIE MAITRISEE
Open the catalog to page 8All Augier catalogs and technical brochures
-
TED TRANSFORMER
28 Pages
-
TER TRANSFORMER
24 Pages
-
DIAM 4100
8 Pages
-
Switch Over
8 Pages
-
Marklight work area marking
8 Pages
-
Marklight
8 Pages
-
CDE 12/13 cells
8 Pages
-
Sub-stations
24 Pages
-
DIAM 3100
8 Pages
-
DIAM 4000
4 Pages
-
MHV dimmer
4 Pages
-
TSE transformer
4 Pages
-
COMPACTO
12 Pages
-
OPTIMOFLUX
8 Pages
-
COMPACTO TT IP68
8 Pages
-
Power transformer
4 Pages
-
Modulobloc
20 Pages
-
Augier-Box
4 Pages