PRODUCT LEAFLET DRY TYPE TRANSFORMER Single-phase, three-single, three-two and three-phase transformers 1.1 kV to 7.2 kV classes
Open the catalog to page 1Dry Type Transformers Transformers meant to be installed in a dry and air conditioned room or in a PTI AUGIER type substation. ELECTRICAL CHARACTERISTICS : Power rating and type : Single-phase : TMAI : 5 - 7.5 - 10 - 16 - 25 - 32 - 50 kVA Three-single : TTMAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-two : TTBAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-phase : TTAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above....
Open the catalog to page 2CONSTRUCTION : Magnetical circuits with crystal made sheet metal, oriented, with low losses. Copper or aluminium windings, impregnated vacuum with a fungicide varnish, class H impregnation. Metallic flanges. Ironed chassis with rollers. Wooden terminals plate bakelised. Cooling Use Color : in natural air : NA. : use in dry, air conditioned rooms, at a room temperature of -15 °C ; + 40°C. : RAL 7035 gray. STANDARDS AND TESTS : Conforms to NFC 17200 - NFC 52100 - CEI 76 standards. Other specifications on request. Routine tests U.T.E made on each transformer, specific tests on request.. Dry type...
Open the catalog to page 3Three-phase dry Type Transformers TTAI ELECTRICAL CHARACTERISTICS : Power rating: 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 - 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Step-down Dyn11 - Step-up YNd1, other couplings on request. CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer....
Open the catalog to page 4TTAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME - STEP DOWN TRANSFORMER Power rating (kVA) SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE - STEP DOWN TRANSFORMER Power rating (kVA)
Open the catalog to page 5Single-phase Dry Type Transformers TMAI ELECTRICAL CHARACTERISTICS : Power rating: 5 - 7,5 - 10 - 16 - 25 - 32 - 50 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V. Secondary load voltage : 230 V - 950 V - 3200 V. Couplings : Standard : single-phase transformer : Ii0 CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % ou +- 5% sorties...
Open the catalog to page 6TMAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME Power rating (kVA) SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE Power rating(kVA)
Open the catalog to page 7A WORLD OF ENERGY UNDER CONTROL UN MONDE D'ENERGIE MAITRISEE