Overview: The attoDRY800 is a cryo-optical table designed for quantum optics experiments, offering cryogenic temperatures and optical access with an integrated ultra-low vibration cold breadboard.
Specifications:
  • Technology: Ultra-low vibration, closed-cycle cryostat integrated into an optical table.
  • Sample Environment: Cryogenic vacuum with a 75 mm diameter sample space.
  • Temperature Range: 3.8 to 320 K.
  • Vibration Level: Less than 5 nm peak-to-peak at 1500 Hz.
  • Power Consumption: Maximum 3 kW with water or optional air cooling.
Key Features:
  • Cold breadboard integrated into the optical table.
  • Low vibrations (< 5 nm peak-to-peak).
  • Fully automated temperature control.
  • Customizable vacuum shroud.
Benefits:
  • Free workspace and unobstructed optical access.
  • High sample throughput due to fast cooldown.
  • Low running costs as no liquid cryogens are required.
  • Flexible integration with attocube equipment.
Applications:
  • Quantum dot spectroscopy.
  • Photocurrent/photoconductivity measurements.
  • Micro-Raman imaging and spectroscopy.
  • Quantum information processing.
Options and Upgrades:
  • Temperature controller and pumping kit included.
  • Various vacuum shroud configurations available.
  • Electrical and optical feedthrough options.
  • Customizable optical table sizes and configurations.
Performance Data:
  • Base Pressure: Less than 5e-6 mbar.
  • Leak Rate: Less than 5e-9 mbar l/s.
  • Cool Down Time: Less than 4.5 hours to 5 K.
  • Temperature Stability: Less than 15 mK peak-to-peak.
Conclusion: The attoDRY800 provides a versatile and efficient solution for cryogenic optical experiments, offering high precision and low operational costs with its innovative design and integration capabilities.
Additional Specifications:
  • Standard objective with 45 mm length; additional objectives available with NA ranging from 0.75 to 0.95.
  • Cage system mounting threads centered around the top window, available in 30 mm x 30 mm and 60 mm x 60 mm sizes.
  • Feedthrough ring with blind flanges included; optional DC/SMA/fiber feedthroughs.
  • attoDRY800 HV objective vacuum shroud designed for high vacuum compatible objectives.
  • Cold shield with adjustable top lid for minimal working distance.
  • Top vacuum window dimensions: 25 mm x 1.5 mm; cold shield top window: 12.7 mm x 0.375 mm; window material is fused silica.
  • 4x side vacuum windows measuring 40 mm x 4 mm.
  • Cold plate included.
Positioners and Thermal Links:
  • ANPxy311/ANPz102 positioners with ATC100/Si thermal link, integrated Si diode, and heater.
  • Optional ANSxy100 scanner available.
Cryogenic Apochromatic Objectives:
  • Negligible chromatic focal shift within the working range.
  • Uniform spot size and intensity within the apochromatic range.
Product Key Features:
  • Vacuum shroud for use with 2 horizontal internal LT-APO low temperature objectives.
  • Provides sufficient space for 7 degrees of freedom to independently position the sample and 2x focal spot.
  • 8 side windows for scattering and transmission.
  • Vacuum shroud for use with internal LT-APO low temperature objective and lensed-fiber probes for side illumination and detection of waveguide structures.
  • Minimal sample drift and broadband high collection efficiency.
  • Sufficient space for 9 degrees of freedom to independently position the sample, focus, and 2 fiber probes.
  • Side access with an additional window for RT optics.
Positioners for Sample and Fiber Probes:
  • ANPxy311/RES positioners for xy translation of sample and fiber probes.
  • 2x ANPxyz51/RES for xyz translation of fiber probes.
  • LT-APO objective on a separate mounting post.
  • ANPx311 for z focus of objective with thermal link for objective.
Additional Features:
  • attoDRY800 vacuum shroud for photonic probe station setup.
  • Cold shield with top vacuum window of 25 mm, cold shield top window of 20 mm.
  • Additional window for side inspection measuring 25 mm x 1 mm; window material options include fused silica or N-BK7.
  • Customized vacuum shrouds available for transmission with two LT-APO objectives or free-beam access from 5 sides with low working distance.
See more

Catalog excerpts

attoDRY800-1

WITTENSTEIN Group WITTENSTEIN Group attoDRY800 © 2018, attocube systems AG - Germany. attocube systems and the logo are trademarks of attocube systems AG. Registered and/or otherwise protected in various countries where attocube systems products are sold or distributed. Other brands and names are the property of their respective owners. attocube systems AG | Königinstrasse 11a | D - 80539 München | Germany Tel.: +49 89 2877 809 - 0 | Fax: +49 89 2877 809 - 19 | [email protected] www.attocube.com Brochure version: 2018 - 01 Cryo-Optical Table

 Open the catalog to page 1
attoDRY800-2

cryo-optical table (closed-cyde) Quantum optics experiments often require cryogenic temperatures in combination with optical access to the sample space. Most experimental setups contain numerous optical elements that need to be precisely arranged on an optical table to shape and prepare the incident light, as well as to efficiently collect and convert the emitted light from the sample. The available space on the optical table in such cases is of paramount importance to many complex setups. The revolutionary concept and design of the attoDRY800 present the perfect solution to satisfy these demanding...

 Open the catalog to page 2
attoDRY800-3

Decide on the table size Customized Newport optical tables with metric M6 or imperial hole pattern are available with the following dimensions : (other table sizes and solutions for integration with existing optical tables available on request) Add multiple degrees of freedom for sample motion The attoDRY800 is predestined to host your choice of nanopositioners, be it linear, rotary, tilting or scanning stages. Combine many degrees of freedom, or more than one stack of positioners to fulfill all requirements of your application! With our dedicated ATC100 thermal link, we ensure a perfect thermalization...

 Open the catalog to page 3
attoDRY800-4

attoDRY800 Vacuum Shrouds introduction The idea behind the world‘s first cryo-optical table is that the user receives a high quality optical table from of his choice, which has an integrated cold plate of 75 mm in diameter. The cryostat is an integral part of the table, and comes in a standard configuration. The position of this cold plate can be chosen upon order. shrouds and cold shields, that are intended for certain types of positioners, sample holders, working distances and objectives. These options constitute an economic pre-configured set of components that give the user a head start for...

 Open the catalog to page 4
attoDRY800-5

Basic (Standard Shroud) version version RT-SWD (RT-USWD) basic vacuum shroud for use with a room temperature objective vacuum shroud for use with room temperature objective and positioners • included with attoDRY800 base configuration at no additional cost!* • corresponds to the classical flow cryostat configuration • 88xM6 breadboard mounting holes • compatible with 30 mm & 60 mm cage system • optional sample holder with manually adjustable height, and 12 optional electrical contacts • feedthrough ring with blind flanges included, DC/SMA/fiber feedthroughs optional • not compatible with positioners,...

 Open the catalog to page 5
attoDRY800-6

LT-APO Objective version version version version vacuum shroud for use with low temperature objective vacuum shroud for use with vacuum objectives • standard configuration for use with internal LT-APO low temperature objective and xyz positioners (+ optional scanner) • minimal sample drift, broadband high collection efficiency • compatible with 30 mm & 60 mm cage system • optional sample holder with 12 optional electrical contacts; temp. sensor & heater included • feedthrough ring with blind flanges included, DC/SMA/fiber feedthroughs optional • standard configuration for use with internal high...

 Open the catalog to page 6
attoDRY800-7

Photonic Probe Station Customized Vacuum Shrouds vacuum shroud for photonic probe station incl. optical side access attoDRY800 customized shroud for transmission with two LT-APO objectives • Vacuum shroud for use with internal LT-APO low temperature objective and lensed-fiber probes for side illumination & detection of waveguide structures • minimal sample drift, broadband high collection efficiency • Sufficient space for 9 degrees of freedom to independently position sample, focus, and 2 fiber probes • Side access with additional window for RT optics PRODUCT KEY FEATURES • Vacuum shroud for...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.