DIAM 4100
1 /8Pages

DIAM 4100

DIAM 4100
1 /8Pages

Catalog excerpts

DIAM 4100-1

PRODUCT LEAFLET DIAM 4100 Single-phase Constant Current Regulator

 Open the catalog to page 1
DIAM 4100-2

Compliance Standards ICAO Aerodrome design manual, part 5 Annex 14 IEC (61822) FAA (AC150/5345-10G – L829 - L828) AENA (PPT002 ed4-2004) Applications DIAM4100 series CCRs are optimized static devices, controlled by two thyristors, designed to maintain a constant, pre-displayed and adjustable output current independently of load or power supply fluctuations. These devices are specifically designed for airfield lighting on runways, taxiways or aprons. They meet all international standards. DIAM4100 type CCR differs from the DIAM4000, (from which it takes all the electro technical and electric power...

 Open the catalog to page 2
DIAM 4100-3

DIAM 4100 : Technical Characteristics GENERAL PRESENTATION Each DIAM4100 is delivered into a metal frame with lifting rings. It includes 3 distinct parts: an "electronic" compartment, a “Low voltage” compartment and a "high voltage" compartment. The Electronic part includes an electronic board whose design uses the lastest digital technologies; it is fixed at the front panel of the device. This front sheet supports the user interface delivering any useful information, and allowing all local or distant operations. Internal parts are accessible from the front or the top. The Low voltage compartment...

 Open the catalog to page 3
DIAM 4100-4

DIAM 4100 : Technical Characteristics PROTECTIONS Lightning arrestors on outputs or input (option) Input circuit breaker instead of fuse (option) Overcurrent, Open circuit, Under/Over input voltage. USER INTERFACE Made up of a flat polyester keypad on the front plate, it includes a wide display of 16 x 140 p. with screen saver , showing preferably on the upper line the installation state, warnings and parameters, and on the lower line the 4 keys definition, depending of the present menu. An USB front socket allows the connection of a laptop computer, for a parameter setting possible without live...

 Open the catalog to page 4
DIAM 4100-5

DIAM 4100 : Display and Menus DISPLAY FUNCTIONALITY The display shows 2 lines of text allowing to monitor many parameters, values and warnings. The lower line sets the definition of the keypad. The preferred information displayed can be changed in “STOP” mode, and can be chosen (long press on STOP) among the following possibilities : “Output current Io” – “brightness state Bx” “Output current Io” – “Output power Po” “Output current Io” – “Output voltage Uo” DISPLAY EXAMPLES AND KEYS DEFINITION : “Stop” mode: “Local” mode : (B5 level). Press B+ or B- to increase / decrease the brightness : “Remote...

 Open the catalog to page 5
DIAM 4100-6

DIAM 4100 : Display and Menus CONFIGURATION MENU The “Configuration” menu allows to set all basic parameters of the CCR to the processor (in case of mother board replacement, for example) : Rated input voltage, from 208 to 480 Vac Rated power, in kVA, from 1 to 30 kVA Brightness steps, from 1 to 8. Type : FAA or IEC OPTION MENU The “Option” menu allows the following definitions: Parameter access: No A change from No to Yes allows the modification of all parameters of the DIAM4100, in order to avoid wrong operations. Scrolling items, all optional features of the CCR can be shown. SETTING MENU...

 Open the catalog to page 6
DIAM 4100-7

Constant Current Regulator - DIAM 4100 ORDERING INFORMATION The DIAM4100 regulator is identified by a serial ordering code which indicates its type and particularity. If needed, add all useful precision and options. Example : D41-IEC-1-5-50-15-400-B21-530 = DIAM4100 compliant to IEC, 6.6A, 5 brightness, 50Hz, 15kVA, 400Vac, with a multiwire interface (dry contacts) ,Jbus serial network, lightning arrestors on output terminals, Circuit breaker, EFD and LFD. IEC : IEC type 828 : L-828 FAA Type (options as described in L828 advisory are included) 829 : L-829 FAA Type (options as described in L829...

 Open the catalog to page 7
DIAM 4100-8

A WORLD OF ENERGY UNDER CONTROL UN MONDE D'ENERGIE MAITRISEE

 Open the catalog to page 8

All Augier catalogs and technical brochures

  1. TED TRANSFORMER

    28  Pages

  2. TER TRANSFORMER

    24  Pages

  3. Switch Over

    8  Pages

  4. Marklight

    8  Pages

  5. Sub-stations

    24  Pages

  6. DIAM 3100

    8  Pages

  7. DIAM 4000

    4  Pages

  8. MHV dimmer

    4  Pages

  9. COMPACTO

    12  Pages

  10. OPTIMOFLUX

    8  Pages

  11. Modulobloc

    20  Pages

  12. Augier-Box

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.