Catalog excerpts
ERGONOMIC MECHANICAL FIXTURE
Open the catalog to page 1Specialist fixture solutions Fixture assembly Innovative level mechanism Fixture configurator Mechanical standalone fixture Available housing types Mechanical exchangeable cassette system Available housing types Spare parts for the MMI-Series Imprint Publisher: ATX Hardware GmbH West Am Kornfeld 8 86932 Pürgen Germany Phone +49 8196 9304-0 Telefax + 49 8196 9304-19 E-Mail: projekte@atx-hardware.de Website: www.atx-hardware.de
Open the catalog to page 2SPECIALIST FIXTURE SOLUTIONS ATX is Europe´s market leader in the manufacture of test fixtures for electronic test procedures. Why you too should choose an ATX fixture - it´s simple: TECHNICAL KNOW-HOW PROJECT KNOW-HOW KNOWLEDGE BASE Our sales team is technically well We work together with you towards a Our employees bring well over versed - our consultants are selected common goal: to find and implement 1,000 man-years of fixture buil- from the design team or other tech- the optimal solution for your individual ding experience to the team. nical departments. testing requirements. SINCE...
Open the catalog to page 3INNOVATIVE LEVER MECHANISM HIGHLIGHTS · Maximum ease of use · Ergonomic · Robust & durable A NEW CONCEPT IN A NUTSHELL The MMI is optimally adjust to the operator The MMI is the reliable ergonomic, mechanical fixture system developed by ATX. With our new design, we adapt perfectly to the interaction between man and machine. This property was also the inspiration for the name: Man Machine Interface Its new lever mechanism, which has been filed as a utility patent, is specially adapted to the movement of the human hand and enables lightweight, ergonomic work for the operator. The all-new...
Open the catalog to page 4MECHANICAL STANDALONE FIXTURE MMI - MAN MACHINE INTERFACE Standalone Fixture With the MMI from ATX, you have the ideal fixture solution for function test, final test and ICT applications for up to 1600 N (approximately 800 needles á 2 N). Our new system combines optimal ergonomics with high performance, durability and precision, ensuring your investment over the long term. The new mechanism allows free access to the moving plate, because on the frame plate there is no front structure. We facilitate the operator in loading the test object. Through the precentered hold-down plate a more...
Open the catalog to page 5MECHANICAL STAND ALONE FIXTURE STANDARD - 1200 N (MAX. 600 PROBES Á 2 N) Designation Standard housing Order number SPECIAL HEIGHT - 1200 N (MAX. 600 PROBES Á 2 N) Designation Standard housing Order number Standard housing Order number AMPLIFIED - 1600 N (MAX. 800 PROBES Á 2 N) Designation TANDEM FIXTURE WITH 2 MECHANISMS IN ONE HOUSING Designation MMI-A-DO* Standard housing Order number All fixtures marked with * are also available with a high housing.
Open the catalog to page 6AVAILABLE HOUSING TYPES FOR MMI TO FIT FLEXIBLY INTO YOUR TEST ENVIRONMENT Housing with back panel (connectors can be mounted as required) 300 Standard housing for MMI-A Standard housing for MMI-GV Standard housing for MMI-L Light High housing for MMI-L Light Standard housing for MMI-B, MMI-BV High housing for MMI-B, MMI-BV Standard housing for MMI-C, MMI-A-DO, MMI-CI, High housing for MMI-C MMI-A-DO, MMI-CI, MMI-CH, MMI-CV
Open the catalog to page 7AVAILABLE HOUSING TYPES FOR MMI TO FIT FLEXIBLY INTO YOUR TEST ENVIRONMENT Housing with back panel (connectors can be mounted as required) 650 Standard housing for MMI-D, MMI-DV High housing for MMI-D, MMI-DV Standard housing for MMI-E POSSIBILITY OF MOUNTING AN INTERFACE ON THE REAR WALL The GFK-Aperture is installed in our test fixtures as standard. All other interface mounting options can be ordered with or without the respective interface. Interface Housing The E01-00032 housing has a vacuum interface for „Teradyne Spectrum 8855“ in the bottom of the housing. The assignments shown above...
Open the catalog to page 8MECHANICAL EXCHANGEABLE CASSETTE SYSTEM MMIW2 - MAN MACHINE INTERFACE EXCHANGEABLE CASSETTE SYSTEM Compact, ergonomic MMIW2 exchangeable cassette system with Top Loader function The new MMIW2 mechanical exchangeable cassette system consisting of the MMIWG2 basic unit and the MMIWK2 cassette provides you with even more convenience and efficiency. In your testing centre the low-cost cassette solution based on the MMI mechanism is ideal for frequently changing products. In switching between products you save time because no tools are required, while also benefiting from minimal maintenance...
Open the catalog to page 9MECHANICAL EXCHANGEABLE CASSETTE SYSTEM BASIC UNIT WITH STANDARD HEIGHT Designation Standard housing Order number EXCHANGEABLE CASSETTE - STANDARD 1200 N (MAX. 600 PROBES Á 2 N) Designation Interface block Order number EXCHANGEABLE CASSETTE - AMPLIFIED 1600 N (MAX. 800 PROBES Á 2 N) Designation Interface block Order number All fixtures marked with * are also available with a high housing.
Open the catalog to page 10MECHANICAL EXCHANGEABLE CASSETTE SYSTEM BASIC UNIT WITH SPECIAL HEIGHT Designation Standard housing Order number EXCHANGEABLE CASSETTE - SPECIAL HEIGHT 1200 N (MAX. 600 PROBES Á 2 N) Designation Interface block Order number BASIC UNIT - SUITABLE FOR MEWK-CASSETTE Designation Standard housing Order number Interface block Order number EXCHANGEABLE CASSETTE Desingation All fixtures marked with * are also available with a high housing.
Open the catalog to page 11AVAILABLE HOUSING TYPES FOR MMIW2 TO FIT FLEXIBLY INTO YOUR TEST ENVIRONMENT Housing with back panel (connectors can be mounted as required) Standard housing for MMI-MEWG-A High housing for MMI-MEWG-A Standard housing for MMI-MEWG-B High housing for MMI-MEWG-B Standard housing for MMIWG2-A, MMIWG-A-VPC High housing for MMIWG2-A, MMIWG-A-VPC
Open the catalog to page 12AVAILABLE HOUSING TYPES FOR MMIW2 TO FIT FLEXIBLY INTO YOUR TEST ENVIRONMENT Housing with back panel (connectors can be mounted as required) 780 E01-00132 Standard housing for MMIWG2-C, MMIWG-CH INTERFACE POSSIBILITY OF MOUNTING AN INTERFACE ON THE REAR WALL The GFK-Aperture is installed in our test fixtures as standard. All other interface mounting options can be ordered with or without the respective interface. Interface Housing The assignments shown above are standard designs. However, due to our high variety of housings, special designs can be made after consultation.
Open the catalog to page 13All ATX Hardware GmbH West catalogs and technical brochures
-
ATX COAXIAL PROBE V2.0
8 Pages
-
LED TEST
12 Pages
-
ME2-SERIES
8 Pages
-
MMIHF-SERIES
12 Pages
-
MMI-SERIES
20 Pages
-
CAPACITIVE PROBES
6 Pages
-
INTERFACEBLOCKS
16 Pages
-
FIXTURE ACCESSORIES
12 Pages
-
MEP-SERIES PNEUMATIC FIXTURE
16 Pages
-
VACUUM FIXTURE KIT
30 Pages
-
ME-SERIES MECHANICAL FIXTURE
16 Pages
-
VACUUM FIXTURE
13 Pages
-
LHS2 LINEAR ARM FIXTURE
8 Pages
-
MECHANICAL FIXTURES
8 Pages